Best Answer
AnwerThe Blower motor resistor could be one of the problems if the blower only works on hi or none of the settings. Another solution could be a bad ignition switch too, since some of the wires controlling this mechanism are ran thru the ignition switch. My friend had that happen to his and mine was just the resistor pack fortunetly. So, I would check the blower motor, the resistor pack and the ignition switch. Those are the three main problems that cause this. AnswerBlown fuse, bad blower mortor, or the resistor pack is bad again. AnswerI just replaced one this week end. Fist check your fuses. If not when you disconect the fan try a new one. I believe the fan moter went out. If that doesn't fix your problemn the resister pack is right behind the fan moter. You probaly have to remove the fan to get to the resister pack anyway. Dan 913-558-7613
User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Blower resistor replaced on 2000 Pontiac Grand Prix. It fixed your problem. Now two months later the fan doesn't work on any of the settings. Is it the blower motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

On a 2000 Pontiac sunfire the heater fan has 4 settings on it and it only works on the 2 highest settings what could be my problem?

The Blower Motor Resistor Pack is defective. Replace it.


Heater fan switch not working on 1 and 2 setting on 2000 Pontiac Montana?

I just had that same problem..I took it in to have it fixed and they replaced the blower motor resistor and that seems to have fixed the problem


2004 trailblazer blower motor does not work on 123 settings but works on 4 and 5?

it needs a blower motor resistor to make the fan settings work.If you replace the Blower MOTOR Resistor it should resolve the problem.


Not sure if it is a problem with blower motor switch 2003 Pontiac Grand Prix air conditioning fan comes on intermintently.Already replaced ignition switch and pluged in new resistor and didn't help?

I had this problem with my 2002 Grand Prix where it would only work on high, and even then only worked sometimes. I had to have the whole unit replaced. It was around $400.


2002 Chevy Trailblazer why would only get heat or air when you turned the knob up to 5 now it does nothing?

I had the same problem with the 2003 except the I gradually lost one or two fan settings at a time. There is a resistor unit on the fan itself, behind and below the glove box. It was badly corroded. I replaced the resistor unit and now the fan works on 1 thru 5 settings again.


How do you diagnose a heater blower motor problem on a 2001 grand prix?

If the blower only works on high the blower resistor is most likely the problem and should be replaced. On rare occasions if the car has blown the resistor more than once the blower motor shouuld be replaced.


What is the problem in my 1998 for mondeo as the blower does not work on any settings apart from the highest?

Defective blower motor resistor pack.


My blower motor in my 98 Pontiac sunfire works when it is at the highest 2 settings but it does not work on the lower 2 settings. why is this?

My first guess would be the blower motor speed resister. The second guess would be the switch and/or switch plug. I agree, It's a very common problem, the resistor goes for about $52.00 Can. Carquest has them part # RU44


2000 Chrysler Sebring convertible fan only works on high I replaced the resistor it still only works on high if the switch is faulty would this be the cause of the problem or something else Thanks?

I had the same problem with the same year car. I've replaced the resistor several times. It works for months & then it stops working again. I think this is the 4th time I replaced the resistor, it is working okay now. I think it is a defect in with this cars fan system. I had a similar problem with my 2001 Sebring Convertible. I had the blower motor replaced, and now the fan works perfectly.


2001 grand prix blower motor quit Replaced resistor module and fan works on high but lower speeds still short out drl module switch Fuse box connections check out ok tried 3rd resistor still broke?

I have a 2001 GTP and just replaced the ignition wiring harness - $129 part from dealership to fix same problem. Now the AC blows on 1-4 + 5 settings. Hope this helps! CIII


Where can I get my Pontiac brakes replaced cheap?

The best place I've found to get your brakes replaced is the local muffler man. Any type of smaller garage in your area will be able to take care of your brake problem at a fraction of the cost of taking it to the Pontiac dealership.


Your 2002 Pontiac Grand AM ONLY blows air when it is on the highest setting what could be the cause of this?

Typically a relay or resistor. But could be a blower switch or blower motor problem.