No, they will not fit. You can use Westinghouse, Cutler Hammer BR series, and Connecticut Electrical UBITBC series breaker. All of those will fit.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you use a Murray breaker in a Bryant panel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you use any other brand of circuit breaker in conjunction with a Challenger circuit breaker?

A Murray or similar breaker would work but most inspectors want the brand breaker to match the brand panel.


What circuit breaker is interchangeable with Bryant?

To answer this question the type of breaker you want to exchange needs to be stated, bolt in or plug in.


What size breaker do you use for a 100 amp sub panel?

A 100-A sub-panel would be fed from a 100-A breaker.


Will GE breakers fit a Murray panel?

No, they will not work. Use only Murray breakers for safety.


What circuit breakers will interchange with Murray panel?

Legally, you must use the same brand breaker with the brand panel. They sell Murray breakers at your area electrical contractor shop, but used I am sure. However, square d homeline, siemens ite, GE, cutler hammer BR do fit but will void the UL listing and are dangerous to mix. Upgrade your panelboard. It is old.


Are ge breakers compatible with a Murray panel?

In my experience, NOTHING is compatible with a Murray panel. Others claim there are certain Siemens and Federal Pacific breakers or Eaton type "CL", but you might have to obtain permission from the inspector to use anything other than Murray.


Do you need to use some type of mini breaker panel with a single 15A circuit breaker to connect a 15A receptacle into a 30A line?

To be short...Yes


Can a 100 amp main have 2 50 amp breakers?

Yes.Additional InformationBreakers and fuses protect the wires to prevent fire. The 100 Amp breaker in the meter base (main) protects the wire from the meter base to the breaker panel. The 50 Amp breaker in the breaker panel protects the wire from the breaker panel to the outlet. Sometimes the 100 amp main breaker is located in the panel.If you are asking "Can you use two 50 amp breakers for the main breakers with a 100 amp service, then yes you can. The National Electrical Code allows you to use up to 6 breakers as the main overcurrent protection.


What breaker can I use if I dont have a westinghouse breaker?

The Cutler Hammer BR series will fit and also the Connecticut Electric UBITBC series will fit your Westinghouse service panel.


What kind of breaker would you use for a 220 hook up?

In North America a two pole breaker will be used in the distribution panel for a supply of 240 volts for a 240 volt load.


What does QP on a square D breaker stand for?

A QP type breaker is made by Siemens for a Siemens distribution panel and should not be interchanged with Square D. A Siemens QP type bolt in breaker will bolt into a SQ distribution panel but it is up to the electrical inspector to make the call as to it being safe or not. Square D breaker types are QO and QB. You might be mistaking the QP for a QB on the breaker. The QO breaker is a plug in breaker usually used in home wiring and the QB is a bolt in breaker. QB breakers are usually specified for industrial and commercial use.


How do you install a 110v receptacle from a 3 phase breaker box if there are no neutrals in the breaker box?

If there is no neutral available you cannot, unless you use an autotransformer and derive a neutral. A panel with no neutral is called a power panel and is used to supply 240 single and three phase loads.