Q: Do you use 20 amp breakers from your house to feed 20 amp breakers in your garage panel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you tap meter and feed panel in detached garage?

No. Any connections to the detached garage have to be after the main disconnect of your house panel. You have two options here. You can replace meter with a meter disconnect combo and have the main feed your house and add a breaker to feed the garage or You could install a 400 ap service and place two disconnects at the meter. one for the house and one for the garage. unless you are going to have a serious electrial load in the garage you sould just feed off the panel in the house for cost effectiveness.


Can more wires be ran from the meter base to supply a shop from your house?

No, you cannot put but one set of wires in a meter base. The way to go about this, is to mount an outside panel beside your meter base. Panel sized to existing house service, equipped with two main breakers. One to re-feed the house panel the other to feed your shop.


Why would your power go out to your garage but not to your house and no fuses be blown?

Does the garage have a separate breaker box or fuse box inside? Is there a separate power feed for the garage? In the 70's and 80's some cities were allowing aluminum wiring INSIDE residences. If the wire from the main fuse/breaker panel is aluminum there is a real possibility that you might have a bad connection between the fuse box or breaker panel and the outlets in the garage.


How do you power a 50 amp kiln in your garage?

By supplying it with a 50 amp feed from your main distribution panel.


Can 100 amp distribution panel feed a 70 amp sub panel?

Yes they can. As long as the total load of all subs does not exceed the rated capacity of the main breakers, you should be fine, including 80 percent de-rating of any constant loads.


What is the place in the home that contains the circuit breakers?

The ciruit breaker box. This is usually mounted near the main power source in the home. Try the basement, the back porch, or near the kitchen. If all else fails, go outside and look where the power meter is. The breaker box should be nearby inside the home. In many homes the electrical panel is in the basement. In homes that do not have basements the electrical panel is placed in the garage.


What does micheal feed skellig?

happy


What are breakers?

A breaker is a device that is used to connect and disconnect the buss bars of an electrical panel to the feed end of wires that feed an electrical load. The function of a breaker is to protect the wires from an overload by the use of an internal thermal trip, and to protect the load and wires from a short circuit by use of an internal magnetic trip.


I have a Transformer 480 primary 208 secondary feeding 1 200amp mb 42 space panel I need to feed a subpanel 6 ft away I'm thinkin feed through lug at top of bus or at feed through MB suggestions?

The sub-panel need to be fed from the main panel, by way of a circuit breaker connected to one of the breaker locations. Or if your sub-panel has a main breaker installed you can feed from the main panel with a sub-feed lug kit. This looks like a breaker, but is only a point where you can branch off the sub panel.


Can you feed a 60 amp sub panel from another 60 amp sub panel?

Yes


Is a circuit breaker better than a glass fuse?

Each device has its own special use. Glass fuses can protect circuit at very low amperages. They are usually used to protect printed circuit boards and control panel circuits. Breakers protect circuits from short circuits and overloads. These devices are used in service distribution panels to protect the wires that feed the loads. Circuit breakers can be from 15 amps up into the thousands of amps.


Will a 100 amp breaker box work if there are 5 220 amp breakers and 7 110 breakers?

It will if the 100 amp distribution board is a 20 circuit board. Ten spaces for the 240 volt breakers and seven spaces for the 120 volt breakers. There are two types of 100 amp breaker boards, one rated at 100 percent and the other at 80 percent. Depending on what rating on the panel board you are using will govern the maximum amount of current that can be legally drawn from the board. This breaker board rating will also govern the size of the main breaker installed and the wire size to feed the board, either 100 amp wire or 80 amp wire. The second consideration is what are the connected loads to the breakers, with the total of seventeen breakers, the board can only supply as much amperage as the main breaker will allow.