answersLogoWhite

0


Best Answer

It doesn't need to be converted. The 240 Volt single-phase electricity is there already to operate any single phase devices. New breakers, the right size of wiring and a new wall outlet are what have to be installed to add a new single phase 240 Volt circuit to an existing breaker panel which already has a three-phase supply. For safety reasons only a trained and licensed electrician should work with this equipment. <><><> Careful! The statement above can be misleading. The Asker is obviously not from the US, he thinks US 240V is three phase, when its really single-phase. But note that he wants to convert to single-phase with one hot and one neutral. This is consistent with European standards with 230V single-phase where one wire is hot and one wire is cold (neutral). You cannot connect a European 230V appliance directly to US 240V because this would connect a hot wire to the appliance's grounded connection, potentially making the chassis components hot! So, while it is true nothing needs to be done to convert US 240V service to single-phase (because it already is), it is not correct to imply that US 240V can be used where you want 240 volts with one hot and one neutral. This would require an isolation transformer or other approved international voltage converter. For more information see the answer to the Related Question Can you plug a 230V 50Hz appliance into a 240V 60Hz outlet? shown below <><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

If you do this work yourself, always turn off the power

at the breaker box/fuse panel BEFORE you attempt to do any work AND

always use an electrician's test meter having metal-tipped probes

(not a simple proximity voltage indicator)

to insure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How can I convert standard American 240 volts 3 phase to 1 phase 2 wires 1 hot and 1 neutral?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

How you can convert 1-phase voltage to 3-phase voltage and vice-vars a?

A single-phase supply is obtained between any two line conductors or between a line and neutral conductor of a three-phase supply. To obtain a three-phase supply from a single-phase source is far more difficult, and requires additional equipment.


What is average 208-230 voltage?

208V is one standard in the US for light commercial 3-phase power. It measures 208V phase to phase and 120V phase to neutral. 230 (or 240)V refers (in the US) to the common service supplied to residential. It is single-phase, with two hots and a neutral; 120-0-120. One hot and the neutral (120V) is used for receptacles and small appliances, both hots (240V) are used for large appliances, such as stoves, ovens, air conditioning, and water heater.


230V line to line a single phase?

Yes. 230V line to line is considered single phase power. The 115v half part of that is called split phase. It should not be called two phase, as it is one phase that has been center tapped and grounded at the neutral point - it is still one phase power.Answer230 V is the standard nominal voltage for residences in Europe. 230 V is the line-to-neutral voltage (phase voltage). Low-voltage distribution is by three-phase, four-wire, system with a nominal line voltage of 400 V and a nominal phase voltage of 230 V.


How do you convert 3phase connection to 2 phase?

Any two legs of a three phase system can be classed as a single phase supply.Alternative AnswerAs the above answer points out, connecting a load between any two line conductors of a three-phase supply will give you a single-phase load. But you must, of course, take into account the voltage rating of the load you wish to connect.In Europe, three-phase low-voltage distribution is normally by means of a four-wire system, comprising three line conductors and a neutral conductor, operating at 400 V (line-to-line) and 230 V (line-to-neutral).Your single-phase load's voltage rating must, of course, match either the single-phase supply's line-to-line or line-to-neutral voltages. In Europe, most single-phase loads are rated at 230 V so, for a residential three-phase, four-wire system, it is usual to obtain a single-phase supply by connecting the load between any one of the line conductors and the neutral conductor.But, if you have a non-standard, 400-V single-phase load, then connecting that load between any two line conductors will also give you a single-phase supply.


Does a toaster use a neutral phase?

There is no such thing as a 'neutral phase'. 'Live' or 'hot' conductors are called 'lines', whereas the neutralconductor is at approximately earth (ground) potential.So, a toaster would be connected between a line and a neutral conductor.

Related questions

Can you convert 415v 3 phase to 230v single phase?

415V 3 phase is the line to line voltage. The line to neutral of this supply is 230V single phase. Therefore you use one of the phases and the neutral.


How three phase line current convert in single phase?

The current is the same in the three live wires. The voltage can be described as the line voltage (phase to neutral) or the phase voltage (phase to phase) which is larger by a factor of sqrt(3). So a line voltage of 230 v corresponds to a phase voltage of 400 v.


If in the three phase connection phase to phase voltage is 400v what will be the phase neutral voltage?

The formula to use is, phase voltage /1.73 = phase to neutral (ground) voltage.CommentThere is no such thing as a 'phase to phase', or 'phase to neutral' voltage. The correct terms are 'line to line' and 'line to neutral'. So the above answer should read: line voltage/1.73= line to neutral voltage = phase voltage.


Convert single phase to three phase formula?

I'm not sure what your question means as a single phase supply is normally one of the phases and the return/neutral, not all 3 phases converted to one, plus return.


How do you convert line current to phase current?

The current is the same in the three live wires. The voltage can be described as the line voltage (phase to neutral) or the phase voltage (phase to phase) which is larger by a factor of sqrt(3). So a line voltage of 230 v corresponds to a phase voltage of 400 v.


What is the code ruling in the US on 3 phase branch circuits and the neutral?

A three phase system will have 3 phase branch circuits and no neutral.


Is there a neutral on a three phase transformer?

It depends on whether you are wye or delta connected. A transformer is a transformer, and a three phase transformer is simply three transformers. The key is in how you hook them up.AnswerIt depends on how the transformer is connected. If one set of windings is connected in star (or wye), then the star point is/canbe earthed and becomes the neutral for that particular connection; this is the standard connection for the secondary (low-voltage) of European distribution transformers. In North American three-phase distribution transformers, the secondary windings are connected in delta, and one phase is centre tapped, earthed, and that becomes the neutral point for a 240/120-V split-phase supply to a residence.This answer applies to both three-phase transformers, and to single-phase transformers which have been connected to form a three-phase transformer bank. (It is incorrect to say that a three-phase transformer is simply three single-phase transformers!)


How do you tap off of a 480 volt disconnect?

You don't. You hire a qualified electrician who doesn't need to read this page for the answer. That said, if you are merely curious as to the methods: "480" Volt will be 3-phase with either Delta wiring (480 phase-to-phase, NO neutral), or Wye wiring (480 phase-to-phase, and 277 phase-to-neutral). You can use this directly, to run three phase equipment from all three phases, to run equipment at 480 from just two phases (being careful to keep loads balanced), or to run lighting circuits from the 277-to-neutral (being careful to size the neutral conductor carefully). You can also step it down to "208", which will be 208 phase to phase and 120 phase to neutral -- "standard" line voltage. But seriously, if you need to ask the question, you SHOULD NOT be touching 480 switchgear and wiring, for the safety of both yourself and others.


Why neutral cross section is half the phase in three phase cable while it has to carry current of summation of all phase..?

The current carried by the neutral of a three phase four wire system is the un balanced current. If the three phase system was completely balanced on all three phases there would be no need for a neutral, eg a three phase motor. This neutral current will be less that the phase current so a reduction in the neutral size is allowed.


What happens when phase to phase line is connected?

If there is a voltage differential from phase to phase, and a conductance (inverse of resistance) between them, then current (amperes) flows. This is no different than phase to neutral, i.e. voltage across conductance generates current, (I = EC, or I = E/A) except that neutral current is zero in a true phase to phase connection.Note that phase angle is always relative. In phase to neutral, it is relative to (typically) neutral; while in phase to phase, it is relative to the other phase. By Fourier Analysis, the difference between two phases of the same frequency, but of different phase angles, is still a sine (or cosine) wave. Also, by Kirchoff's Current Law, (implied, and I will (sort of) not repeat it here), current entering from one phase and equally leaving via another phase will not reflect at all in the neutral conductor.The simple answer is that connecting phase to phase is a short circuit, just like connecting phase to neutral.CommentThere is no such thing as 'phase to phase' or 'phase to neutral'. The correct terms are 'line to line' and 'line to neutral'.


How does a phase leg connect to a neutral in an electrical circuit?

A phase leg connects to the neutral through the connected load.


Why neutral is not requied in 3 phase?