Best Answer

You can't change the one breaker, but you can't use two separate arc fault breakers unless you separate the neutrals. However double pole arc fault breakers are made for this purpose and the common neutral would be O.K.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you change one breaker on a 3 wire that feeds two regular circuit breakers to a single arc fault circuit breaker - or do you have to change both breakers to arc fault so each has a neutral?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can you install a tandem breaker?

Tandem breakers, often called split breakers or double breakers, provide two separate circuits in the space of a regular sized breaker opening. Every circuit breaker panel has a limited number of circuit openings available. The problem is that when the openings are all used up and you still need to add another circuit, what do you do? You could change the electrical panel or double up circuits on a breaker, but this could place too much load on a particular circuit. So what then? The answer that many have found is a tandem breaker. This type breaker is the same size as any other breaker, but it has its difference. This breaker sports two smaller breakers built into one regular sized breaker. Each has its own breaker switch and the breaker snaps in just like a regular breaker. With this simple innovation, you can add a circuit and protect the circuit on its own dedicated line.


What is the cost of a miniature circuit breaker?

In the US a miniature circuit breaker, sold in a single unit, is about 15$, about the same as a regular breaker. If sold as a double unit, meaning two mini breakers installed into one housing, then it is about 25$.


Is it safe to have 200 plus amps in breakers inside than 90 amps on the main service breaker outside?

I am assuming by your description that the panel is protected by a 90 amp breaker and the breakers in the panel when added up is 200. This is okay as long as your 90 amp breaker trips on a regular basis. It is typical for the breakers to add up to more than the main breaker under the assumption that you would rarely be running each circuit at its maximum capacity.


What are the different kinds of electrical receptacle?

The most common types are the regular type, where the only over current protection is provided by the breaker panel. the other most common type is the GFCI (Ground Fault Circuit Interrupter) This type has a built in "circuit breaker" so when it senses a fault in the circuit it trips-this type is the safest as they are more sensitive than circuit breakers in the breaker panel.See related links below.


How does drawable circuit breaker look like?

in a single line diagram it looks like this ( ____/ ___ ) while regular circuit breaker looks like this ____/ ____ the difference is that the first one can be removed from its place if maintenance is needed, while the regular one you can't. Viva Palestine

Related questions

Can you install a tandem breaker?

Tandem breakers, often called split breakers or double breakers, provide two separate circuits in the space of a regular sized breaker opening. Every circuit breaker panel has a limited number of circuit openings available. The problem is that when the openings are all used up and you still need to add another circuit, what do you do? You could change the electrical panel or double up circuits on a breaker, but this could place too much load on a particular circuit. So what then? The answer that many have found is a tandem breaker. This type breaker is the same size as any other breaker, but it has its difference. This breaker sports two smaller breakers built into one regular sized breaker. Each has its own breaker switch and the breaker snaps in just like a regular breaker. With this simple innovation, you can add a circuit and protect the circuit on its own dedicated line.


What is the cost of a miniature circuit breaker?

In the US a miniature circuit breaker, sold in a single unit, is about 15$, about the same as a regular breaker. If sold as a double unit, meaning two mini breakers installed into one housing, then it is about 25$.


Is it safe to have 200 plus amps in breakers inside than 90 amps on the main service breaker outside?

I am assuming by your description that the panel is protected by a 90 amp breaker and the breakers in the panel when added up is 200. This is okay as long as your 90 amp breaker trips on a regular basis. It is typical for the breakers to add up to more than the main breaker under the assumption that you would rarely be running each circuit at its maximum capacity.


What are the different kinds of electrical receptacle?

The most common types are the regular type, where the only over current protection is provided by the breaker panel. the other most common type is the GFCI (Ground Fault Circuit Interrupter) This type has a built in "circuit breaker" so when it senses a fault in the circuit it trips-this type is the safest as they are more sensitive than circuit breakers in the breaker panel.See related links below.


How do you get four twenty amp circuits from two twenty amp circuits?

Remove the two twenty amp breakers from the regular size slot and install two mini amp breakers. A mini amp breaker has two breakers per regular size slot.


How does drawable circuit breaker look like?

in a single line diagram it looks like this ( ____/ ___ ) while regular circuit breaker looks like this ____/ ____ the difference is that the first one can be removed from its place if maintenance is needed, while the regular one you can't. Viva Palestine


How do I get 220 volt circuit?

If you need a 220v circuit at only 15 or 20 amps: Get a new breaker to replace your 110v single pole breaker with a 220v double pole breaker. (You cannot exceed the original breaker's amperage rating unless you also replace the wire with a larger size). Shut off the panel's main breaker (the wires coming into the main breaker will remain hot, so don't touch them.) Remove the old 110v circuit's neutral (white) from the neutral bus bar in your distribution panel. Remove the old 110v circuit's hot (black) from the old 110v breaker. Remove the old 110v breaker. Install the new 220v breaker in place of the old breaker. (This may require you to rearrange some breakers if the old breaker was in between others) Reconnect the black wire to one terminal of the 220v breaker, and reconnect the white wire to the other terminal. Turn on the main breaker, and your new 220v breaker. Before you do this, be sure where the actual circuit goes. Changing 110v to 220v if the circuit is feeding regular 110v receptacles will cause damage to devices plugged into them. Be sure you remove all 110v devices (receptacles) from the circuit before converting it. If you need a 220v circuit for a dryer or other large appliance, your existing wiring will not be sufficient to do the above. You will need to install a new breaker and wiring. For this task, you should consult a professional electrician.


What fuse powers the sun roof on your 1995 jeep limited?

Sunroof has a 30 amp circuit breaker, position number 26 in the fuse box on the far passenger side of the dash. This circuit breaker also powers the power windows. The circuit breaker can be pulled out and replaced just like a regular fuse.


Gould siemens elactrical breakers the same?

In many fields companies are bought and sold on a regular basis. So it is with many circuit breaker companies Siemens is the current name; previously it was ITE-GOULD; previous to that it was just ITE Some breaker models will carry through and be of the same design and fit no matter which brand label is on it. In most of those cases the model # does not change. Some breaker get obsoleted after the mergers. Sometimes new models are added.


Will cobwebs trip a breaker?

No, cobwebs alone will not trip a breaker. Breakers are designed to protect against overloading and short circuits, not cobwebs. However, if the cobwebs accumulate and cause insulation damage, it could potentially cause an electrical issue that may trip the breaker. Regular cleaning and maintenance can help prevent this.


What is the advantage of fuse over the circuit breaker?

A fuse might be a bit cheaper and the form factor may smaller if size is an issue. If the fuse blows on a regular basis it will of course end up costing more and will be more inconvenient to replace.


How can you plug in 120V appliances such as a TV and VCR to an old 240V air-conditioning outlet with one white one black and one grounding?

At the breaker box the black and white will be on a double-pole breaker (or maybe even two separate breakers). To convert to 110V attach the black to a single pole 15 amp breaker, the white to the neutral bus bar (like all the other whites in there) and the ground to the grounding bar (like the other grounds). Then replace the receptacle with a regular 15amp 110V.