Best Answer

The 4-wire cable should have black, red, white and a green or bare wire. The 220 volts is between red and black. The white is neutral or common and there would be 110 volts between white and red and between white and black. The green or bare wire is the ground.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

12y ago

This type of connection can be very dangerous. A proper double pole double throw switch must be utilised in this type of installation. This switch must be installed after the first over current device which is the main breaker in your distribution panel. Most houses today use a combination panel that consists of the main disconnect built into the breaker section. As you can visualize this would become a major installation and revamping of your distribution service equipment. An electrician should do this work as a permit will have to be taken out because the utility company has to disconnect the power by pulling the electrical meter. Back feeding a house when there is a power outage can re energize the primary voltage lines that utility workmen might be working on. There are cases of linemen being killed by generator back feeding.

This answer is:
User Avatar

User Avatar

Wiki User

12y ago

This type of connection can be very dangerous. A proper double pole double throw switch must be utilised in this type of installation. This switch must be installed after the first over current device which is the main breaker in your distribution panel. An electrician should do this work as a permit will have to be taken out because the utility company has to disconnect the power by pulling the electrical meter. Back feeding a house when there is a power outage can re energize the primary voltage lines that utility workmen might be working on. There are cases of linemen being killed by generator back feeding.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

A four wire alternator in electrical terminology is one that is connected in a three phase wye configuration. The terminal output terminals will be marked L1, L2, L3 and N as the star point. If you are referring to a three phase load as the three wire connection then the load will be connected across L1, L2 and L3.

This answer is:
User Avatar

User Avatar

Wiki User

6y ago

The recommended method is to use a four wire (Y) to three wire (delta) transformer (sometimes called a "star-delta transformer").

This answer is:
User Avatar

User Avatar

Wiki User

6y ago

It is unclear what you want to do. It is very likely it cannot be done.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you connect 4 wire to 3 wire?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do you connect a 3 wire 120 outlet to a 4 wire 240 outlet?

You don't.


How do you wire a 4 lead 230v to a 3 lead 230v terminal?

connect the Red Yellow blue phases


How do you connect 3 wire to 2 wire 240volt's I'm trying to remove the washerdryer outlet and branch four 240v receptacles from the 240volt 3 wire outlet?

just leave the neutral wire as it is and connect the other two !!


How do you connect a three color wire to a 4 color wire?

Red is negavite some black


What is the firing order for a 1998 Pontiac trans sport?

The correct firing order is 5-2-3-6-4-1, the coil pack is number 1-2-3-4-5-6 so just connect the spark wire #5 to coil #1 wire #2 to coil #2 wire #3 to coil #3 wire #6 to coil #4 etc... it is NOT just 123456.


How do you connect a 240 v cooktop with 4 wires to a service panel with 3 wires?

The new cooktop has a 4 wire connection. Red & Black are hot. White is neutral, and green is ground. You existing panel is wired with 3 wires. Black & Red are hot and green is ground. There is no neutral wire. Connect the black to black, red to red, and then connect the white and ground together at the plug.


How do you wire a 3 wire 240 volt stove to a 240 volt 4 wire feed?

Change the cord/plug on the stove to a four wire cord/plug. When installing the new plug remove the grounding strip that connects the center lug in the stove wiring block to the frame of the stove. Connect the white wire from the new plug to the center lug. Connect the green wire from the plug to the stove frame.


Is it necessary to connect the ground wire to a 4-prong 240V outlet - I am switching a 3-outlet to a 4-prong outlet for my new dryer but the ground wire is cut off so I can't connect it?

Only if you wanted to fry your hair.for God sake(and yours)buy a new cord to hook up your dryer


How do you connect the wire from the alternator to the starter?

how do you connect the wire from the alternater to the starter?


How do I connect 6-3 wire to the breaker?

If you need to ask, you shouldn't be doing it.


How do you wire a 220 3 wire breaker to 4 wire dyer?

Buy a 3 wire cord for your dryer.


Can you connect a 3 wire fan into a 2 wire supply?

yes....the third wired can be connected to a metal housing of the 2 wire supply as a ground