answersLogoWhite

0


Best Answer

Schmitt trigger refers to an input hysteresis mechanism to improve the noise tolerance of a digital input, preventing glitch generation or false triggering on outputs.

A bistable multivibrator is a flipflop, a device capable of storing one bit.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

11y ago

schmitt trigger is also know as

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How does schmitt trigger differ from bistable multivibrator?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How schmitt trigger and square wave generator differ in their output waveform?

Yes,schmitt trigger has upper and lower threshold voltage for the reason of noise protection while square wave generator doesn't have these properties.


How does the plasma membrane at the trigger zone differ from that on the soma?

The plasma membrane has voltage gated channels whereas the soma does not.


What is the difference between the nand gate ic's 74ls00 and 74ls132?

The 74LS00 is a logic NAND gate with normal logic level inputs. This means that the inputs has a low range below 0.8V, unrecognised range and a high range above 2V. At any time a input signal crosses those levels, a change in state can be expected. Applicable to the LS family, they have a floating input that means it is uncertain the state of logic level if no input is connected. Therefore never assume that since the input is not connected that the circuit will assume a zero, it can be either zero or one. The 74LS132 is also a NAND gate logic function. But different to the Logic level input it uses what we call a Schmitt trigger input to improve noise immunity in a circuit. In simple terms; it's really nothing more than a comparator input. But the Schmitt trigger also have a hysteresis, which help to eliminate the affect what noise have on the circuit. On a more technical note Each circuit contains a 2-input Schmitt trigger followed by a Darlington level shifter and a phase splitter driving a TTL totem pole output. The totem pole is basically a push-pull output stage constructed with two p-n-p transistors and a diode on the output. The comparator function would mean that there is a particular threshold level on the input and if the input voltage pass the particular level, the output or intermediate state of the function will change state. In the case of multiple logic inputs the change of input state does not necessarily mean a change in output state and therefore I will refer to an intermediate area inside the function related to the input state. The hysteresis create a high and low trigger points. This cause the input to at least pass the high trigger point of about 1.6V before the intermediate state will change or drop below the 0.9V before the intermediate state change back again. Therefore the practical unit will not have one particular level to change state but these two fixed trigger points must be used. It sounds like it complicates matters but it really helps to handle input noise signals which makes the Schmitt trigger a handy device. Making it a good device for signal conditioning of logic signals in some applications. Also take note that the high and low hysteresis trigger points may vary with supply voltage. In fact I do not recommend it as standard practice to use a Schmitt trigger to evaluate analogue levels, some engineers may differ but I would rather refer to a real comparator circuit design where you have more control over precision, trigger points and reference levels. But may be considered for logic inputs from sensors or conditioning of logic signals Some circuits may also employ Schmitt trigger devices for oscillators and contact debouncing


What makes the blood groups differ from each other?

It is the presence or absence of particular antigens that determines the blood type. Antigens are substances which trigger the body's immune response.


How does the colt m911 differ from the m911a1 and the m911a2?

The Colt .45 pistol is an M1911, not an m911. The changes from an M1911 to an M1911A1 were: 1. the relief cuts behind the trigger 2. the short trigger 3. the arched main spring housing 4. the longer tang on the grip safety There is not m1911A2.


What actions can lead to ASMR?

Actions that trigger ASMR differ by person. Some triggers affect others while they have no affect on some.Some of these actions are:Nail bitingSoft whisperingHair play / brushing hairDrawing / colouringChewingTapping fingers


What is a sentence for the word differ?

The pair of them differ so much.Their opinions often differ.


Which preposition to use after differ?

differ


How do blue star differ from the red star?

they are differ by their color they are also differ in temperature


What is the root word for difference?

Differ.


How does mass differ from rate?

How does what differ from mass?


How do you use the word differs?

Use it as a verb. Shelly differs from Mary