How much is the amps to run a three phase motor?

Updated: 8/20/2019
User Avatar

Wiki User

10y ago

Best Answer

To find the amperage of a three phase motor, the following equation needs to be used. Amps = HP x 746/1.73 x Volts x % efficiency x power factor. once all of the values are added you can find the amperage of any Horsepower motor at any three phase voltage.

A standard motor's efficiency between 5 to 100 HP is .84 to .91.

A standard motor's power factor between 10 to 100 HP is .86 to .92.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How much is the amps to run a three phase motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How many amps does a 3 phase 22kw motor use?

22 kw motor how much takes ampares with load


Can you replace a three phase motor 3 Hp RPM 1420 with a single phase motor for a planer?

Probably not. The single phase three horse power motor will be much larger in physical size than its three phase counterpart, and will probably not fit.


How much is a three phase 20A motor in Australia?

Free


What size of circuit breaker do you use for 25amperes induction motor?

Read the specification plate on the motor to determine the amount of current that the motor uses, as well as the voltage and phase. Most likely, it will be a 3 phase motor, so you can't simply connect it to your house wiring, but without sufficient information, it is impossible to tell you all of the specifics. <<>> The code book rates the amperage of a three phase 40 HP motor by different voltages. at 200 volts - 120 amps, 230 volts - 104 amps, 460 volts - 52 amps and 575 volts - 52 amps. A breaker for a motor has to be sized to 250% of the motors full load amps. Also the wire size for a motor has to be 125% of the motor full load amps.


How much current will a 15 hp single phase 220 volt fan motor draw?

The wiring should allow for 115 amps.


Are all large motors three-phase?

Yes, most large motors are three phase. Usually single phase motors only go up to 10 HP. Larger than this and the wire size and contactors used to control the motors becomes extreme. For example a single phase 10 HP motor on 115 volts draws 100 amps. The same single phase motor on 230 volts draws 50 amps. The same 10 HP motor on three phase system draws the following amperage; 230 volts is a 28 amp draw, 460 volts is a 14 amp draw and 575 volts is a 11 amp draw. As you can see the higher the voltage becomes, the smaller the wire feeder size is needed and much smaller size contactor can be used to control the motor.


1TR equals how much amps in single phase?

To answer this question a three phase voltage must be given. I = W/E.


How much current will flow in neutral line for three phase supply 100amps?

If all three legs of the system are balanced then zero amps will flow all the way up to 100 amps if only one leg of the three phase system is used. The neutral in a wye three phase system carries only the unbalanced current. This is why in services for a three phase four wire system you are allowed to reduce the size of the neutral conductor.


How much a 3 ampere motor 220 v single phase is equal in kw?

As watts are made of volts times amps, the answer would be 0.660kw.


How much each circuit breaker amperes do you need for 3 phase 2200 watts motor?

To answer this question the voltage of the motor must be given. Watts is the product of amps x volts. Amps = Watts/Volts. Once this is found the motor breaker needs to be larger to allow for the inrush start current.


How different is the horsepower used by an air conditioner unit if it runs on either single phase or three phase ac?

There is no difference in horsepower. The manufacturer builds the air conditioner. Engineers calculate and tell the manufacturer how much power is going to be required to make it operate. Smaller units will probably use lower voltage with lower horsepower to operate efficiently. The bigger the unit will take higher horsepower to operate. There comes a point when single phase, low voltage use will not work due to the unavailability of high horsepower, low voltage motors. At this point three phase systems are used with higher voltages to operate the motors. Examples of a 10 HP motor at different voltages. Single phase - 115 volts 100 amps, 230 volts 50 amps. Three phase same HP - 200 volts 32.2, 230 volts 28, 460 volts 14 and 575 volts 11 amps. As you can see if the air conditioner needs a 10 HP motor at single phase 115 volts, a feeder supply of 100 amps would be needed. This compared to the same air conditioner using a three phase 575 volt system which draws 11 amps.


How much breaker load Amps required for 31 kw?

Impossible to say without more details. It depends entirely on the voltage of the supply and whether it's single-phase or three-phase.