Assuming you are working with 120v, you need #4 AWG copper conductors.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Is number 10 wire good for a 20 amp circuit that is 250 feet?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What number wire do you use to wire a washing machine outlet?

A 2C #14 will be suffice but it should be the only device on the circuit. This is known as a dedicated circuit.


What would be a good conductor for a closed circuit?

copper wire


What gauge wire do you need to run a 30 amp circuit 100 feet?

8 ga


What size wire for 100 feet 20 amp circuit to run pond fountain?

12 gauge underground wire or if you think you will ever add any devices to this circuit use 10 gauge.


What size wire do you need for 220 feet?

Cannot answer this question. Will need to know the voltage and amperage of the circuit. Also need to know the application i.e. is it a lighting circuit or a motor circuit?


What does it mean if an air bag light is blinking a number 42 code on a 1995 Lincoln Continental?

It means the Left Side Radiator Primary Crash Sensor Feed/Return Circuit Open. Broken wire, a disconnected wire, or something where the circuit path is not making a good connection.


How do you determine the number of branch circuit for lighting load?

An engineered set of blueprints will have all of the pertinent information about circuit loading and circuit numbers and panel balancing already calculated. If there is no wiring schedule on the print then you refer to the electrical code book and abide by the regulations that are set out for circuit loading and the amount of devices that can be connected to that circuit. Single family dwelling: multiply the number of square feet by 3. So a 2500 sq ft home times 3 = 7500 watts. Divide that number by 1500 for #14 wire circuits or 2000 for #12 wire circuits. 7500 divided by 1500 = 5 #14 wire circuits or if divided by 2000 + 3.75 or 4 #12 wire circuits. This would be for the lighting load and general use receptacles through out the home. I always lay my circuits out where a circuit only covers 500 sq ft of the dwelling.


Can one use 1 circuit of a 3 wire plus ground 2 circuit cable as a GFI circuit with the other as a lighting circuit?

A GFCI can not be used on a three wire branch circuit. It has to be on a single two wire circuit.


Where does the wire come from in an electrical circuit?

The wire comes from the installer or manufacturer of the circuit.


How do you change wire fuse for circuit breaker?

A circuit breaker does not have a wire fuse in it.


What number wire gauge for a single pole light switch?

In residential wiring applications the most used is 14 gauge wire for light switches as long as the circuit breaker or the fuse is 15A. If your lighting circuit is on a 20A fuse/circuit breaker then you need to use 12 gauge wire


Should you Run a 20amp circuit 150 feet with?

If this question is asking about voltage drop, to size a wire, a voltage is needed.