Q: Is the neutral wire on a 220v outlet the same as the ground?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Why not hook ground to neutral since they are hooked on same spot in breaker box why not in outlet box.?

The "hot" wire and the neutral wire both carry current (the same amount, in fact) when a load is connected to complete the circuit. The ground wire never carries current except when a fault-to-ground situation occurs. Yes, neutral and ground wires should both be at ground potential, but NO they should not be connected at the outlet.


When should you use an ungrounded outlet?

If the wiring system into which you are installing an outlet has no ground available, use an ungrounded outlet. In an ungrounded system, an outlet with a ground contact would allow the outlet user to mistakenly, and perhaps dangerously, assume that a ground was present. A suitable ground may be available as a ground wire accompanying the hot and neutral wires in the cable, or a ground may be available via conductive conduit and a metal outlet box. In any case, use a tester to confirm the integrity of the assumed ground. A voltage test from the hot wire to the ground should show the same voltage as between hot and neutral (the black and white wires respectively). If you are replacing an ungrounded outlet, you need not assume there is no ground present. You may find, in the box, ground wires that were not connected to the outlet. You may come across grounded outlets that have no ground wire attached because they rely on grounding via the mounting screws through the outlet ears to the metal box. This is a less reliable grounding method. It is better to buy a ground-wire "pigtail," fasten the wire directly to a hole in the metal box with the supplied screw, and attach the other end of the ground wire to the outlet via the outlet's ground screw.


Can you wire a 220v ballast with a 220 stinger and a neutral Or two 110 hot legs just the same?

A stinger is linemen terminology. Do you mean transformer instead of ballast. Please be more explicit as to what you are doing.


What happens to voltage during a short to ground?

Basically, the same as if you had a short to neutral, since the neutral and ground are tied to the same bus bar in the breaker panel. The breaker should trip, or the fuse should blow. Supply of voltage then stops.See the answer to the Related Question about GFCIs - shown below - for information about circuit protection when even a small current flows to ground.


Why is it that when you touch the neutral in a box that is not connect to the panel cause the test light to come when touching the power wire?

It shouldn't. The open end of a non connected neutral should have the same potential as the voltage feeding the circuit. The only time a voltage will show is when the return neutral is tested with a meter to the neutral bar or the ground return bar. It will then show what the supply voltage to the connected load is. Once this neutral is connected to the neutral bar there will be no voltage shown across the test meter between the neutral and the neutral bar or the ground bar.

Related questions

Why not hook ground to neutral since they are hooked on same spot in breaker box why not in outlet box.?

The "hot" wire and the neutral wire both carry current (the same amount, in fact) when a load is connected to complete the circuit. The ground wire never carries current except when a fault-to-ground situation occurs. Yes, neutral and ground wires should both be at ground potential, but NO they should not be connected at the outlet.


Does the electrical wall outlet half to be same hook up as hook up at box?

Yes, black is hot, white is neutral, and copper is ground.


Why would a wall outlet give a dim indication on a tester of hot-neutral reversed when everything appears to be wired correctly in the outlets?

A -dim- "hot/neutral reversed" indication means that there is -some- voltage, but less than 120V, on the neutral line, referenced to the safety ground. Ideally, the ground and neutral should be at the -same- potential, but a loose neutral connection "upstream" of this outlet will cause measurable voltage between ground and neutral. No need to swap any wires; just tighten neutral connections at all points (including outlets AND breaker panel) on the same circuit as this outlet. My guess is that whoever pulled the wire swapped the white/black wires from the point prior. Trace back the wire to the previous outlet and check the hook up. Try to swap your white/black line on the outlet and retest. If it checks ok, then the wire have been swapped from the previous point.


When should you use an ungrounded outlet?

If the wiring system into which you are installing an outlet has no ground available, use an ungrounded outlet. In an ungrounded system, an outlet with a ground contact would allow the outlet user to mistakenly, and perhaps dangerously, assume that a ground was present. A suitable ground may be available as a ground wire accompanying the hot and neutral wires in the cable, or a ground may be available via conductive conduit and a metal outlet box. In any case, use a tester to confirm the integrity of the assumed ground. A voltage test from the hot wire to the ground should show the same voltage as between hot and neutral (the black and white wires respectively). If you are replacing an ungrounded outlet, you need not assume there is no ground present. You may find, in the box, ground wires that were not connected to the outlet. You may come across grounded outlets that have no ground wire attached because they rely on grounding via the mounting screws through the outlet ears to the metal box. This is a less reliable grounding method. It is better to buy a ground-wire "pigtail," fasten the wire directly to a hole in the metal box with the supplied screw, and attach the other end of the ground wire to the outlet via the outlet's ground screw.


Some tools dont have ground wire?

Some tools don't have ground wires because the tool exterior is plastic or some other material that will not conduct electricity. The ground is not required unless the case is metal and can become electrified if the "hot" wire touches it.Sometimes the tool's plug is "polarized" by having one contact larger than the other so it can only be inserted into an outlet in one direction, insuring that the same wire is always the ground or neutral and the other is always the "hot" wire. That insures that the tool's ground is always connected to the outlet ground.Other times the plug has a third prong that is the ground or neutral prong and can only be inserted one way in the outlet to insure the ground of the tool is always connected to the ground of the outlet.


What is the reading ground to neutral?

Ideally ground and neutral should be at the same potential, but as there is current in the neutral wire and no current (normally) in the ground wire there can be a difference. I have personally measured over 25 VAC on the neutral relative to ground in some systems.


Wiring single toggle switch and outlet with two wire system?

Guessing you are replaceing an outlet? Black goes on the copper colored terminal and white on the same side that has the ground terminal. If you have checked and made sure that white is in fact the neutral you can run a jump wire from the side terminal to the ground. This will ground whatever you plug into the outlet as long as it has a 3 prong plug.


Why neutral to ground voltage is 0v sometime 120 v in same connection?

When the neutral is connected to the ground they are at the same potential which is zero volts. If the neutral gets disconnected from the ground then a potential of 120 volts will be measured from the open neutral to ground. This voltage is being measured from the neutral side of the load that is on the circuit. because they are actually the same cable at sub station, but split by the time they come to the board, long answer involved but that's the jist of it!


Where is the only place the neutral and ground wires can be on the same buss bar?

The main electric panel is where neutral is bonded to ground. There is usually a screw or strap that connects the two so the same type panel could be used as a subpanel and have the neutral and ground unbonded in subpanel.


How can you tell if the ground wire is approriately bonded to the neutral and the cabinet at the service box?

Ground wire can be appropriately bonded to the neutral and cabinet at the service box by connecting the neutral and ground wires from the feeder wires to the neutral bus bar and the ground terminal located on the same cabinet at the service box. White wire (neutral) must be connected to bus bar and bare wire must be connected to ground terminal in the same cabinet.


May you use earth wire as neutral wire?

1. SafetyWhen there are separate wires for neutral and ground it is much less likely that a problem in electrical wiring causes a dangerous situation which will cause electrical shock or fire.If the ground and neutral were the same conductor, the cutting only the neutral wire (for example by accident) would cause the grounded metal case of the equipment to be on mains potential just because there is only live connected to equipment and that voltage can go through the equipment to the cut neutral cable and from there to equipment case.When ground and neutral are separate, then cut neutral causes only the equipment to stop working and no dangerous situation. If ground gets cut by accident, there is no danger caused before some equipment gets damaged. So when there is separate wires for neutral and ground, a singe wire fault (cut or short circuit to other wire) on any wire going to outlet does not cause immediate danger to the user of the equipment:2. Minimizing the ground potential differences between outlet groundsIn an ideal separate grounding wire system there is no current flowing in ground wire network, so there is no voltage difference between grounds on different outlets. Unfortunately in real life systems there is always some current leaking to ground, but that current is very small (only probably milli amperes) compared to the current flowing on line and neutral wires (usually amperes).If the neutral and ground were shared on same wire, the current flowing on neutral wire would easily cause a large voltage difference (up to many volts) on different outlets grounds. The ground potential on any outlet will then depend on the load current, neutral wire resistance and the mains phase it is connected to.


On a 220 volt circuit where the white wire is common how many volts would the red wire be?

3 OR 4 . you only need 2 wires for 220, 1 phase is 120v between 2 of them its 220v . you also should have a ground for the third wire ,and the newer stuff requires a neutral or white wire for the 4th wire. hope i helped , D