answersLogoWhite

0


Best Answer

Metalic conduit is a metal tube that is used to shield wiring from damage, water contamination, contact with people. As opposed to plastic conduit.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is metallic conduit?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is another name for thin wall conduit?

There are many types of conduit used for the containment of electrical wires. PVC is a non-metallic option. If you need something that provides mechanical protection, EMT is a steel conduit with a thin wall. Need even more mechanical protection, you can use rigid conduit. It comes in steel or aluminum, and must be threaded together.


Another name for thinwall conduit is?

Another name for thin wall conduit is EMT and stands for Electrical Metallic Tubing. The term thin wall is used to differentiate between two conduit systems, thin wall and rigid conduit systems.


What is RSC in electrical?

In electrical terms it represents Rigid Steel Conduit. It is also known as Rigid Metal Conduit (RMC).This is not to be confused with Electrical Metallic Tubing (EMT) also known in the trade as thin wall conduit.


What is the Malayalam meaning of electrical metallic conduit?

Lohanirmmitha vidhyudh-pranaali (vaidhyuthakkuzhal) (ലോഹനിർമ്മിത വിദ്യുത്പ്രണാളി / വൈദ്യുതക്കുഴൽ)


What is the difference between armored cable and flexible metallic conduit?

Armored electrical cable contains insulated electrical service wires protected by a flexible steel covering. Metallic Conduit is a tube or pipe though which we lay electrical cable.(Most commonly lighting cables).


What is the function of connectors?

The connectors are those things that exotic


Can you use non metallic cable in half inch electrical metallic tubing conduit?

I don't see why not it will take up more space than regular building wire, so the capacity of the EMT will obviously be reduced


Is it necessary to ground at all metal junction boxes when using metal conduit or cable?

In a completely metallic conduit system it is not necessary to ground each junction box as long as the metallic system has the grounding capacity rating larger than that of the over current device protecting the circuit. The code book states what size conduits are rated at, for grounding amperages.


How can you test a rigid steel conduit system being used as an equipment ground conductor to ensure the conduit will be able to carry sufficient ground fault current?

No test is needed. The conduit sizes are laid out in the electrical code book. It states the current carrying capacity of each of the conduit sizes. These test were done by an underwriters test laboratory and approved to carry the stated current capacities. Where the trouble might arise is with the workmanship of the installation. An example, when threads in electrical conduit are involved wrenches must be used not just hand tight, The same thing goes with lock rings, hammer them on not just finger tight. The metallic conduit system needs to be tight to work. There are new code changes coming down the line that will state that a ground wire will have to be pulled along with the feeder wires in a metallic conduit system.


Why 2 different phase wire are not supposed to pass through same conduit?

According to the wording ,2 different phase wires "can" run through the same conduit. Not only can they, but if they are part of the same circuit they must. And in cases where conductors are paralleled, meaning more than one conductor per phase as is common in commercial and industrial installations, you put one conductor of each phase and a neutral, if one exists, and a ground in each conduit. Not doing so, meaning to put all of one phase in one conduit, causes a voltage to be induced into the conduit and a tremendous amount of heat builds up. Even when using pvc or other non-metallic conduit, somewhere along the way you have something metallic and have the same problem. To simplify, you must put all conductors associated with the same circuit in the same conduit.


What is The lightest duty and most widely used non-flexible metal conduit available for enclosing and protecting cabling and wiring is?

Electrical metallic tubing


Do you have to break the ground wire at a pull box and bond it to the box?

When you refer to a pull box you have to be talking about a conduit system. In a metallic system, no don't have to ground pull boxes. By the fact that it is a metallic system the conduit and associated boxes are already grounded by the connection to the distribution panel. In a PVC conduit system a ground wire has to be pulled so that the load device has a return ground wire to trip the breaker on a ground fault. Pull boxes in a PVC system don't have to be grounded just the last junction box at the load.