An ordinary transformer has two input/output terminals but a center tapped transformer has 2 input and 3 output terminals. One is taken from the center for a ground connection. This causes it to get 50% of the actual value.
And ordinary transformer contains 2 windings.
An autotransformer has one.
It means that the primary and/or secondary coil of the transformer literally has a connection half way through.
Transformers can have multiple taps to increase or decrease voltage and each tap either adds or subtracts windings to the transformer.
Variable transformer may also refer as auto transformer. We can vary the output voltage of the transformer. But in the ordinary transformers output voltage is already designed.
An isolation transformer is usually a ferromagnetic transformer. The question needs to be framed more usefully.
The difference between current transformer and potential transformer is that the secondary of a current transformer can not be open circuited while under service whereas that of the potential transformer an be open circuited without any damage to the transformer.
n '
The difference between the two transformers is the coil ratios between the primary and secondary windings. A transformer that increases voltage from primary to secondary has more secondary winding turns than primary winding turns and is called a step-up transformer. Conversely, a transformer with fewer secondary windings does just the opposite and is called a step-down transformer.
What is the difference between an ordinary transformer and resonant coupling energy transfer?
Variable transformer may also refer as auto transformer. We can vary the output voltage of the transformer. But in the ordinary transformers output voltage is already designed.
An ordinary transformer has two input/output terminals but a center tapped transformer has 2 input and 3 output terminals. One is taken from the center for a ground connection. This causes it to get 50% of the actual value. And ordinary transformer contains 2 windings. An autotransformer has one.
there is nothing like a balanced and unbalanced transformer.
EXTRA!!
The major difference between a solution and an ordinary mixture is that solution is homogeneous and an ordinary mixture is heterogeneous.
Both are same. This is an instrument transformer used for metering & protections.
The 3 kVA transformer will weigh double the 1.5 kVA transformer.
difference between ordinary prism and constant deviation prism
The difference between a tied grant and an ordinary grant is that a tied grant has conditions and the ordinary grants don't!
An isolation transformer is usually a ferromagnetic transformer. The question needs to be framed more usefully.
The difference between current transformer and potential transformer is that the secondary of a current transformer can not be open circuited while under service whereas that of the potential transformer an be open circuited without any damage to the transformer.