It protects the Pilot Light from being blown out
Yes,It depends if it is gas fired or electric.
16 x 20
form_title=Central Humidifier Installation form_header=7443 Please state the type of furnace you have.*= () Forced air gas () Forced air electric () Other What is the location of the furnace?*= () Attic () Garage () Closet () Roof () Other
The simple answer is yes it produces heat and is distributed to the rooms in your house; unless however, you are using electric baseboard heat which works on convection, or electric radiant heating panels.
Thermostat calls for heat. Induced draft fan motor starts. Vent pressure switch verifies pressure. Simultaneously gas valve opens and ignitor lights burner(ignition varies: hot surface ignitor, electronic spark ignitor, or standing pilot). Flame is sensed. High limit temperature switch is made. Blower fan runs. Thermostat calls for no heat. Gas valves close. Burners shut off. Induced draft fan shuts off. Blower fan put into fan delay(fan blower continues to run). Low limit temperature switch made. Fan blower stops.
It protects the Pilot Light from being blown out
It protects the Pilot Light from being blown out
The purpose of the vent on the furnace is to ventilate flue gases out side of the house.
The purpose of the vent on the furnace is to ventilate flue gases out side of the house.
The purpose of the vent on the furnace is to ventilate flue gases out side of the house.
The purpose of a drip leg in the gas piping is used as a device to capture dirt and debris from entering the furnace.
an electric furnace runs off of 208/230 Volts while a typical gas furnace runs off of 120 also a gas furnace will have a valve for the gas relay where the gas enters the furnace.
A gas furnace works by heating up the element inside the furnace. The gas comes into the furnace and is lit by a spark that comes from the pilot light. The fire heats up the element and air from the fan pushes the heat into the house.
You can find a schematic for a gas furnace on the website, Uncionradio.
The gas furnace pilot (flame is lit all the time) is sometimes referred to as a pilot light, but no matter what you call it, its purpose is to serve as a small ignition flame for the gas burner. And when this little flame fails to operate properly or go out, it's one of the most common reasons a gas furnace will fail to operate.
In a balanced draft boiler, you actually have both: forced draft (FD) fans supplying air to the furnace, and induced draft (ID) fans removing flue gas. Typically, the FD fans control airflow, while ID Fans control furnace pressure to slightly below atmospheric pressure. In general though, the choice between forced draft and induced draft is based on how "tight" the system is - if you have leaks, it is better to use ID, as FD will cause product loss.
You should not run gas from the furnace to any appliances.