Best Answer

Turn off the makeup water and electrical service to the boiler. Isolate any and all valves in the system. Thread the old tank off, thread tape and/ or thread sealant on male ends of new tank and thread it in. Bleed air from system as needed using makeup water. Dependent on the piping arangement, if the tank screws in the bottom of an air scoop, an air eliminator atop the scoop may be removed and then replaced after all air is purged. Note: in using makeup water valve/ bypass, do not go over 30# of pressure. Most residential boilers will have a safety relief valve that is set at 30# that will blow off at this pressure and make a mess. The makeup water pressure reducing valves are generaly set to maintain 12# of pressure. Most pressure tanks are precharged at the same 12# of pressure on the air side. Verify these pressures and that all air has been purged from the boiler and pumps, before refiring the boiler. lc

User Avatar

Wiki User

15y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

11y ago

The expansion tank is used for back pressure affecting ur water heater

This answer is:
User Avatar

User Avatar

Wiki User

10y ago

The purpose of a expansion tank for a hot water system is to protect hot water systems at home from excessive pressure as the tank is half filled with air.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you replace a expansion tank on a boiler system?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the function of a cold feed and expansion pipe?

Cold feed is cold water that supplies boiler water for heating system. Expansion tank relieves excess pressure buildup in heating system.The Cold feed should enter the supply line rather then the return as not to thermo shock a boiler and the expansion tank is to protect the system from excessive pressureAs water is heated it expands causing higher pressures the tank acts an asorber for this expansion


Why does gas boiler keep cutting out?

i am no expert - but the reason my boiler cuts out is a fall in the system pressure due to a leaking membrane in the expansion tank. I have to keep the pressure up by adding new water to the system. Bill


Why is Expansion tank on boiler is leaking at the air release valve?

It is possible that the expansion tank on a boiler could have too much water and not enough air, causing leaking. To fix this problem, the tank should be adjusted to the right levels of each.


How do you replace the coolant overflow tank?

how do I replace my 2005 fiesta expansion header tank


What is the function of the expansion tank in a hot water heating system?

To allow for the expansion of heated thot water


Why is there no pressure in your furnace for your forced hot water system?

=Possibly because a furnace is scorched air and a "boiler" is used for steam or hydronics==1-The loss of pressure could be a leak in the system==2- Incorrect setting on the automatic feeder==3- Improperly sized expansion tank=


How does expansion tank work?

the operation of a expansion tank?


What to do when you lose hot water pressure and only have cold water pressure?

This depends on whether the hot water comes from a combination boiler or from a hot water tank with a header tank feeding it. For a combination boiler the fault would probably be at the boiler, possibly from scale in the heat exchanger. For the system that uses the header tank and a hot water cylinder it could be that the float valve in the header tank is stuck an there for it is not refilling the tank or debris has entered the tank and is blocking the outlet.


Can expansion tank go bad on water heater?

Yes they can go bad but are relatively easy to replace.


Why would you be losing water from the expansion tank on your car?

i take it you are talking bout expansion tank on a/c this is evaporation and is common on all vehicles if you are talking bout expansion tank on radiator, you have either got to much coolant in radiator,(check level when cold) or you have an air lock in the cooling system and need the system bled to remove air


Is an expansion tank required for a tank less water heater?

No, an expansion tank is not required.


What air pressure is there in a pressure tank In a hot water heating system what should the pressure in the tank be?

A hot water heating systems water pressure should be 12-25 psi , the air in the expansion tank should be set around 10 psi but can only be accurately tested with no water pressure against it. Usually u can tell if the tank is bad when the relief valve on the boiler starts releasing water