When you wish to bring a second generator on-line in order to do maintenance on the first one. They would be connected in parallel, but not yet switched on together, until you are sure they are both in phase.
This is simply accomplished by connecting a light bulb between the Phase of one to the Neutral of the other. The bulb will wax and wane as the generators come in and out of phase. When the bulb is brightest, switch them together.
Because it is the only way you can connect them together to increase power supply. Generators cannot be connected in series because the power from one would necessarily have to pass through another overheating the stator coil and destroying the generator. In other words the power from the first generator would be converted to heat in the second OR it would turn the second generator into a motor drawing power from the system. Generators are equipped with reverse power relays to prevent this sort of action from occurring. By connecting generators into a parallel circuit from the "grid" it is able to generate power and push it out to the system.
yes it is just hook it up and go you will need to check your calcs as you will increase your amperage. while not often done I have done this before.
When two generators are to be run in parallel, one generator is first started and some load is given. Then second generator is brought in parallel with the running generator (subject few conditions, like voltage, frequency, phase angle). First generator which is running is known as running generator, the second generator which gets connected is known as incoming generator
Yes of course.. u just need some connecting wires to connect them in parallel
generators are machines that convert machanical energy to electrical energy and could be AC or DC. if in a DC generator has it field armature connection in both series and parallel its said to be compound dc generator.
3.5 x35 sqmm Aluminium Cable
To draw current from a generator, you need to connect a load to it.
yes it is just hook it up and go you will need to check your calcs as you will increase your amperage. while not often done I have done this before.
This will require a modification to your units to allow them to be "hooked" together. You will have to add another connection to your generator that connects to your generator output, one cable for each fase. Connect a slave cable from one unit to the other, and connect the communication cable so they can share the load. The generator will do the rest.
Yes it can if you connect it with an 120v generator. But it depends on how powerful the generator is.
Shunt means parallel only..................
You need to find a power source first. Such as, a windmill, etc.. Then you need to connect a generator to the power source. Then after the generator is working, you can connect wires from the generator, to the computer. After it is all connected, the computer(s) should be up and running perfectly! :) However, if you put a computer inside, there is no need to do all that work. A computer will work without a power source if it is inside.
If you connect two transistors parallel it will heat up and be damaged.
Remove all cables from the generator. Connect battery's + (plus) to the generator's A and then connect battery's - (minus) to the generator's F (field) for a second. Might give a small spark, but that doesn't hurt anybody.
In long shunt the shunt field winding is in parallel to both generator and series field. In short shunt the shunt field is in parallel to generator only.
To interface a parallel printer to a USB port, you need a USB Parallel Printer Adapter, Belkin makes a reliable one that I have used for years.
If your generator makes enough power to run your equipment then no they don't have to connect to your property unless you ask them to,
Connect it in Parallel.