Composition of dry atmospheric air
[1]
An air separation plant separates atmospheric air into its primary components, typically nitrogen and oxygen sometimes also argon and other rare inert gases. There are various technologies that are used for the separation process, the most common is via cryogenic distillation. This process was pioneered by Dr. Carl von Linde in the early 20th century and is still used today to produce high purity gases.[2] The cryogenic separation process [3] [4] [5] [6] requires a very tight integration of heat exchangers and separation columns to obtain a good efficiency and all the energy for refrigeration is provided by the compression of the air at the inlet of the unit. In addition to the cryogenic distillation method there are other methods such as Membrane, Pressure Swing Adsorption (PSA) and Vacuum Pressure Swing Adsorption (VPSA), which are typically used to separate a single component from ordinary air. Production of high purity oxygen, nitrogen, and argon as used for Semiconductor device fabrication requires cryogenic distillation, though. Similarly, the only viable sources of the rare gases neon, krypton, and xenon is the distillation of air using at least two distillation columns. Cryogenic ASU's are built to provide nitrogen and/or oxygen and often co-produce argon where liquid products (Liquid nitrogen "LIN", Liquid oxygen "LOX", and Liquid argon "LAR") can only be produced if sufficient refrigeration is provided for in the design.
The Cryogenic Process
To achieve the low distillation temperatures an Air Separation Unit (ASU) requires a refrigeration cycle that operates by means of the Joule–Thomson effect, and the cold equipment has to be kept within an insulated enclosure (commonly called a "cold box"). The cooling of the gases requires a large amount of energy to make this refrigeration cycle work and is delivered by an air compressor. Modern ASU's use Turboexpanders for cooling which is combined with the air compressor for improved efficiency. The process consists of the following main steps:
- Before compression the air is pre-filtered of dust.
- Air is compressed where the final delivery pressure is determined by recoveries and the fluid state (gas or liquid) of the products. Typical pressures range between 5 and 10 bar gauge. The air stream may also be compressed to different pressures to enhance the efficiency of the ASU. During compression water is condensed out in inter-stage coolers.
- The process air is generally passed through a molecular sieve bed, which removes any remaining water vapour, as well as carbon dioxide, which would freeze and plug the cryogenic equipment. Molecular sieves are often designed to remove any gaseous hydrocarbons from the air, since these can be a problem in the subsequent air distillation that could lead to explosions.[7] The molecular sieves bed must be regenerated. This is done by installing multiple units operating in alternating mode and using the dry co-produced waste gas to desorb the water.
- Process air is passed through an integrated heat exchanger (usually a plate fin heat exchanger) and cooled against product (and waste) cryogenic streams. Part of the air liquefies to form a liquid that is enriched in oxygen. The remaining gas is richer in nitrogen and is distilled to almost pure nitrogen (typically < 1ppm) in a high pressure (HP) distillation column. The condenser of this column requires refrigeration which is obtained from expanding the more oxygen rich stream further across a valve or through an Expander, (a reverse compressor).
- Alternatively the condenser may be cooled by interchanging heat with a reboiler in a low pressure (LP) distillation column (operating at 1.2-1.3 bar abs.) when the ASU is producing pure oxygen. To minimize the compression cost the combined condenser/reboiler of the HP/LP columns must operate with a temperature difference of only 1-2 degrees Kelvin, requiring plate fin brazed aluminium heat exchangers. Typical oxygen purities range in from 97.5% to 99.5% and influences the maximum recovery of oxygen. The refrigeration required for producing liquid products is obtained using the JT effect in an expander which feeds compressed air directly to the low pressure column. Hence, a certain part of the air is not to be separated and must leave the low pressure column as a waste stream from its upper section.
- Because the boiling point of argon (87.3 K at standard conditions) lies between that of oxygen (90.2 K) and nitrogen (77.4 K), argon builds up in the lower secion of the low pressure column. When argon is produced, a vapor side draw is taken from the low pressure column where the argon concentration is highest. It is sent to another column rectifying the argon to the desired purity from which liquid is returned to the same location in the LP column. Use of modern structured packings which have very low pressure drops enable argon purities of less than 1 ppm. Though argon is present in less to 1% of the incoming, the air argon column requires a significant amount of energy due to the high reflux ratio required (about 30) in the argon column. Cooling of the argon column can be supplied from cold expanded rich liquid or by liquid nitrogen.
- Finally the products produced in gas form are warmed against the incoming air to ambient temperatures. This requires a carefully crafted heat integration that must allow for robustness against disturbances (due to switch over of the molecular sieve beds[8]). It may also require additional external refrigeration during start-up. The air gases are sometimes supplied by pipeline to large industrial users adjacent to or nearby to the production plant. Unless a viable pipeline system exists, long distance transportation of products is usually done as a liquid product for large quantities or as dewar flasks or gas cylinders for small quantities.
See also
Industrial gas companies
References
- ^ NASA Earth Fact Sheet, (updated November 2007)
- ^ Linde Group, Corporate History
- ^ Latimer, Chemical Engineering Progress (1967) Vol. 63 (2) pp. 35-59
- ^ R. Thorogood, "Developments in air separation", Gas Separation & Purification (1991) Vol. 5 June pp. 83-94 [1]
- ^ R. Agrawal, "Synthesis of Distillation Column Configurations for a Multicomponent Separation", Industrial Engineering Chemistry Research (1996) Vol. 35 pp. 1059-1071 [2]
- ^ W.F. Castle, "Air Separation and liquefaction: recent developments and prospects for the beginning of the new millenium", International Journal of Refrigeration (2002) Vol. 25, pp. 158-172 [3]
- ^ Particulate matter from forest fires caused an explosion in the air separation unit of a Gas to Liquid plant, see [4]
- ^ Computer Chemical Engineering (2006) Vol. 30 pp. 1436-1446