bathtub curve

(′bath′təb ′kərv)

(industrial engineering) An equipment failure-rate curve with an initial sharply declining failure rate, followed by a prolonged constant-average failure rate, after which the failure rate again increases sharply.


 
 
Wikipedia: bathtub curve
The "bathtub" curve hazard function
Enlarge
The "bathtub" curve hazard function
A bathtub, whence the term is derived
Enlarge
A bathtub, whence the term is derived

The bathtub curve is widely used in reliability engineering, although the general concept is also applicable to humans. It describes a particular form of the hazard function which comprises three parts:

  • The first part is a decreasing failure rate, known as early failures or infant mortality.
  • The second part is a constant failure rate, known as random failures.
  • The third part is an increasing failure rate, known as wear-out failures.

The name is derived from the cross-sectional shape of the eponymous device.

The bathtub curve is generated by mapping the rate of early "infant mortality" failures when first introduced, the rate of random failures with constant failure rate during its "useful life", and finally the rate of "wear out" failures as the product exceeds its design lifetime.

In less technical terms, in the early life of a product adhering to the bathtub curve, the failure rate is high but quickly decreasing as defective products are identified and discarded, and early sources of potential failure such as handling and installation error are surmounted. In the mid-life of a product - generally, once it reaches consumers - the failure rate is low and constant. In the late life of the product, the failure rate increases, as age and wear take its toll on the product. Many consumer products strongly reflect the bathtub curve, such as computer processors.

The bathtub curve is often modeled by a piecewise set of three hazard functions,

y(t) = \begin{cases} c_0-c_1t+\lambda, & 0\le t \le c_0/c_1 \\ \lambda, & c_0/c_1 < t \le t_0 \\c_2(t-t_0)+\lambda, & t_0 < t \end{cases} \!

While the bathtub curve is useful, not every product or system follows a bathtub curve hazard function. [1]

The term "Military Specification" is often used to describe systems in which the infant mortality section of the bathtub curve has been burned out or removed. this is done mailinly for life critical or system critical applications as it severly reduce the possibility of the system failing early in its life. Manufacturers will do this at some cost generally by means similar to accelerated stress testing.

External Links

References


 
 

Join the WikiAnswers Q&A community. Post a question or answer questions about "bathtub curve" at WikiAnswers.

 

Copyrights:

Sci-Tech Dictionary. McGraw-Hill Dictionary of Scientific and Technical Terms. Copyright © 2003, 1994, 1989, 1984, 1978, 1976, 1974 by McGraw-Hill Companies, Inc. All rights reserved.  Read more
Wikipedia. This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article "Bathtub curve" Read more

Search for answers directly from your browser with the FREE Answers.com Toolbar!  
Click here to download now. 

Get Answers your way! Check out all our free tools and products.

On this page:   E-mail   print Print  Link  

 

Keep Reading

Mentioned In: