Dictionary: go·ni·om·e·ter   ('nē-ŏm'ĭ-tər) pronunciation
n.
  1. An optical instrument for measuring crystal angles, as between crystal faces.
  2. A radio receiver and directional antenna used as a system to determine the angular direction of incoming radio signals.

[Greek gōniā, angle + -METER.]

goniometric go'ni·o·met'ric (-nē-ə-mĕt'rĭk) or go'ni·o·met'ri·cal adj.
goniometry go'ni·om'e·try n.

Search unanswered questions...
Enter a question here...
Search: All sources Community Q&A Reference topics
Food and Fitness: goniometer
Top

A device containing a 180 degree protractor for measuring the angle of a joint; it is used in tests of flexibility. Some goniometers can only measure the angle of a static joint, but an electrogoniometer can record continuously the changes in the angle of a joint during movements.

A device containing a 180° protractor for measuring static flexibility. The centre of the goniometer is positioned at the joint axis and the arms of the goniometer are aligned with the longitudinal axis of the body segments to measure the angle present at stationary joint. Compare electrogoniometer.

Veterinary Dictionary: goniometer
Top

An instrument for measuring angles; the instrument used in goniometry.

Obscure Words: goniometer
Top


an instrument for measuring angles; direction finder
Wikipedia: Goniometer
Top
Manual (1), and Mitscherlich's optical (2) goniometers for use in crystallography, ~1900

A goniometer is an instrument that either measures angle or allows an object to be rotated to a precise angular position. The term goniometry is derived from two Greek words, gonia, meaning angle and metron, meaning measure.

Contents

Types

There are many types of goniometers, each specialised for its particular application.

Audio

An audio goniometer is used to see the amount of stereo in a signal.

Communications

Goniometers are used for direction finding in signals intelligence applications for military and civil purposes[1], e.g. interception of satellite and naval communications as performed on the French warship Dupuy de Lôme uses multiple goniometers.

Crystallography

A goniometer for crystallography

In crystallography, goniometers are used for measuring angles between crystal faces. They are also used in X-ray diffraction to rotate the samples. The groundbreaking investigations of physicist Max von Laue and cohorts into the atomic structure of crystals in 1912 involved a goniometer.

Light Measurement

Goniophotometers measure the spatial distribution of light visible to the human eye at a specific angular position.

Physical therapy

In occupational therapy and physical therapy, a goniometer is an instrument which measures an axis and range of motion. If a patient or client is suffering from decreased range of motion in a joint (e.g. a knee or elbow), the therapist can use a goniometer to assess what the range of motion is prior to intervention, and then make sure the intervention is working by using the goniometer in subsequent interventions.

Surface science

Surface scientists use contact angle goniometers to measure surface energy and surface tension.

In surface science, an instrument generally called a contact angle goniometer is used to measure the static contact angle, advancing & receding contact angles, and surface tension. The first contact angle goniometer was designed by Dr. William Zisman of the United States Naval Research Laboratory in Washington, DC and manufactured by ramé-hart (now ramé-hart instrument company), New Jersey, USA. The original manual contact angle goniometer used an eyepiece with microscope. The current generation of contact angle instruments uses cameras and software to capture and analyze the drop shape and are better suited for dynamic and advanced studies. A Gonioreflectometer is used to measure the reflectivity of a surface at a variety of angles.


Static Contact Angle

A liquid droplet rests on a solid surface and is surrounded by gas. The contact angle, θC, is the angle formed by a liquid at the three phase boundary where the liquid, gas, and solid intersect.
The contact angle, θ, is the angle formed by a liquid at the three phase boundary where the liquid, gas, and solid intersect. The contact angle depends on the interfacial tensions between the gas & liquid, liquid & solid, and gas & solid. Young’s Relation expresses the contact angle analytically[2].
\gamma_{SG}\ =\gamma_{SL}+\gamma_{LG}\cos{\theta}
where
\gamma_{SG}\ = Interfacial tension between the solid and gas
\gamma_{SL}\ = Interfacial tension between the solid and liquid
\gamma_{LG}\ = Interfacial tension between the liquid and gas
Contact angle goniometers measure a droplet’s contact angle by assuming the droplet fits the geometry of a sphere, ellipsoid, or the Young-Laplace equation.
Another perspective that describes contact angles uses cohesion VS adhesion. Cohesion is the force between the liquid molecules which hold the liquid together. Adhesion is the force between the liquid molecules and the solid molecules. The contact angle is a quantitative measure that tells the user the ratio of cohesion VS adhesion. If the contact angle is near zero, meaning the liquid droplet spreads completely on the solid surface, adhesive forces are dominating. If the contact angle is very high, meaning the liquid droplet beads up on the solid surface as water does on a freshly waxed car, cohesive forces are dominating.

Advancing and Receding Contact Angles

While static contact angles give static information about the interfacial tensions between the solid, liquid, and gas, advancing and receding contact angles give some information about the dynamic interaction of the liquid, solid, and gas. An advancing contact angle is determined by pushing a droplet out of a pipette onto a solid. When the liquid initially meets the solid it will form some contact angle. As the pipette injects more liquid through the pipette, the droplet will increase in volume, the contact angle will increase, but its three phase boundary will remain stationary until it suddenly jumps outward. The contact angle the droplet had immediately before jumping outward is termed the advancing contact angle. The receding contact angle is now measured by sucking the liquid back out of the droplet. The droplet will decrease in volume, the contact angle will decrease, but its three phase boundary will remain stationary until it suddenly jumps inward. The contact angle the droplet had immediately before jumping inward is termed the receding contact angle. The difference between advancing and receding contact angles is termed contact angle hysteresis which can be used to characterize surface heterogeneity, roughness, and mobility[3]. Surfaces that are not homogeneous will have domains which impede motion of the contact line.

Surface Tension

Surface tension exists because the molecules inside a liquid experience roughly equal cohesive forces in all directions, but molecules at the surface experience larger attractive forces toward the liquid than toward gas
The Pendant Drop Method can determine the surface tension or interfacial tension of a fluid
Contact angle goniometers can also determine the surface tension for any liquid in gas or the interfacial tension between any two liquids. If the difference in densities between the two fluids is known, the surface tension or interfacial tension can be calculated by using the pendant drop method. Surface tension quantifies the cohesive force present at the surface of a droplet. Contact angle goniometers measure surface tension by examining a drop hanging from a syringe tip in air. The balance of forces acting on the drop include the surface tension. The surface tension can be calculated using the below equation

\gamma=\frac{\Delta\rho g R}{\beta}

where:

  • \scriptstyle \gamma is the liquid-air surface tension (J/m² or N/m)
  • β is the shape factor
  • Δρ is the difference in density between fluids at the interface (kg/m3)
  • g is acceleration due to gravity (m/s²)
  • R is the radius of the drop curvature at the drop’s apex (m)


3 dimensionless first order equations can define the shape factor
  • dx/ds = cosθ
  • dz/ds = sinφ
  • dφ/ds = 2 + βz – sinφ/x
Iterative approximations can solve for β.

Positioning

A miniature electro-mechanical goniometer stage. This type of stage is used primarily in the field of lasers and optics.

A positioning goniometer or goniometric stage is a device used to rotate an object precisely about a fixed axis in space. It is similar to a linear stage, however, rather than moving linearly with respect to its base, the stage platform rotates partially about a fixed axis above the mounting surface of the platform. Positioning goniometers typically use a worm drive with a partial worm wheel fixed to the underside of the stage platform meshing with a worm in the base. The worm may be rotated manually or by a motor as in automated positioning systems.

Knife and blade cutting edge angle measurement

The included cutting angles of all kinds of sharp edge blades is measured using a laser reflecting goniometer. Developed by CATRA in the UK, a range of devices can accurately determine the cutting edge profile including a rounding of the tip to 1/2°. The included angle of a blade is important in controlling its cutting ability and edge strength, i.e a low angle makes the edge thin and optimized for cutting while a large angle makes it thick, which cuts poorly, but is very strong.

See also

References

  1. ^ Jacqueline Boucher (2007-05-03). "Radio receiver workload accelerates". http://www.army.mil/-news/2007/05/03/2975-radio-receiver-workload-accelerates/. Retrieved 2007-09-21. 
  2. ^ Young, T. (1805). "An Essay on the Cohesion of Fluids". Phil. Trans. R. Soc. Lond. 95: 65–87. doi:10.1098/rstl.1805.0005. 
  3. ^ KSV Instruments. Operation Manual for Contact Angle Goniometer. 

External links


Translations: Goniometer
Top

Dansk (Danish)
n. - goniometer, vinkelmåler

Nederlands (Dutch)
hoekmeter

Français (French)
n. - goniomètre

Deutsch (German)
n. - Winkelmesser

Ελληνική (Greek)
n. - γωνιόμετρο

Italiano (Italian)
goniometro

Português (Portuguese)
n. - goniômetro (m) (Eletr.)

Русский (Russian)
гониометр (угломерный прибор)

Español (Spanish)
n. - goniómetro, grafómetro

Svenska (Swedish)
n. - goniometer (vinkelmätare)

中文(简体)(Chinese (Simplified))
角度计, 测角器

中文(繁體)(Chinese (Traditional))
n. - 角度計, 測角器

한국어 (Korean)
n. - 각도계, 무선 방위계

日本語 (Japanese)
n. - 角度計

العربيه (Arabic)
‏(الاسم) مثقله : اداة لقياس, الزوايا‏

עברית (Hebrew)
n. - ‮מד-זווית, גוניומטר‬


 
 
Learn More
goniometric
radiogoniometer (electronics)
electrogoniometer

What is a goniometer? Read answer...

Help us answer these
What is electronic goniometer?
How do you use a goniometer in physical exam?
Is limb trejectory can be measured by goniometer?

Post a question - any question - to the WikiAnswers community:

 

Copyrights:

Dictionary. The American Heritage® Dictionary of the English Language, Fourth Edition Copyright © 2007, 2000 by Houghton Mifflin Company. Updated in 2009. Published by Houghton Mifflin Company. All rights reserved.  Read more
Food and Fitness. Food and Fitness: A Dictionary of Diet and Exercise. Copyright © 1997, 2003 by Oxford University Press. All rights reserved.  Read more
Sports Science and Medicine. The Oxford Dictionary of Sports Science & Medicine. Copyright © Michael Kent 1998, 2006, 2007. All rights reserved.  Read more
Veterinary Dictionary. Saunders Comprehensive Veterinary Dictionary 3rd Edition. Copyright © 2007 by D.C. Blood, V.P. Studdert and C.C. Gay, Elsevier. All rights reserved.  Read more
Obscure Words. © 2008 by Michael A. Fischer http://home.comcast.net/~wwftd Read more
Wikipedia. This article is licensed under the Creative Commons Attribution/Share-Alike License. It uses material from the Wikipedia article "Goniometer" Read more
Translations. Copyright © 2007, WizCom Technologies Ltd. All rights reserved.  Read more