Best Answer

Between .5 meg ohms to 2 meg ohms is a safe range for your house wiring insulation. Infinity is the ultimate.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Between what values should the safe reading of insulation resistance of a domestic house?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the maximum insulation resistance reading on a 800A busbar?

infinite


What test would identify a short circuit in a lighting circuit?

earth continuity insulation resistance polarity


Between what values should the safe reading of a 10 sq protective conductor of a domestic house be?

Between what values should the safe reading of a 10 sq protective conductor of a domestic house be?


What is dielectric absorption ratio?

This is a test usually used when performing a insulation resistance on a transformer. This test (result) can be optained by deviding the 30 sec reading into the 60 sec reading. This test recognizes the fact that "good" insulation will show a gradually increasing IR after the test voltage is applied.


What is meggers?

A megger is an electrical instrument that is used to measure the resistance of insulation by applying a DC voltage to the conductor. One lead is connected to the conductor and the other lead is connected to ground. Safe insulation reading to ground should be above 2,000,000 ohms or 2 megs.


What should be the insulation resistance in a electrical circuit?

As we know thath insulators are the materials which are mainly use to insulate any conducting body from the LIVE supply whether 3Ph or single phase, so the reristence of such an insulator should be infinity as it should be provide maximum resistance to the flow of current through it.


Why must do the insulation testing in circuit?

Insulation resistance testing involves applying a voltage across a dielectric, and measuring the resulting current and resistance. However, in order to get a proper reading, any electrical charge still within the system needs to be taken out, so as not to mess with the readings.


What is dielectric absorption rate?

Dielectric absorption rate or ratio is a testing parameter used to determine the opposition to current flow through an insulating material sometimes expressed as insulation resistance in ohms or megohms. Testing the integrity of insulation involves measuring its resistance to current flow across or through it at specific voltage levels. A high level of resistance indicates that very little current is escaping through the insulation. Conversely, a low level of resistance indicates a significant amount of current may be leaking through and along the insulation. Similar to capacitive current, absorption current starts out relatively high and then decreases over time. As the voltage increases, the absorption level in the insulation decreases. This gradual change reflects the potential energy stored in and around the insulation. The dielectric absorption rate or ratio is the comparison of the leakage current or insulation resistance over a set time interval. The end reading divided by the initial reading yields a number which if less than 1.00 generally indicates faulty insulation. Another test similar to the dielectric absorption test is the polarization index ratio. This test is performed in much the same manner except with a longer time interval.


What is the maximum insulation resistance reading on a ring main circuit?

Insulation resistance is measuring the integrity of a conductor's insulation, therefore there is no upper limit as such. Most insulation resistance testers will indicate either >200 (Megohms) or >999 (Megohms) if they reach their maximum measuring capability. What you should be concerned with is the MINIMUM reading permissible: the current edition of BS7671 (17th Edition IEE Wiring Regs) specifies a minimum value of 1 Megohm (1 million ohms) as 'acceptable', but anything lower than 2 Megohms will require further investigation. Some electrical contractors would investigate much higher readings, especially if comparing readings with other circuits that have been tested at the same time, and which have given very high readings.


What is passable megger reading for 400 amp service?

A megger is a testing device used to test the insulation integrity of conductors. It measures resistance. It is terribly imprecise so actual readings are difficult to determine. Any passable reading will approach infinity (meaning almost infinite resistance) since there should be no flow of electricity from one conductor to another or from one conductor to ground.


Why it is essential for voltmeters to have a very high resistance?

if the resistance of the meter is low that will act as a parallel load effecting the reading. If the meter can be made with infinite resistance then the meter will not effects the actual reading.


Formula to calculate min insulation resistance?

insulation resistance = (2 * operating voltage +1000V) at operating temperature if you define what you mean by minimum insulation resistance maybe i could help 132,000V on the towers is usually happy with 6' of air some insulation is far better than air dry air 500v/mill thermoplastics 6000v/mill your power drill has 1/8" - 1/4" of plastic on the cord and perhaps .001" on the wire in the coils the cord gets rougher handling anything practical insulation resistance (2 * operating voltage +1000V) witch means a 1500Vdc megger is ok for 120V appliances should be safe to handle if its more than 10megohms the 1500V will bridge any pinholes or airgaps NEVER use a vom the 9v battery wont find a pinhole or an air gap ceramic on heaters and toasters has a way of letting metals diffuse in it lowering the resistance over time also it usually lowers with temperature so the resistance reading will be a lot lower while its hot