You would need to put an amp-meter on the circuit to see what the current draw is like. ====== If the compressor is shorted to ground you cannot check the amp draw because it will constantly kill the circuit breaker. A better way to go would be to check the continuity of the compressor to ground and each winding.

User Avatar

Wiki User

17y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How can you test a compressor to see if it has shorted?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the bar-over test of a compressor?

see API 618 description


What is the purpose of a growler test?

I think it's a test for a shorted armature.


Why my ac fuse keeps blowing in my 04 Oldsmobile alero?

More than likely the a/c compressor is bad. The compressor clutch could be shorted also.


Analysing a circuit with a shorted component?

Analysing a circuit with a shorted component need specialised electrical test equipment.


How can you test the air suspension compressor to see if it is working on a town car?

turn switch off and on


What causes the fuse in your 1999 Pontiac grand prix controls the air conditioning to get hot and blow out?

Defective/Shorted Compressor Defective/shorted blower motor Defective/shorted cooling fan Disconnect each of the above one at a time to determine which area is the problem


What equipment is used to test if armature is shorted?

An ohm meter.


How do i get the speaker on my 2002 Echo to start working?

Speakers generally work when they are connected to the radio and not shorted out. You can test the terminals with a multimeter to see if its getting power.


How can a compressor be tested for efficiency?

There are a few ways to test a hermetic compressor for efficiency.Compressor Vacuum TestClosed-Loop Compressor Running Bench TestClosed-Loop Compressor Running Field TestCompressor Running Test in the System


How can a hermetic compressor be tested for efficiency?

There are a few ways to test a hermetic compressor for efficiency.Compressor Vacuum TestClosed-Loop Compressor Running Bench TestClosed-Loop Compressor Running Field TestCompressor Running Test in the System


Why does the fuse keep blowing when the compressor starts on a dual compressor package unit?

MOST LIKELY A COMPRESSOR SHORTED TO GROUND IF 3 PHASE. COMPRESSOR START PARTS OR SHORTED COMPRESSOR- SINGLE PHASE. COULD ALSO BE CONDENSER FAN MOTOR OR CAPACITOR ASSUMING IT STARTS WITH THE PRIMARY COMPRESSOR. WITH POWER OFF, CHECK WITH OHMMETER EACH COMPRESSOR LEAD TILL YOU FIND SHORT (LOW RESISTANCE READING). IF THREE PHASE, IT IS POSSIBLE TO REVERSE MOTOR DIRECTION IN AN ATTEMPT TO FREE UP A FROZEN COMPRESSOR (RECIP ONLY, NOT FOR SCROLL IN THAT THEY ARE ROTATION SPECIFIC). ONCE YOU GET IT GOING OR HAVE COMPRESSOR REPLACED, FIND OUT WHAT CAUSED FAILURE AND FIX IT. IT WILL JUST HAPPEN AGAIN IF YOU DON'T. THEY DON'T JUST WEAR OUT IF MAINTAINED PROPERLY. lc


How do you test a compressor?

To test a compressor if locked up read the tag on compressor for locked rotor amps, then bypass safety therm-o-switch found under protective black cover on compressor, and with a clamp-on amp meter momentarily run compressor to check amperage.