For USA, Canada and countries running a 60 Hz supply service.

Your old range didn't require a neutral but your new one does... So, if you are upgrading your range, you must upgrade the wiring to it.

Such an old-fashioned range circuit really needs to be upgraded all the way from the breaker box: a pair of new breakers to a common-tie two pole breaker, a new length of correctly-sized cable (with red and black hots, white neutral and bare ground) and a new 4-wire outlet.

If you're not sure about the latest wiring codes or regulations that apply to where your home is, it is best to ask a professional Licensed Electrician for advice or to do the job for you.

<><><>

Nooo... it's the Ground the old range may not have been connected-to. There's always a neutral line, but for a very long time you weren't required to ground ranges in site-built dwellings. (You had to ground the range in a mobile home. I have no idea why there was a disparity.) [Update: It was because they more more likely to have damp or wet walls and floors - a real health hazard.]

Basically, you need either new range circuit wiring and 4-prong outlet (the preferred method -- installing a 4-prong outlet will bring your house up to code in that one part of its electrical system) or a new 3-prong cord.

If you decide to keep the old range circuit wiring and 3-prong outlet you must change the cord on the new appliance from 4-prong to 3-prong. Then you must connect the frame of the new range either to the existing separate ground wire, if there is one - it is either green-sheathed or bare copper - or, if there is no existing separate ground wire, you must ensure that the frame of the new range is connected to the neutral line by using an internal frame-to-neutral tie strap.

BUT first of all - before you do that - you must consult your local Electrical Safety Inspection Authority - or a local licensed electrician - to find out if it is still legal to use a 3-prong cord with no separate grounding conductor where you live.

If you needed to ask this question here the best advice anyone should give you is to call in an experienced electrician to ensure this work is done correctly either way. It's not very expensive and it will help ensure that your own life - and that of any members of your family, visitors or future home owners - will stay safe.

<><><>

It may be worth noting that, in some very old homes, a 220-240 volt range circuit may have no neutral wire, just two "hot" wires. They might even have just a big 2-prong plug and socket and a completely separate ground wire directly connected to the frame of the range.

A lot of those range circuits were updated - many years ago - to the many 3-prong plugs and sockets you still see today, which have now been superceded by the present 4-prong plug and socket outlet which is specified in the NEC. (The National Electrical Code).

The two 120 volt hots might be colored either "red and black", "black and black", or "red and red". The ground wire might be just bare copper or be covered with green insulation. That kind of circuit cannot safely supply a modern range which needs 240 volts for the heating elements and 120 volts for the clock/programmer and a 120 volt socket if there is one on it.

Cable sets for dryers and ranges - or for that matter any three wire cable sets - all have bare copper ground wires in them. For proper fault protection, this bare copper ground wire is sized in relationship to the current-carrying wires.

<><><>

(LIFE SAFETY WARNING! [disclaimer]

Electricity is dangerous!

You can be injured or killed!

Improper installations can cause fire, injury and death!

Should you be doing this yourself?)

TURN THE POWER OFF!

CALL AN ELECTRICIAN!

This is one of the most commonly asked questions in FAQ forums about electricity and wiring.

It must be understood that new appliances will be designed to meet the newest standards.

It is not reasonable to expect someone to rewire their home because they need a new dryer or range! [stove]

According to the NEC [National Electrical Code], in many places in the US it is now required to isolate the neutral conductor from the appliance frame or chassis.

It used to be allowable to use the neutral as a means of grounding by incorporating a link between the neutral and the chassis.

The problem with this is that, should the neutral become "open" at some point, the chassis or frame then becomes energized!

The answer to this safety issue was to require a separate grounding conductor in the cable feeding the appliance.

The old 3-prong method can still be used in certain localities (states/towns) so, unless you are already qualified yourself (in which case you would not be asking this question here!) you must consult your local Electrical Safety Inspection Authority - or a local licensed electrician - to find out if it is still legal to use a 3-prong cord with no separate grounding conductor where you live.

<><><>

For more information see the answers to the Related Questions shown below.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

12y ago

don't use the grounding screw,just hook up the two outside and the one in the middle.the grounding screw is usually above the terminal block attached to the frame

<<>>

Change the cord on the range to a four wire cord.

Cord set three wire to a four wire.

Instructions should come with the new cord. Open up the electrical access panel on the back of the range. You will see a terminal block with three wires going into it from the plug cord assembly. A red and black and white are now connected to the terminal strip. Look at the position and colours of the existing 3 prong cord and how it is connected. Make a diagram. Coloured wires on the outside terminals white in the center. From the center wire terminal you will see a jumper strap that goes to the frame of the range. When installing the four prong plug this jumper is removed completely. The kit should have with it a grounding lug, that connects to where the removed grounding strip was attached to the frame of the dryer. This is the attachment point for the fourth green ground wire from the new dryer cord assembly.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

You need to understand what is in play here. A standard 3-prong 110 VAC outlet has a ground (bare wire or green), neutral or common (white) and hot (black). The operating voltage is measured between the black and white wires. A residential 4-prong outlet would typically be for a 220 VAC outlet for a dryer or stove. In this case you still have a ground and a common, but now you have two hots (typically red and black). There is 220 volts across red and black and 110 volts between white and black and white and red.

To rewire you need to go back to the electric panel and run a new 3-wire cable (the ground wire is not counted) of the right size for the required current and you need a two pole breaker which will have connections for red and black wires. The white goes to the common bus in the panel and ground goes to the ground bus.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

Prior to the 2002 revision of the NEC (National Electric Code) the metal frames of electric ranges could be grounded by bonding (connecting) the frame to the neutral (white) or grounded conductor. Starting with the 2002 Code a separate grounding conductor had to be run from the panel to the range outlet which changed from a three-pole to a four-pole receptacle. The grounding pole is the round hole in the receptacle. All new range circuits are required to be four-pole circuits. You can legally convert your range to a three wire range if and only if there is a three-pole range receptacle circuit already installed. To convert to a three-wire whip simply bond he body of the stove to the center post with the white neutral or grounded conductor attached to it. Use a short length of bare copper wire or green insulated wire as a bonding conductor. Click the link to a web page that actually shows you the connections of both a 3-pole and a 4-pole circuit. In the 5-pole circuit the bonding conductor that I spoke of is actually the brass strip connecting the frame to the neutral post.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you hook up a 4 prong outlet to an old range that requires a 3 prong?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

If your outlet is a 3 prong outlet can you hook up a 3 prong plug from your old stove to a new stove which has a 4 prong plug?

No you can not you will need to replace the plug with a 4 prong the same as the style of your oven and change your breaker to the correct Amp for your style of 4 prong plug


How do you hook up 4 prong cord to 3 prong dryer?

To adapt a three prong range cord?&aelig;to a four prong outlet you need to remove the screws from the back plate to open the electric access panel. Then, pull out the copper grounding strip attached to the middle terminal. Next, remove the green ground screw from under the terminal block and attach it to the four prong outlet.?&aelig;


Is it necessary to connect the ground wire to a 4-prong 240V outlet - I am switching a 3-outlet to a 4-prong outlet for my new dryer but the ground wire is cut off so I can't connect it?

Only if you wanted to fry your hair.for God sake(and yours)buy a new cord to hook up your dryer


Where do the red and black wires hook into on a 50a 4 prong surface mount power outlet for a stove?

A 14-50R range receptacle pin identification are as follows. U shaped slot, ground wire. Slot Y, red wire. Slot X, black wire. Slot W, white wire.


How do you connect your range to a three prong outlet?

A range, when purchased new, can be supplied with either a 4 prong plug or a 3 prong plug. It is the purchaser's choice and when you bought a new range, the seller should have asked you which type you need. If he didn't, you should go back and have him provide a new 3 prong cord and plug in exchange for the new 4 prong type.If the range was not purchased new, you'd have to purchase a 3 wire cord and plug at a home store or electrical equipment supplier and change the cord. There will be instructions in the back of the range when you open it up advising how to change the cord and showing how to hook it up to a 3 wire outlet. It is much better - and safer - to upgrade the outlet to a 4 prong version. The requisite wiring may already be in place. For a 240 Volt range you need two "Hot" wires (red and black), a "Neutral" wire (white) and a Ground wire (green or bare copper wire). If that wiring is not already in place, you'll need to rewire the range supply circuit from the breaker box to be safe. It will be a either a small job or a large job but, either way, necessary. For more information see the answer to the Related Question shown below.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.If you do this work yourself, always turn off the powerat the breaker box/fuse panel BEFORE you attempt to do any workANDalways use an electricians test meter having metal-tipped probes(not a simple proximity voltage indicator)to insure the circuit is, in fact, de-energized.


What cable will hook my PDA to my laptop?

Depending on your PDA, you'll need either a 3 prong or a 4 prong cable with a UBS on the other end.


How do you hook up a three prong outlet for an electric stove with a 50A outlet?

This is a common topic here. Firstly, if you are installing new work go with a 4 prong oven outlet. 3 prong outlets are old and do not meet code for new work. To install, you need to run 6/3 romex wire from your main panel to your new outlet. Install the new outlet in a box behind your oven. Wire up the 6/3 in the panel to a 50A 240V breaker. Remember the color code: Black/red/brass screw is hot, White/silver screw is neutral, bare wire/green screw is ground. I also recommend buying a book on Home Electricity repairs. It will show you how to do it right and serve as a handy reference during the job. As always, do it right or hire someone to do it for you. Negligence is fatal with electricity.


Can you convert 4 prong dryer cord to 3 prong?

Probably not. The reason is the amperage required by the electric range. They typically require 50 amp whereas a dryer normally only requires 30 amp. Therefore, the wiring feeding the dryer is not large enough to support an electric range. Your range should be wired with #6 or 8 gauge wire, whereas your dryer is likely only wired with # 10 gauge which will not carry 50 amps.


How do you hook 230v air compressor to house?

You would have to install a 230 volt outlet.


Does the electrical wall outlet half to be same hook up as hook up at box?

Yes, black is hot, white is neutral, and copper is ground.


How do you hook up a garbage disposal and a dishwasher to the same outlet if the outlet has black red and white wires?

each needs a separate 20 amp feed