The following procedure tests for a short to voltage in a circuit.

1. Set the rotary dial of the DMM to the V(DC) position.

2. Connect the positive lead of the DMM to 1 end of the circuit to be tested.

3. Connect the negative lead of the DMM to a good ground.

4. Turn ON the ignition and operate all accessories.

5. If the voltage measured is greater than 1 volt there is a short to voltage in the circuit.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you test for short to voltage?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Why high voltage is kept open in open circuit and low voltage is shorted in short circuit test?

In Short circuit test High Voltage side is feeded with 2-5% of the High Voltage rating to circulate approximately full load current in low voltage winding by short circuiting it. Low voltage is generally short circuited to facilitate measurements because it is more difficult to measure the quantities at high voltages.


Why do you put the meters in the high voltage side in the short circuit test?

in the short circuit test we applied supply voltage on L.V side and short circuit the H.V side and connect the ammeter in H.V circuit to measure the short circuit current. with the help of s.c test we measure the copper losses in the transformers.


Why were instrument of a transformer placed on a high voltage side in short circuit test?

I assume "tension" in this question should be replaced with "voltage". Short circuit tests are often performed from the lower voltage side of the transformer, since a lower voltage source is then required to perform the test. Often times the test lab may not have a source that can output a high enough voltage to perform from the high voltage winding.


Why open circuit test is performed on low voltage side?

generally open circuit test is performed on the low voltage side.....not on high voltage side.... becuase on low voltage side, we can apply that low voltage very easily ( i.e with a less amount of source is required)... whereas on high voltage side, we need a large power source in order to apply full voltage... in short circuit test, we will test on high voltage side by keeping Low voltage side being short circuit.because high voltage side needs less current source than low voltage side....


What are the types of power transformer test?

open circuit & short circuit test, insulation resistance test, turns ratio, efficiency, if it is oil cooled then breakdown voltage of oil, voltage regulation and definitely visual inpection...


Why the iron losses absent in short circuit test?

Because a short-circuit test is done at very low voltage to check the transformer windings on their maximum current. The low voltage ensures that the magnetic flux in the transformer's iron core is very low so that the eddy-current losses, usually known as iron losses, are negligible.


Why short circuit test is done at high voltage side?

1)Short circuit test is performed at rated current. As the rated current on high voltage side is much less than low voltage side, so the rated high voltage side current is easily achieved compared to low voltage side. 2)Also because we cannot short circuit high voltage side, as, if we short circuit high voltage side, voltage of high voltage side essentially falls to zero and since VI=constant, so the high voltage side current will be very high and will burn the winding.


What is the voltage volts for the throttle position sensor and where does the voltage come from on a 94 potiac grand am?

the voltage "persay" comes from the ecu(computer) i would not use a test light to see if voltage is present thay can be intrusive and short the ecu u will need a dvom meter and service manual to test that circut


What will happen to the transformer if the rated voltage is applied to the winding during short circuit test?

the winding would burn....


Why in slip test the machine voltage reduced?

The low slip test is used to determine the D and Q axis impedance of salient pole machines. The machine terminals are short circuited, each phase voltage and current are measured. Since the terminals are short circuited, machine voltage must be reduced to prevent excessive output currents that would damage the machine.