answersLogoWhite

0


Best Answer

In most rooms they must be spaced no more than 12 feet from each other. In kitchens, they should be spaced about 4 feet from each other.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

9y ago

The electrical code states that there be a radius of 6 feet from each outlet to the next. In linear measurement this means that there should be a receptacle every 12 feet.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How many electrical outlets per wall?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

How many lights off one switch?

ten lights per curcuitCircuit loadingIn Canada there shall be not more that 12 outlets on any 2 wire branch circuit. Such outlets shall be considered to be rated at not more that 1 amp per outlet. Where the connected load is known, the number of outlets may exceed 12 providing the load current does not exceed 80 % of the rating of the over current device protecting the circuit.


How much electrical energy does the average American require per day?

How much electrical energy does the average American require per day ? How much electrical energy does the average American require per day ?


How many outlets can you have on a gfi breaker?

Depends on the breaker. If the load at the outlets is unknown then the standard rules of 80% apply. You can only load a circuit 80% of it's maximum value. For instance, if you're connecting your GFCI outlets to a 15 amp breaker you can only have a maximum of 12 outlets. If it's a 20 Amp breaker then you're allowed up to 16 outlets and so on. In the US, you are limited to 13 receptacles on a 20 amp circuit and 10 receptacles on a 15 amp circuit in commercial or industrial installations. Any or all of these can be gfci-protected. You can install one gfci, the first one from the panel, and protect any or all the others from that one.


What is a 20 amp breaker?

For residential occupancy there is no code for the number of outlets. It depends on the load that is going to be applied to these outlets. In an average bedroom I would limit the outlets to no more than 12 unless it is going to be used as an office. In that case limit it to 10. If the lights are on the same circuit then limit it to a combination of 12 counting the lights and outlets. For a residential occupancy, there is no Code limit or load per receptacle. The number of required branch circuits is determined by calculations stated in article 220 of the nation electrical code and are related to square footage. Certain branch circuits, such as kitchen, laundry, and bathroom cannot serve other areas. That said, it is good practice to limit the number of general purpose lighting and general purpose outlets per circuit. Your local inspector may choose to be more stringent than the actual Code requirements.


What is the standard screw size for an electrical socket ie to screw it to its metal box mounted in the wall?

The screw size is a 6-32. This relates to diameter size of #6 and 32 threads per inch. The length for receptacles is usually 3/4 of an inch.

Related questions

How much do contractors charge to build a wall?

It Depends: 1.) What kind of wall do you want? (wood, brick, concrete, mud, etc.) 2.) What typed of wall is this? (Interior, exterior wall of house, exterior landscape/utility wall) 3.) What is the wall finish? (drywall, stucco, siding, plywood, T111) 4.) How tall, thick and wide is it? 5.) does it already have a foundation? 6.) What is the wall tying into? If you're just talking a about an interior partition wall that will be drywalled, you're looking at about $60 per lineal foot with per code electrical outlets.


What does it cost per electrical repeptacle installation in Edmonton Alberta?

$25.00 per receptical is what I charge if the wall is open


What is the minimum number of outlets in a room?

1Answerone There has to be an outlet for every 12 linear feet of wall space without an entry intervening. So say you had as 12 ft. by 12 ft. room and a door was in corner. If you put an outlet on the center of each wall that would be the minimum per code.


What is the price per meter of electrical wire?

The price per meter of electrical wire depends on many things like the size, type and many others. The prices vary from $0.1 per meter to $200 per meter.


How many sunny days per year in st george Utah?

Clear wall to wall sunshine per year 309


How many per cells in cell wall?

One.


How many beats per minute in the wall by Pink Floyd Floyds the wall?

100 BPM


How many bricks required for 1 square meter wall?

60 per single thin wall.


How many people surround the Wailing Wall per year?

In 2010 there were about 10 million visitors to the Wailing Wall.


How many tourists does the great wall have per day?

6000 a day.


What is the formula for heat flow per unit time through a single layer wall?

Heat flow per area per time = (delta T) / R delta T = difference in temperature between the two sides of the wall area = area of the wall or part of the wall under consideration 'R' = "R"-value of the construction materials and/or insulation that makes up the wall. Intreresting how it's the direct analog of Ohm's Law for electrical voltage (delta T), current (heat flow per time), and resistance ('R').


Why are 12 lights permitted on a circuit?

The electrical code states that there shall not be more than 12 outlets on a two wire branch circuit. Such outlets shall be considered to be rated at not less than 1 amp per outlet.Where the connected load is known, the number of outlets shall be permitted to exceed 12, provided that the load current does not exceed 80% of the rating of the over current device protecting the circuit.