if you lost one or two fan speeds you need to change the blower motor resister. it sells for around $60.00 at a dealer only.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How test Chevy Trailblazer blower switch?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do you remove heater motor from 2006 Chevy Trailblazer?

It's right behind the glove box. However you must be sure that it is not he fuse or the blower motor resistor that has gone out on you first. You can test the blower motor with 12V power as that is what it gets on high speed. www.trailvoy.com Trailblazer enthusiasts forum.


Why is your outlet for the diagnostic test in your 2003 Chevy Trailblazer dead?

check fuse


Why won't a Chevy Impala blower motor turn off?

The switch is out or you have crossed wires-it's still getting current. Use a test light with switch off on hot wire between switch & motor. If there is current, your switch is bad.


Why would a blower motor not work in a 1996 Chevy blazer. I did check the fuse.?

Either a broken wire - faulty switch - or bad ground. You're going to need a test light to find the fault here. Is there power to the hot side of the blower switch? Does power transfer to the cold side when the switch is turned on. Is power reaching the blower. Blowers rarely fail BUT it can happen.


Blower motor stop working in 1998 Chevy silverado?

Well you got ten years out of it. Put in a new one. Fuse??? Take a test light and see if there is power to the blower. Had this problem on my 1998 silverado with blower working on only high speed. Replaced the resistor, relay, and motor. Didn't help. Finally decided to use a test light to check for power. Started at connection supplying power to the blower motor switch then checked for power at each blower switch speed connector. Bingo! Bad switch. www.napaonline.com/masterpages/NOLMaster.aspx?PageId=470&LineCode=ECH&PartNumber=HC1...


The Heater blower has stopped working - How do you troubleshoot the switch and repair on a 1995 Ford Escort?

You've got to use a test light to see if there is electricity getting to the switch. First check to see if it's getting past the fuse - then to the switch with the switch off - then through the switch with the switch on - finally to the blower motor.


What causes the blower fuse to instantly blow in a 99 Chevy blazer?

Short in the circuit somewhere. Try unplugging the blower motor, closing the circuit with a test lead or test light, and seeing if it blows then. If not, the problem would seem to be in the blower motor itself.


What safety rating did the Chevy Trailblazer receive?

The Chevy Trailblazer received a Acceptable rating from the Insurance Institute for Highway Safety, while the National Highway Traffic Safety Administration's crash test ratings ranged from three to five stars (out of five) depending on the seat.


How can you tell if the cylinder head on your 2003 Chevy Trailblazer is cracked?

inspect, look, listen, clean and feel A compression test will also help.


How do you test a resister in a blower?

To test the blower motor resistor, unplug the resistor connector. Each blower motor switch input terminal on the resistor must have continuity to the resistor output terminal, which is connected to the circuit going to the blower motor. If the blower motor resistor continuity does not check OK, replace the faulty resistor.You need a multimeter to test the resistor block and there should be continuity between all terminals.


How can you fix gas gauge in 2006 Chevy Trailblazer?

Have a mechanic test the fuel sensor circuit. Likely the sensor has gone bad and will require replacement.


On a 1992 town car the floor heat does not work but all other positions on climate control work?

No Blower in Floor Mode A customer arrives with a 1983 to 1995 Full Size Ford, Lincoln, or Mercury automobile with automatic temperature control. If the complaint is no blower operation when the floor mode is selected, the vehicle may have a problem with the thermal blower lockout switch also referred to as the CELO (cold engine lock out switch). The thermal blower lock out switch is located in the heater core intake hose. The two wire switch has a thermal element with a small set of contacts, the contacts are open when the coolant is below 120°F and closed when the coolant is above 120°F. The thermal blower lock out switch also contains a vacuum switch, which applies vacuum to the outside/recirculate valve when the system is in the floor position. When the engine coolant is below 120 degrees and the selector is set to floor position, the thermal blower lock out prevents blower from turning on and closes off the outside air during engine warm-up. When the coolant temperature is above 120 degrees, and the selector is set to the floor position, the thermal blower lock out switch allows the blower to operate and opens the outside air door. In order to diagnose this problem, test the thermal blower lockout switch with the engine at normal operating temperature (above 120°F). Unplug the wire harness connector from the thermal blower lockout switch. Using a 15-amp fused wire, jumper the harness terminals to test the switch. If the blower comes on, the thermal blower lock out switch is faulty. If the blower doesn't come on, look for an open between the control head selector and thermal blower lock out switch. In some cases the blower may continually run even when the engine temperature is below 120 degrees. Unplug the thermal blower lock out switch and if the blower motor turns off, the thermal blower lock out switch is faulty. If the motor continues to run, look for a short to power between the control head selector and thermal blower lock out switch