The easiest way to control any electric current to any device is with the inline use of either a manual or electric reistate.
The part that opens the circuit is the overload blocks that are situated below the magnetic starter and before the motor load. The latest addition to the electrical code book states that the "hot" wire goes through the overload contacts first before feeding the 3 wire control system. With the supply voltage in this position the whole circuit becomes de-energized when the motor load trips the circuit. The old standard practice on a 3 wire control system, the neutral was connected to the overload relay contacts. When the overload relay tripped it opened the neutral of the coil circuit and the starter dropped out
The star delta motor starter circuit has to have a control voltage to energize the motor magnetic contractors. A phase failure relay monitors all three phases of the incoming supply lines. The phase failure relay also has auxiliary contacts on it. There are usually two sets of "C" form contacts. The control voltage for the starter circuit must be connected across the normally open (N.O.) contacts of one of these two sets. When the phase monitor is energized these N.O. contacts close supplying the control voltage to the circuitry of the star delta starters. If there is a phase interruption, phase reversal or phase loss, the phase failure relay will de-energize and the N.O. contacts will go back to their de-energized state. If the star delta motor starter is in use at the time, its control circuitry voltage will be lost and the delta motor magnetic contactor will open. The opening of this contactor will disconnect the motor from the failed three phase supply.
to turn electrical potential into mechanical work/motion.
Any specific device that draws a current which is connected within the circuit is an example of a circuit load. That may be a resistance and a loudspeaker LED computer and induction motor or whatever which can withdraw the energy from the output.
Yes, just reverse the start winding circuit.
A three phase motor control circuit.
The flux control method is the convectional and the non-convectional method of speed control of an induction motor.
Remote-Control Circuit. Any electrical circuit that controlsany other circuit through a relay or an equivalent device.
there are two methods i.e armature control method and field control method....
The breaker should be sized to 250% of the motor's full load amperage.
It is proper "control sense" to fuse the control circuit. It does not have to be just a cartridge fuse, in many cases it is a breaker. Depending on where the control voltage is obtained from, transformer from the incoming motor feed, separate source, or line voltage, there is always a chance that a component of the control circuit could fail, circuit protection would lessen the damage to other equipment in the control circuit. The fuse should be sized as close to the control current as possible.
speed of a dc motor can be varied by mainly two methods:- 1)field control method 2)armature control method further , field control method can be divided in 3 parts:- 1)field rhestat control method---speed variation is acomplished by means of a variable resistance inserted in series with shunt field 2)reluctance control method---by changing the reluctance of magnetic circuit by choosing right material.. 3) field voltage control method-requires variable field voltage supply. and armature control method can be divided in 3 parts :- 1)armature resistance control---variable resisitance connected in series with armature 2)shunted armature control. 3)armature voltage control. ------------mrityunjay pandey (kiit university ,btech 2nd year)
How many methods can be used to control the speed of Single Phase Induction Motor? 1.injecting emf method 2.by frequency control method 3.induced voltage method
By using your brain
True synchronous mode and self control mode
A simple electrical circuit consist in a source of power (like a battery), a conductor (like a wire), and a load (like a light bulb, a motor, a resistor, etc)
you can control the speed of a motor by changing frequency, increase or decrease the field winding or by voltage regulation. in these method you can controle the speed of athree phese motor SANDEEP SARKAR