Limit state design is designed a concrete member for its various damage limit states, concrete sover spalling, steel yielding all the way up to the crushing of the concrete core, with this you can control how you want the concrete member to fail.
Yes we can use limit state design for water tank design....
Working stress method of design based on the elastic theory in which materials, concrete and steel are assumed to be stressed well below their elastic limit under the design loads. Working stressess (permissible stress) for the materials are determined by dividing the ultimate or yield stressess by suitable factor of safety values. Limit state method of design based on limit state concept, te structure shall be designed to withstand safely all loads liable to act on it throughout its life;It shall also satisfy the serviceability requirements, such as limitations on deflection and cracking. The acceptable limit for the safety and serviceability requirements before failure occurs is called a "limit state". The aim of design is to achieve acceptable probabilities that the structure will not become unfit for the use for which is intended, that is that it will not reach a limit state...
Limit state design
because by these method all loads are considered ,and the structure is designed to undergo these loads
no..it will be in liquid state and after it reaches its settling time, concrete starts hardening and finally to solid state...
in reinforced concrete design
P. E. Regan has written: 'Limit state design of structural concrete' -- subject(s): Plastic analysis (Engineering), Reinforced concrete construction 'Punching shear in prestressed concrete slab bridges'
Derrick Beckett has written: 'Bridges' -- subject(s): Bridges, History 'Limit state design of reinforced concrete structures' -- subject(s): Reinforced concrete construction, Plastic analysis (Engineering) 'The centenary of the Forth Rail Bridge (1890-1990)' 'Brunel's Britain' -- subject(s): Civil engineering
B. P. Hughes has written: 'Elimination of shrinking and thermal cracking in a water-retaining structure' 'Limit state theory for reinforced concrete design' -- subject(s): Plastic analysis (Engineering), Reinforced concrete construction 'Control of thermal and shrinkage cracking in restrained reinforced concrete walls'
Charles Kandall has written: 'Elementary design of structural steel and reinforced concrete with solutions of structural design problems given in examination for licensed professional engineer in N.Y. state' -- subject(s): Reinforced concrete, Structural Steel, Structural analysis (Engineering)
Yes we can use limit state design for water tank design....
Working stress method of design based on the elastic theory in which materials, concrete and steel are assumed to be stressed well below their elastic limit under the design loads. Working stressess (permissible stress) for the materials are determined by dividing the ultimate or yield stressess by suitable factor of safety values. Limit state method of design based on limit state concept, te structure shall be designed to withstand safely all loads liable to act on it throughout its life;It shall also satisfy the serviceability requirements, such as limitations on deflection and cracking. The acceptable limit for the safety and serviceability requirements before failure occurs is called a "limit state". The aim of design is to achieve acceptable probabilities that the structure will not become unfit for the use for which is intended, that is that it will not reach a limit state...
limit state method
It is a constraint
Working stress method of design based on the elastic theory in which materials, concrete and steel are assumed to be stressed well below their elastic limit under the design loads. Working stressess (permissible stress) for the materials are determined by dividing the ultimate or yield stressess by suitable factor of safety values. Limit state method of design based on limit state concept, te structure shall be designed to withstand safely all loads liable to act on it throughout its life;It shall also satisfy the serviceability requirements, such as limitations on deflection and cracking. The acceptable limit for the safety and serviceability requirements before failure occurs is called a "limit state". The aim of design is to achieve acceptable probabilities that the structure will not become unfit for the use for which is intended, that is that it will not reach a limit state...
Limit state design
working stress: in this a structure is designed by considering the stresses in its working condition..Limit state: In this the structure is designed by considering the stresses at different limit states. there are two limit states. ultimate limit state (situation in which structure collapse) and servicability limit state (situation in which cracks etc appears.)