What gauge romex for outlets?

Updated: 8/11/2023
User Avatar

Wiki User

11y ago

Best Answer

Romex is a manufacturer's wire cable trade name, the 10 refers to the size of the wire inside the cable set. A #10 AWG copper conductor with an insulation factor of 90 degrees C is rated for 30 amps.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

12y ago

ROMEX® is a federally registered trademarked brand of non-metallic sheathed electrical cable originally developed by the former Rome Wire Company in 1922. The ROMEX Brand is now owned and produced by Southwire Company.

This answer is:
User Avatar

User Avatar

Wiki User

13y ago

Romex is a manufacturer's wire cable trade name and not a wire size.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What gauge romex for outlets?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What wire is commonly used in house wiring?

Romex, All you have to do is go to a hardware store and tell them you need house wire. It comes in a box. I am not sure how many feet. If you are just looking for the gauge, they will know that too.


Can you use 10 gauge wire to connect a 2 15 amp outlets to a 30 amp breaker?

no


Can you add 14-2 romex wire to old house wiring?

Yes, if the existing wiring you are adding to is 14 gauge. If it is 12 guage then you must use 12 gauge. If you are running wire from the service panel it is fine as long as you install a 15 amp breaker.


How many watts and romex gauge is safe for a 15amp breaker?

Assuming 120 VAC in a residence maximum watts = 15 x 120 = 1800 Watts. For a continuous load you can support 1440 watts which is 80& of maximum. You need 14 AWG gauge wire.


WDR type outlet?

A fire trap outlet used in motor homes. The wire self pierce romex conductors with a small contact friction contact. These should be replaced with quality screw terminal outlets in outlet boxes.


If a 1950 era house has 10 gauge wiring for lights and outlets can you safely extend wiring with 12-2 for additional lights and outlets?

You can provided the protecting breaker for the circuit is 20 Amps or less.


Is romex pure copper?

Copper or aluminium.


Can 15 amp rated outlets be used with twelve gauge wire?

A. It's 240 volts & B. Wire size is a function of amperage. 12-gauge wire is used with 20 amperes or less. So, 12-gauge wire can be used with 120V/20A or 240V/20A. Keep in mind though that 240V in the U.S. has 2 live 120V lines so if you encounter a white wire, it's probably an unmarked live & should be repainted as black or better yet, red (to indicate the 2nd live wire).


What size romex for 5000 watt dryer?

Assuming 220 volts service 5000/220 = 22.72 Amps. That equates to 10 AWG Romex.


What is the difference between 15 amp and 20 amp service?

It is the rating of how much current you can deliver to loads on a circuit. For example, if you had 10 outlets on 20 A service that is what you could run from the outlets on a circuit. This is a total capacity and not the capacity of each outlet on the circuit. If you plugged something into an outlet that drew 20 A you wouldn't be able to run anything on other outlets. In a lighting circuit two 60 W incandescent bulbs draw one amp. Therefore, on a 15 A lighting circuit you could have a maximum of thirty 60 Watt bulbs. Usually you try and stay at about 80% of rating so practically you could have 24 bulbs. ponypomp; 5 amps. A 15amp breaker is used with 14ga romex wire, designated in homes for lighting. Common practice. A 20amp breaker is used with 12ga romex wire ,designed for the outlets in a home. Common practice. Just wanted to add this to the great post above.


What is the difference between thhn and romex?

THHN is a heat resistant thermoplastic insulated conductor, usually a single conductor. Romex is a brand name for a nonmetallic sheathed cable, it has multiple conductors inside, the insulated ones are insulated with THHN insulation.


Can rodent damaged romex cause gfci to trip?

Yes