Best Answer

Both are types of isolators of a power circuit. Load break switch is an isolator where circuit can be isolated on load. The quenching media could be air, oil or gas.....

Air break switch is type isolator where isolation takes place in the air itself. (break contacts are not immersed in oil, gas ...) But whether these isolators can be opened on load or not can be said only by looking at the desgin data. Some isolators are designed to open and close on load.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is difference bitween air break switch and load break switch?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is on load and off load switching?

On load switching is when a switch can be operated whilst current is still passing through the switch (i.e. it is on load) Offload switching is when a switch is operated whilst there is no current through the switch (i.e. it is offload)


What is the least destructive load to switch?

No load is the least destructive load to a switch.


What is Disconnector Switch?

to disconnect the circuit when faults occursAnswerA 'disconnector switch' is another term for an 'isolating switch' or 'isolator'. It is a manually-operated switch used to provide a visible break between a de-energised part of a circuit and the energised part of a circuit so that work can be carried out safely on the de-energised part. A disconnector switch is not intended to break a load current, and most certainly not designed to break a fault current -that is the function of a circuit breaker.


Difference in dimmer switch heat 600 watts or 1000 watts?

A dimmer switch is used for lighting loads and not heating loads. The wattage rating on a dimmer switch is what the manufacturer recommends as the maximum load that the switch can handle. For example if you have ten 100 watt lamps, the total load wattage would be 1000 watts (10 x 100). Too much load for a 600 watt rated dimmer switch but not for a 1000 Watt rated dimmer switch. So you can see that the rating on a dimmer switch governs the maximum wattage load that can be connected in the circuit that is to be controlled.


Why the isolator should not closed with load?

Isolation switches can be closed with loads connected. The isolation switch should not be opened under load unless the switch is load rated. This information can be found on the isolation switch's cover as to the amount of current that can be safely interrupted.

Related questions

What is the difference between a load break switch and an air break switch?

The main difference is that air break switches lack a mechanism for suppression and load break switches do have them. They are both disconnect switches but have different uses.


What is the difference between load break switch and ht switch fuse unit?

Both are same...


What function in a circuit for a switch?

A switch is a make - break device. Its function is a circuit is to make and break the current flow of the circuit that it is in. This action then starts and stops the load that is connected in the circuit.


What is break load?

TPN Load break switch: Is basically a main switch used in three phase system and know as Three pole neutral or Three phase neutral having four connectors for three phases and one neutral.


Does opening a switch break an electric device?

No, it opens the supply voltage and hence the supply current to the load.


Why does some equipment only need a single pole switch while other equipment needs a double pole switch to operate?

Answer for USA, Canada and countries running a 60 Hz supply service.The type of switch is dependant upon what voltage the load uses. If a load is 120 volts, the electrical configuration is one hot line and one neutral. To break this load a single pole switch is used to break the one hot leg. Neutral wires are never to be opened. If the load is 240 volts, the electrical configuration is two hot legs. To break this load a double pole switch is needed to break both hot legs. A single pole switch will break the load but not safely. If you were to work on a 240 volt system with just one leg broken, the voltage from the second hot leg could feed back 120 volts to the ground. If you got between this voltage, a nasty shock could be given. So it for safety reasons that on 240 installations both lines are broken with a two pole switch.


What is on load and off load switching?

On load switching is when a switch can be operated whilst current is still passing through the switch (i.e. it is on load) Offload switching is when a switch is operated whilst there is no current through the switch (i.e. it is offload)


What is the difference between an air break switch and an isolator?

An air-break link (ABL) switch is designed to interrupt normal load currents (but not fault currents). In order to do so, they usually incorporate some form of very simple arc-extinguishing feature.An isolator switch, on the other hand, is not designed to interrupt current, but to isolate equipment after that equipment has been disconnected (e.g. by opening a circuit breaker).


What is the least destructive load to switch?

No load is the least destructive load to a switch.


What is the difference between Load Break Switch and Circuit Breaker?

There are two important different parameters as far as the disconnection/connection of Electrical utilities is concerned.- Breaking capacity.- Making Capacity.In simple way the Load Break Switch used to cut off healthy circuits or to break / disconnect the load. As a precaution, normally the LBS / Isolator are to be switched on under no load, the connected load to be utilized after switching on the Isolator. This why it has no making capacity. Circuit Breakers are intended to operate under unnormal conditions in order to clear the fault & to isolate the defective circuits protecting its associated electrical equipment, therefore breaking and making capacities are considered as the most important criteria as far Circuit breaker are concerned.


What is function of load break switch?

A load break switch is a disconnect switch that has been designed to provide making or breaking of specified currents. This is accomplished by addition of equipment that increases the operating speed of the disconnect switch blade and the addition of some type of equipment to alter the arcing phenomena and allow the safe interruption of the arc resulting when switching load currents.Disconnect switches can be supplied with equipment to provide a limited load switching capability. Arcing horns, whips, and spring actuators are typical at lower voltages. These switches are used to de-energize or energize a circuit that possesses some limited amount of magnetic or capacitive current, such as transformer exciting current or line charging currents.An air switch can be modified to include a series interrupter (typically vacuum or SF6) for higher voltage and current interrupting levels. These interrupters increase the load break capability of the disconnect switch and can be applied for switching load or fault currents of the associated equipment.


What is Disconnector Switch?

to disconnect the circuit when faults occursAnswerA 'disconnector switch' is another term for an 'isolating switch' or 'isolator'. It is a manually-operated switch used to provide a visible break between a de-energised part of a circuit and the energised part of a circuit so that work can be carried out safely on the de-energised part. A disconnector switch is not intended to break a load current, and most certainly not designed to break a fault current -that is the function of a circuit breaker.