In regenerative cycle LP/HP heaters are used to raise condensate/feed water temperature by extracting/bleed steam from LP and Hp stages of steam turbine in order to improve the efficiency of the plant
room heaters have polished surface
Yes, the tankless water heaters do cost more than the normal water heaters because tankless water heaters are designed to supply hot water only when needed unlike normal ones.
By the phrase "trips the heaters" I am assuming that you meant the Overloads. There are 3 possible answers: 1) The Overloads are not the correct size or are in a high ambient temperature envornment. Most manufacturers have sizing charts that take these into account. 2) The motor is bad or in the process of going bad. 3) The motor is overloaded. If you are running a 7 1/2 HP motor on a load that requires 10 HP then the motor will draw too much amperage and trip the overloads.
it depends on the whether when the solar power heaters work
Solar heaters are useful for heating water with natural energy, thus saving electricity. The question is can effective solar heaters be made for less cost than using the electricity.
See: How Safe are Vent Less Heaters
HP Turbine is High Performance Turbine LP Turbine is Low Performance Turbine
HP used for high pressure well and LP for low pressure well in oil and gas industries.
hp dosing used for precipitate the silica from bfw in drum and lp dosing used for increase the ph in boiler to maintain 9.5 to 10.5
in an hp supercell high amounts of hail and rain obscure everything and often hide tornadoes that are inside of them. they make tornadoes nearly impossible to see. an lp supercell has very little percipation and due to that doesn't have a tornado as often as an hp. however an lp supercell has great visibility.
LP Compressor PackageSource of LP gas is either from GC-16 (LP+TV) or from GC-28 (from LP Separator KO Drum). The LP gas transfer line carrying the LP+TV of GC-16 is routed to a new LP Gas Inlet Manifold, near TP-4 with pigging facilities to absorb the slamming actions of liquid slug, etc. at either end of the pipeline (namely in the vicinity of GC-16 and TP-4). The pig receiver and all other reliefs including common LP scrubber relief shall be integrated into the flare header of the GCP. The LP pig launcher relief goes to the existing flare in GC-16.The Common LP Scrubber is designed for handling liquid slug during pigging and normal operation. The scrubber is provided with automatic level control valves and collected liquids are routed to the LP Compressor Closed Drain Header.The GCP LP Compressor compresses the incoming gas from 20-60 psig to 270-300 psig and transfers the discharged gas to a 30" HP compressor suction manifold. The gas is compressed through a three-stage reciprocating compressor.HP Compressor PackageHP Gas from GC-16 is branched off through a new HP Scrubber to a new HP gas transfer line (approximate distance 3.5 KM) between GC-16 and TP-4 near GC-28. The line is equipped with pigging facility. HP gas may also come from the GC-28 HP Separator KO Drum.All sources of HP gas join in a Common HP manifold before going to the Common HP Scrubber. The HP Common Scrubber is provided with automatic level control valves and collected liquids are routed to the HP Compressor Closed Drain Header. HP Gas is routed to the HP Gas Suction Scrubber within the compressor package. The GCP HP Compressor compresses the incoming gas from suction pressure of 210-260 psig to discharge pressure of 900-1,000 psig. The gas is compressed through a three-stage reciprocating compressor.
they heal 230 hp, they also can heal you up to 100 hp over your standard maximum. Note, this will not be accurate in the long term due to the evolution of combat update which will be coming later.
Ratio 50:1 lp marko
One can purchase a cheap lp propane heater on eBay, the website lowes, propane101, air-n-water, homedepot, grainger or even Amazon. There are also local stores that sell them.
the propane company says that it can not be converted to natural gas because of the laws and government regulations
1 HP = 2446 btu/hr and 1 kWh=3413 btu/hr so 1kWh = 1.413 HP, thus 45kWh x 1.413 = 63.585 HP.
Simple answer: 100 pounds of Propane => 100 / 4.24 = 23.6 gal the "standard" LP cylinder for a gas grill is 20 pounds = 4.7 gallons The conversion for LP is Gallons x 4.24 = Pounds if one is trying to compare LP to gasoline, one must also consider that LP provides about 80% of the energy of gasoline. In a small portable generator, it is nearly transparent, but if one wishes to convert a car to LP one gets less mpg and hp.