answersLogoWhite

0


Best Answer

It depends on which Directive the vessel has to be compliant with. For instance, to comply with CE/PED, the test pressure shoud be 1.43 times the maximum operating pressure.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the criterion for deciding the hydro test pressure in relation to the design pressure of a pressure vessel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Mechanical Engineering
Related questions

What is the main criterion for the design of digital circuits?

The main criterion for the design of digital circuits is to simplify your circuit so you don't get to use so many circuit elements there by improving upon the propagation delay of the circuit in effect.


How do you convert a pneumatic test pressure to a hydro test pressure?

Design pressure multiply by 1.1 equal pneumatic test pressure. Design pressure multiply by 1.5 equal Hydrotest Pressure Note: Design Pressure is different from Operating pressure. Design Pressure is equal to Maximum Operating Pressure From: galdo.gaspar@ymail.com


How do you convert a hydro test pressure to a pneumatic test pressure?

Design pressure multiply by 1.1 equal pneumatic test pressure. Design pressure multiply by 1.5 equal Hydrotest Pressure Note: Design Pressure is different from Operating pressure. Design Pressure is equal to Maximum Operating Pressure From: galdo.gaspar@ymail.com


What is design pressure of LPG?

Design Pressure of LPG is nominally taken as 250Psi/1.725bar


Design pressure compare to working pressure?

who am i?


What is unit of differential pressure?

Let me differentiate first between design pressure and mechanical design pressure. Design (or discharge) pressure is the pressure at the outlet of the pump, the pressure you've designed the pump to deliver. The mechanical design pressure is a value that the pump casing and downstream piping have to be able to withstand as a minimum*. I presume you mean design pressure as discharge pressure. In this case, differential pressure is the difference between the discharge pressure and the suction pressure (the pressure at the inlet of the pump**). * this is calculated taking into account that a pump would be working against a 'blocked discharge' or a closed valve in the outlet piping ** imagine a reservoir filled with liquid


How a relation database design enables data to be organised and queried?

loool


What language used orthogonality as a primary design criterion?

LIPS a functional language is one in which computations are made primarily by applying function to given program


To create a parameter query enter a parameter rather than a specific value as a criterion in the design grid the parameter must be enclosed in?

Square brackets []


What criterion must be followed in the design of an IPv4 addressing scheme for end devices?

Each IP address must be unique within the local network.


What does function mean in relation to technology or design?

It means like how you would use it or what its for.


What is the size of a rectangular dining table pedestal in relation to its top?

The answer depends on the design.