Best Answer

its never a good idea to go to heavier fuse the potential exists for amp draw to be hig.h enough to damage a component or inaccessable wire

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the rule when dealing with fuses if you do not have a 30a can you use a 40a?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Will a 6V DC 40amp relay fail if 12V 30amp is applied to it?

Probably...The 6V 40A relay figures out as 240Watts...The same relay at 12V 30A figures out as 360Watts.


What fuse operates the driver seat on a 2001 Ford Windstar?

Fuse 104 (40A). Hope this helps! Fuses are detailed and illustrated in the Owners Manual - See "Related Questions" below for more


What is the US equivalent of European 4x2.5 sq mm HO7RN-F and could US 10 2 be substituted for the European cable to hardwire a 240V 27A appliance?

If you want an American plug to power a 30A 220V device look at a dryer outlet. It will have an extra neutral conductor, but it is standard. Otherwise, you can go with a 220V 30A TwistLok plug. All the home centers [I've been to] carry these plugs. 10ga wire is heavy enough for 30A runs under 75ft, though for a 27A appliance you should consider a 40A breaker with 8ga wire.


How do you calculate correct fuse rateing for electrical appliances?

if the appliance is manufactured after 1920 it will have a nameplate somewhere near the power connection. this nameplate SHALL have the amperage and voltage required. the fuses in a house are sized so as to not set the house wiring on fire. that being said water heater nameplate 28A 240V can be on for periods longer than 20 minutes (continuous duty) so must derated 10% 31A . minimum standard wire size #8 30A, 35A or 40A fuse no time delay needed. air conditioner 25A 120A LRA 240V minimum standard wire size #10 30A fuse time delay needed.


What is the greatest common factor of 40A and 36A?

4A


What are the release dates for The Electric Company - 1971 40A 5-40?

The Electric Company - 1971 40A 5-40 was released on: USA: 12 December 1975


Is 40a prime number?

no because it is an even number but not 2


What size wire for 40a breaker?

AWG # 8 copper


What is the amp rating on 10mm2 PVC PVC?

10mm2 : 40A


What is the purpose of a fuse in a mains circuit?

The main fuses protect the feeder lines from the electric company's feed to the main panel for the maximum ampacity rating of the wire. So depending on the size of the incoming tails nothing is gained by reducing the main supplier's cut-out fuse rating to 60A or 40A.


Where is the fuse located for the alarm system on a 1999 Mitsubishi Montero Sport?

Hopefully this helps I wasn't able to import a pic so I tried to duplicate it the best I could. 1 2 6 7 8 13 3 4 5 9 10 11 12 14 15 1 Dome Light 10A 2 Headlight upper beam 10A 3 Fog Lights 15A 4 Tail Lights 10A 5 Hazard warning flashers 10A 6 Heater Fan 30A 7 Air Conditioning 8 Fuse (+B) 40A...battery 9 Ignition Switch 40A 10 Power Window Control 30A 11 Headlights 30A 12 Engine Control 20A 13 Altenator 80-1 100-2 14 Condenser fan motor 25A 15 Air Conditioning compressor 10A This is for 2.4, 3.0 & 3.5 liter engine models...99 Montero Sport


What is this ditloid 40a - is D T?

40 all - is Deuce in Tennis 40 a Double Top (in darts)