What is the weight of a GFCI receptacle?

Updated: 8/17/2019
User Avatar

Wiki User

14y ago

Best Answer

8 ozs. and will vary by mfr. for an in-wall receptacle.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the weight of a GFCI receptacle?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can I install a GFCI receptacle from an existing receptacle in the basement?

Yes, there is no reason why this can not be done. In fact a benefit of this is that every receptacle downstream from this new receptacle will also be protected by the GFCI receptacle.


What might happen if the line and load connetions of a feedthrough gfci receptacle were reversed?

Most probably the receptacles downstream from the GFCI would not be protected by the GFCI receptacle.


Do you need a gfci outlet if you have a gfci breaker?

Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.


If your wall receptacle has tripped but not at the circuit breaker how can this problem be repaired?

If it's a GFCI receptacle and the button is not resetting then change the GFCI outlet.


If I have 20 amp GFCI receptacle and would like to add another receptacle to the GFCI Does the new plug also need to be 20 amps?

Yes.


How far do you put a GFCI from water?

How far do u put a GFCI receptacle from water


Will another electrical outlet that is in line with a GFCI outlet cause it to kick off?

A down stream receptacle that is connected to the upstream GFCI will be protected. If the downstream receptacle senses a fault the upstream GFCI will trip.


What does the term GFCI receptacle stands for?

The term GFCI stands for Ground Fault Circuit Interrupter.


How many amps does gfci trip at?

GFCI receptacle are designed to trip on 5 milliamps.


Can you install an electrical switch before a gfci?

Yes! you can install an switch a head of a GFCI receptacle. This installation is common in some applications to turn on an outside receptacle to control Christmas lights.


May a GFCI receptacle be installed as a receptacle in an old installation where the 2-wire circuit has no equipment grounding conductor?

Actually, yes. The GFCI does not need any ground; it measures "leakage", i.e., an imbalance, regardless of whether there is "ground". The National Electrical Code permits installing a GFCI to replace a completely ungrounded receptacle. Others have said: No. The GFCI is designed to measure an unintended path to ground. Without a good ground reference this is not possible.


Do you need a gfi plug for a spa if it is being plugged into a gfi circuit?

If your spa is connected with a GFCI circuit breaker you will not need the GFCI receptacle.