Blown fuse, defective heater control switch, bad resistor pack, loose or disconnected wire.

User Avatar

Wiki User

โˆ™ 2005-12-06 18:34:24
This answer is:
๐Ÿ™
0
๐Ÿคจ
0
๐Ÿ˜ฎ
0
User Avatar

Add your answer:

Earn +20 pts
Q: What would cause no power to the blower motor on a 1993 Ford Tempo?
Write your answer...
Submit
Related questions

What list of things should you check on 2002 Chevy blazer before you replace the blower motor?

The fuse. The blower motor speed resistor. The blower motor relay. The blower motor switch. Check for power at the blower motor connection.


No blower for AC or Heat 96 Escort Wagon. Fuse is good with Power at the Fuse box?

Blower motor located at the passenger side under the dash. Probably the blower motor but you need to check the blower motor resistor and the plug to the resistor. A common cause is the plug tends to melt & short out.


How do you know ac blower motor bad on 1990 Toyota?

If you have checked and the blower motor has both power and ground then the motor is bad.........


99 Taurus ac heater blower motor just stopped Fuses are good. Is it likely the Switch or blower motor?

Check to see if you are getting power and ground to the blower motor - if so blower motor is bad. If no power possibly fan switch or selector switch Also check the blower motor resistor, found in heater plenum.


If the blower stopped working my 2001 Kia Spectra could this be the motor blower resistor or should I replace the blower motor?

Check to see if you are getting power to blower motor - if so replace blower motor If not check fuse, switch, resistor pack.


The blower on your 1999 DeVille heater stopped working how can you determine if it is the blower or the control circuitry?

Check to see if you are getting power to the blower motor - if so motor is defective if not problem in circuitry to blower motor


Why isn't your blower motor working?

why does blower motor not work on 1984 Monte Carlo.It is new and it is getting power?


Does blower motor relay control power train too?

No only the blower.


2004 Chevy truck truck blower motor repair?

You gotta start by figuring out what's wrong with it. You need to determine if it's the blower motor itself, or the power supply, then troubleshoot to determine the exact cause.


What would cause the AC blower fan in a 1989 Caprice Classic to stop working?

The most common problems will be with either the power or the ground going to the the blower motor.................


Why doesn't Blower motor work on a 1998 Chevy Malibu?

Blown fuse? Bad blower motor? see if you are getting power to it Bad blower motor resistor? Bad switch?


What could cause the heater blower to stop working even after it and the heater control was replaced on a 1992 Ford Thunderbird?

You still have a blower resister assembly, wiring, and a blower motor itself, in that system. Any one of those could have a problem. You need to use a test light at the blower motor connector and see if you are getting both power and ground. If you are missing a ground, most likely you have a bad blower resister assembly. If you are mssing power, check fuses and wiring. If you have both power and ground, and the motor isn't working, you need a blower motor. I have also found that sometimes tapping with a screwdriver handle on the motor will make it come on, and if that is the case, then again, you have a bad blower motor.


What would cause the blower and AC to stop working while the battery charge light illuminates in the dashboard simulataneously?

A blower motor shutting off with a battery charge light lit might mean that there is a problem with the power supply going to the blower motor. A bad battery or alternator could also be the cause for this.


Why would the heater stop working in my 2001 jeep grand Cherokee?

blower motor bad or no power to it chech fuses blower switch blower motor


Where is the blower motor relay on a 1998 Cadillac deville?

A 1998 Cadillac Deville does not have a blower relay. The system has a fuse and a controller to feed power to the blower motor.


1990 Chevy Beretta heater fan not working fuses r good?

Check to see if you are getting power to blower motor--if so, bad blower motor If no power- perhaps bad resistor pack at blower motor Bad switch?


The blower motor isn't working on a 1999 Cadillac Seville the are no blown fuses or relays the blower motor does work whats the problem?

If you have checked the blower motor and it does function when power is applied then I would suspect the Blower Motor Resistor Pack is defective. It is also possible the blower motor speed control is bad, but highly unlikely.


I think I found the blower relay on my 97 escort behind the drivers side kickpanel I have power at the relay or fuse but I have no power at the blower switch what could be defective?

If there is current going through the wire to the blower switch, try bypassing the switch with a jumper wire. If the blower motor works, then replace the switch. If the blower motor does not come on, then you probably need to replace the blower motor.


What would the problem be when air bag light is on power windows and blower motor doesn't work but all the fuses are good?

It is possible that the power window motor and the blower motor are both faulty or that you have faulty wiring.


Where is the blower motor relay or blower control module on a 98 deville theres power going to the blower and the blower was tested it works fine but it wont come on in the vehicle?

Should under dash on firwall near blower motor.


Why is blower motor melting fuses?

the windings inside the blower motor can be shorted out fan will work but takes too much power could be a schafed wire as well or the blower motor could be seizing up..


Heater blower motor has no power 2006 g6?

Blown Fuse, loose or disconnected wire, or defective blower motor resistor pack.


Blower motor runs with ignition off?

probablly a bad ignition switch or blower motor not sure on that should run without power


2001 Pontiac grand prix heater not blowing?

Bad blower motor fuse? Bad blower motor resistor pack? Bad blower motor - checck to see if it is getting power--if so bad motor Bad switch?


I've got a 96' Dakota the fuses are good I've replace the blower motor and have power going to the plug in which you plugged the brand new blower motor into the blower motor still does not run wtf?

You have power but make sure that you also have a good ground and if so then you will need to check both the blower resister as well as the blower switch..........