answersLogoWhite

0


Best Answer

Use these numbers when bending offsets: 10 degree bends, multiply the depth of the offset by 6 this will give you the distance between bends. For 20 degree multiply by 2.6, for 30 degree multiply by 2, for 45 degree multiply by 1.4, for 60 degree multiply by 1.2. I use 30 degree bends for all of my offsets, just because its easier to do the math. So your answer would be 24 inches between bends. I have come to the conclusion anybody can bend conduit, its the measuring and marking that requires skill.

User Avatar

Darien VonRueden

Lvl 10
1y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: When bending a 12 inch offset using a 30 degree bend what would the distance between the two bends?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

When bending a 12 inch offset using 30 degree bends what would the distance between the two bends?

Use these numbers when bending offsets: 10 degree bends, multiply the depth of the offset by 6 this will give you the distance between bends. For 20 degree multiply by 2.6, for 30 degree multiply by 2, for 45 degree multiply by 1.4, for 60 degree multiply by 1.2. I use 30 degree bends for all of my offsets, just because its easier to do the math. So your answer would be 24 inches between bends. I have come to the conclusion anybody can bend conduit, its the measuring and marking that requires skill.


When bending a 12 inch offset using 30 degree BENDS what would be the distance between the two bends?

Use these numbers when bending offsets: 10 degree bends, multiply the depth of the offset by 6 this will give you the distance between bends. For 20 degree multiply by 2.6, for 30 degree multiply by 2, for 45 degree multiply by 1.4, for 60 degree multiply by 1.2. I use 30 degree bends for all of my offsets, just because its easier to do the math. So your answer would be 24 inches between bends. I have come to the conclusion anybody can bend conduit, its the measuring and marking that requires skill.


What does mean offset in the seismic data?

offset is the distance between the shot_point and the observing point.


How do you calculate a 22.5 degree offset?

i want to make 22.5 degree offset so how can i offset of 22.5make ritgh


Calculate 45 degree offset when the travel is known?

A 45 degree offset has a travel of 200mm. calculate the rise of the offset.


The loft of taylormade 2009 burner irons?

I found this information for the Taylor Made Burner XDs. * #4 (21-degree loft; 61.5-degree lie angle; 6.7mm offset) * #5 (23-degree loft; 62-degree lie angle; 6.3mm offset) * #6 (26-degree loft; 62.5-degree lie angle; 6mm offset) * #7 (30-degree loft; 63-degree lie angle; 5.7mm offset) * #8 (34-degree loft; 63.5-degree lie angle; 5.3mm offset) * #9 (39-degree loft; 64-degree lie angle; 5mm offset) * PW (44-degree loft; 64.5-degree lie angle; 4.7mm offset) * SW (49-degree loft; 64.5-degree lie angle; 2mm offset)


What is oblique offset in surveying?

offset that are not situated 90 degree rather that are situated in any angle like 60 degree or 45 degree


How many degrees of bend is allowed in a conduit run between j-boxs?

The electrical code states that there will be no more that four quarter bends between junction boxes. Keep in mind when conduit bending that an offset of two 45 degree bends is classed as a 90 degree bend. Offsets between two junction boxes uses up two of the four 90 degree bends allowed. If in a conduit run, the limit of 90 degree bends is utilized, always pull in stranded wire to make the pull go easier.


What is the multiplier for 45 degree offset in conduit bending?

Back set for all conduit sizes is not the same. The greater the diameter of the conduit the length of back set increases. Without the diameter size of the conduit, an answer can not be given.


How many degrees of bend is allowed in a conduit between boxes?

The electrical code states that there will be no more that 4 quarter bends between junction boxes. Keep in mind when conduit bending that an offset of two 45 degree bends is classed as a 90 degree bend. Offsets between two junction boxes uses up two of the four 90 degree bends allowed.In a conduit run between J boxes the number of bends can not exceed 360 degrees.The electrical code allows four 90 degree bends between pull boxes.


What is the offset when using a conduit bender?

The offset is the preset distance that is marked on the shoe of the bender. This preset mark allows for shrink back when bending. It allows you to make a perfect bend if a conduit run comes to a wall and has to go up the wall. It takes into account the outside diameter of the conduit and adds it to the shrink back of the bend to make the conduit fit exactly up against the 90 degree angle of the wall.See Sources and Related links below.


What multiplier would be used for EMT conduit to make a 45 degree offset bead?

The multiplier for a 45 degree bend is 1.4142 (rounded off to 1.4) times the height of the offset. All offset multipliers are the cosecant of the angle. (inverse of the sine of the angle). However, 45 degree offsets are very difficult to pull wire through and should be avoided. Always bend your EMT to the shallowest angle you can for the distance you have to do it in.