Fuses That "Blow" Repeatedly
Without being able to "hands on" troubleshoot the circuit served by the repeatedly blowing fuse, none of us can identify the specific defect which is causing your problem.
Therefore, the following generic answer can be applied to any electrical circuit, whether in a vehicle, or in a building, whether direct current [DC], or alternating current [AC].
Fuses [and Circuit Breakers] are safety devices designed and installed in electrical circuits TO PROTECT the conductors [wires] and other components from short circuit conditions and/or overload conditions which cause an extremely large flow of electrical current [measured in Amperes], which causes overheating of the conductors that results in damage to the insulation and the conductors.
And in a worst case scenario, the probability of a FIRE which could destroy the vehicle, house, or other structure in which the circuit is located.
When a fuse or Circuit Breaker [and replacement fuses, or repeatedly "tripping" Circuit Breakers] "blow," especially if it happens repeatedly, is an indication of an UNSAFE CONDITION in that circuit, usually a short.
The fuse or circuit breaker is doing what it was designed, intended, and installed to do; that is to protect the conductors and components of the circuit which it serves.
The proper "fix" for this issue is for a qualified technician, who knows what he or she is doing, to troubleshoot the involved circuit, find and identify the defect, and make proper repair [s], BEFORE replacing the fuse again [with the properly sized fuse or before resetting a circuit breaker].
Some ignorant few people will suggest installing a larger fuse or breaker to solve the problem, BUT that will only increase the hazard, not correct it.
Do not follow "bad" advice by installing a larger fuse in a misguided attempt to correct the problem. To install an oversized fuse would almost guarantee damage to the wiring and the probability of an electrical system fire.
A short in the wiring.
Probably because of the missing insulation from the wire leading from the solonoid on the transmission, causing the bare wire to contact a metal surface, thus creating a short circuit and blowing the fuse.
In the glove compartment fuse box, its fuse position #30 and its a 20 amp fuse.
Fuse Celebrity Playlist - 2006 We Are Marshall 1-26 was released on: USA: 20 December 2006
Fuse Celebrity Playlist - 2006 James Franco 1-1 was released on: USA: 21 September 2006
type in autozone in key word
2006 Ford Focus rear defroster keeps blowing the fuse immediately after replacement
You likely have a frayed wire to the stop light.
no i did not replace head light switch
Are both your brake lights blowing out? If it affects only one light: it could be a bad light socket, or a pinched or frayed wire that is shorting out.
Somewhere between the fuse and the bulb
Fuse, switch, speed resistor or motor.
You likely have a short circuit in the rear light harness somewhere.
There is a short somewhere in the circuit.
1995 Audi A6 Number 8 fuse keeps blowing. Fuse runs domelight, reading light, clock, memory seat, memory side mirror, trunk light. Fuse blow with car just sitting in the drive way parked with key out of ignition. Fuse start to repeatly blow all of a sudden.
brake light fuse 2006 harley softail heritage
Fix the fault blowing the fuse.