answersLogoWhite

0


Best Answer

the necesscity of two three phase Transformers operating in parallel are as follows...

  • if the one transformer fails to give supply,then another transformer can be used in parallel and hance,continuity of supply can be maintained.
  • one transformer can be easily take out from the supply for repair & maintanance.
  • if the load on the substation increases beyond the rated values of transformer, then another transformer can be used to share rhe load of the substation.
User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

A three phase transformer will give you the versatility to run three phase equipment of a specific voltage as well as single phase equipment within the specific voltage range.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why would you use a three phase transformer in place of a single phase transformer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is the current of 1MVA transformer?

This depends on the voltage, and whether it is a three phase or single phase transformer.


Can 3 single phase transformers can replace 1 three phase transformer?

Yes, you can use three single phase transformers on three phase applications and interconnect them to serve as a single transformer or you could use one single phase transformer fed from two of the three lines in a step down application.


Would you install three-phase transformer or bank of three single phase transformer in a large power station and justify by comparing the two schemes?

A three-phase transformer bank is often used in power stations because it is easier to construct and transport very large single-phase transformers, compared with constructing and transforming an equivalent-capacity three-phase transformer.


What will happen if apply two phase supply to a three phase transformer?

A three phase transformer is simply three transformers so, supplying one phase to a set of three transformers will result in only one phase output. Any loads connected to that transformer that are expecting three phase power will malfunction, and could fail.AnswerA three-phase transformer is NOT 'three separate single-phase transformers', as suggested in the original answer. It is a single transformer with three primary and secondary phase-windings wound around a common three-limb ('core') or five-limb ('shell') core. If a single-phase supply was applied to one of the three primary windings, then single phase voltages would appear across each of the three secondary windings and the remaining two primary windings. These voltages would not be out of phase with each other.


How do you design a transformer with three phase 400v input and single phase 2000v output?

By design are you going to wind the transformer yourself? In your design you need a 5:1 ratio. On the output side of the transformer any two legs of a three phase transformer is considered single phase voltage. Good luck on your project.

Related questions

What is this system called with three single phase transformer?

Your question is rather vague. If you are asking what do you call a group of single-phase transformers, connected to supply three phase, then the answer is a 'three-phase transformer bank'.


What is the current of 1MVA transformer?

This depends on the voltage, and whether it is a three phase or single phase transformer.


Can 3 single phase transformers can replace 1 three phase transformer?

Yes, you can use three single phase transformers on three phase applications and interconnect them to serve as a single transformer or you could use one single phase transformer fed from two of the three lines in a step down application.


Would you install three-phase transformer or bank of three single phase transformer in a large power station and justify by comparing the two schemes?

A three-phase transformer bank is often used in power stations because it is easier to construct and transport very large single-phase transformers, compared with constructing and transforming an equivalent-capacity three-phase transformer.


What will happen if apply two phase supply to a three phase transformer?

A three phase transformer is simply three transformers so, supplying one phase to a set of three transformers will result in only one phase output. Any loads connected to that transformer that are expecting three phase power will malfunction, and could fail.AnswerA three-phase transformer is NOT 'three separate single-phase transformers', as suggested in the original answer. It is a single transformer with three primary and secondary phase-windings wound around a common three-limb ('core') or five-limb ('shell') core. If a single-phase supply was applied to one of the three primary windings, then single phase voltages would appear across each of the three secondary windings and the remaining two primary windings. These voltages would not be out of phase with each other.


How do you design a transformer with three phase 400v input and single phase 2000v output?

By design are you going to wind the transformer yourself? In your design you need a 5:1 ratio. On the output side of the transformer any two legs of a three phase transformer is considered single phase voltage. Good luck on your project.


Where does three phase to single phase conversion takes place?

Residential step-down transformers (xxxx to 120volts). Usually a single phase transformer will be used, and connected to one (or possibly two, depending on configuration) of the three phase conductors on the primary side.


How you differentiate between single phase and three phase transformer?

A single-phase transformer works with a single-phase supply, while a 3-phase transformer is used with a 3-phase supply. A single-phase transformer has 2 wires on the primary and secondary (ignoring taps) while a 3-phase tansformer has 3 or 4 wires on the primary and secondary.


Is there a neutral on a three phase transformer?

It depends on whether you are wye or delta connected. A transformer is a transformer, and a three phase transformer is simply three transformers. The key is in how you hook them up.AnswerIt depends on how the transformer is connected. If one set of windings is connected in star (or wye), then the star point is/canbe earthed and becomes the neutral for that particular connection; this is the standard connection for the secondary (low-voltage) of European distribution transformers. In North American three-phase distribution transformers, the secondary windings are connected in delta, and one phase is centre tapped, earthed, and that becomes the neutral point for a 240/120-V split-phase supply to a residence.This answer applies to both three-phase transformers, and to single-phase transformers which have been connected to form a three-phase transformer bank. (It is incorrect to say that a three-phase transformer is simply three single-phase transformers!)


Is there a basic difference between a three phase power transformer and a three phase distribution transformer?

The basic difference is the secondary voltages. On a distribution transformer the secondary voltage is very high. This is to overcome line loss for transmission of electricity over long distances. A three phase power transformer is used at the consumers three phase services end to manipulate voltages that consumers need to operate their equipment. The transformer that feeds your house is considered to be a single phase power transformer.


What is the xo terminal on a transformer used for?

The XO denotes the joined secondary terminal connection of three single coils of a three phase transformer. It is the common return on any unbalanced current of a three phase system.


What will be the output if you apply a single phase on all three wires of supply side of a transformer?

Your question is confusing because you give absolutely no information on the transformer, such as its turns ratio, or any information about the supply voltage. Presumably, though, you are describing a three-phase transformer, as you refer to three wires? Again this is confusing, because you do not describe how you would supply single phase to 'all three wires'!