60Hz generator can be operated at 50Hz as along as certain conditions are met.Basically the problem is that there is a max flux achieveble in any given machine and EA = K(pie)(w) the max allowable E changes when the speed is changed.

Vltage must be derated to 50/60 or 83.3% of its original value. jUst the opposite effect happen when 60Hz generator is operated at 50Hz.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

11y ago

pain ee yako...

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What modifications must be done if 50Hz generator is to be used at 60 Hz?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How you can change a Honda eu10i 60Hz generator to 50HZ?

the generator will have a timing circuit to turn on and off the coil at 60 times per second. you must change the values of the timing circuit to achieve this. definitely need an o-scope and the manufacturer's schematics to accomplish this


How do you connect a 4 wire us 240 volt generator outlet to a 3 wire Australian 240 volt 50Hz plug... Can an adaptor pigtail be made and how do you wire the pigtail?

Yes an adapter can be made. You must keep in mind that the US generator's speed is set for 60 Hz generation. The frequency of a generator is governed by the RPM of the engine. If the generator has speed control on it, it will have to be turned down so that the frequency meter reads 50 Hz.


How do you do modulation BPSK with a digital input the modulation must use matlab simulink?

BPSK Modulation can be done by using a multiplier. Digital data must be multiplied with the carrier frequency. In matlab simulink use a multiplier block to one input apply a sinusoidal generator & to the other a Pulse generator


Can you run a ac unit with a generator?

Yes but some details must be right. The generator must produce the power at the right voltage for the appliances, and it also must be capable of supplying enough power for the appliances.


Why a given generator frequency is dictated by the size of the magnetic flux?

A generator's frequency is dictated by the power system frequency, and the number of poles in the generator. For 60 Hz power and a generator designed with two poles, the generator must turn at 3600RMPs (60 Hz * 60 seconds / minute). The magnetic flux is what induces the current in on the output winding. Spinning a synchronous generator faster or slower is not done to control the magnetic flux. The field winding voltage is varied to control this, and in turn control the output of the generator.


Why is the frequency of a synchronous generator locked into its rate of shaft rotation?

By definition a synchronous generator must be synchronous. If it is not "locked in" it is not a synchronous generator, but an induction machine.


Can client refuse payment to additional jobs he requested done?

that will depend on the contract and the course of business. Many contracts specify that any changes must be in writing. Others allow oral modifications as a matter of course.


How many amps for 1010 KVA generator per phase?

To answer this question the voltage of the generator must be given.


What the Generator lockout relay?

generator lockout relay is a relay that the output of other relays energize this relay and its out put use for tripping of generator. this relay must be reset manually


Is it illegal to build on a historical building?

Yes. If a building is located within an established historical district you must apply for a permit before making any modifications to a building. Historical commissions have the authority to make you reverse any unauthorized modifications and restore the structure to its original condition.Yes. If a building is located within an established historical district you must apply for a permit before making any modifications to a building. Historical commissions have the authority to make you reverse any unauthorized modifications and restore the structure to its original condition.Yes. If a building is located within an established historical district you must apply for a permit before making any modifications to a building. Historical commissions have the authority to make you reverse any unauthorized modifications and restore the structure to its original condition.Yes. If a building is located within an established historical district you must apply for a permit before making any modifications to a building. Historical commissions have the authority to make you reverse any unauthorized modifications and restore the structure to its original condition.


How many amps does a 5500 watt generator uses?

A generator does not use amps it generates amperage. To answer this question the generators voltage must be stated.


Why must you have the numeric and written value on checks?

That makes modifications more difficult, for example, adding a digit.