Q: Can a 2.5 galvanized dielectric union be used to connect black pipe to copper pipe?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you mix black pipe with copper pipe on same low pressure system?

It is not the type of pipe that is important, it is what you are putting through it. Copper is commonly hooked to black pipe for gas lines. Black pipe for natural gas or propane and galvanized for water. Either can have copper attached to them. Due to the electrolytic decay caused by attaching dissimilar metals, you would need to use a dielectric union to connect galvanized steel to a copper pipe; otherwise the joint will rot away in a few years, assuming there is any moisture around the joint. Properly dried gases may not have this problem.


How do you know if you have copper or steel drinking water pipes?

Galvanized pipe will be silver/gray color. Copper will be copper. Use a magnet, it'll stick to galvanized pipe but not to copper. Drinking water lines should not be black steel pipe.


Can brass be galvanized?

IT IS PART Galvanized don't you knowGalvanized is ZINC coating on black steel and YELLOW BRASS piping is 40% ZINC and 60% Copper and RED BRASS is 85% Copper and 15% Zinc=The problem with TOO much Zinc content is dezincification where the piping becomes brittle and to little zinc and the brass is too soft as the higher copper content.==Mixing Galvanized steel and brass or copper causes a condition of electrolytic action as your mixing ferrous metals and non ferrous metals. ( this is first year apprentice training) to prevent the electrolysis one should use a dielectric fitting=


Can you use brass as a dialectric union between copper and black iron pipe?

No, brass cannot be used as a dielectric union between copper and black iron pipe. Dielectric unions are typically made of materials that are not electrically conductive, such as plastic or rubber. Brass is a conductive material and would not provide insulation against galvanic corrosion between copper and black iron pipe.


Can you connect a copper fitting into a cast iron pipe without a dielectric union?

Certainly, if the pipes are kept dry, and don't carry an electrolyte, such as water.Otherwise, it's a bad idea to directly connect different metallic pipes. In fact, most plumbing codes prohibit such a connection.That's because anytime any two dissimilar metals contact each other -- while in the presence of an electrolyte -- whichever metal has the higher electropotential will corrode, through electrolytic action.So, in the case of copper vs iron, the copper side of the joint will eventually fail due to corrosion -- unless you electrically isolate the two metals.You can do this via a dielectric union, or dielectric nipple. Or, you can use a hardened brass fitting, which resists corrosion and also smooths the dielectric potential between the copper and steel.Of course, another author may have a different opinion (like the one below.) So my advice is to understand the 'why' of electrolytic corrosion, so you can determine whether or not, in your case, a dielectric union is advisable.####Of course , NO Problem and there are many ,many options of doing so.The electrolytic conditions happens when connecting ferrous metals to non ferrous metals that contain zinc (galvanized) if you think about it EVERY SINGLE CAST IRON RADIATOR has a brass shut off valve, Most black steel gas line have a BRASS gas valve. Brass bolts are the best way to go when installing CAST IRON ROOF DRAINSAlso why use a dielectric union when there are dielectric nipples less chance of leakage


Can you use black PVC or Quest pipe for natural gas?

NO..copper,black iron, galvanized for gas pipe.never use plasticp solvents or glue.gas does not react well with other chemicals.


How do you connect a electrical outlet at home?

Black wire to copper screw, white wire to silver screw, bare copper ground wire to green ground screw.


Galvanized pipe vs black pipe air service?

Black of course


When running gas on the exterior of the house is it necessary to use galvanized pipe in the city of hayward Calif?

Even though I am in a different country, you should use Black Iron pipe, not galvanized. The other option is copper. Check your local bylaws, GET A PERMIT! This is essential. If you screw up and do not have a permit, you will NOT be covered by insurance!


Is it possible to tell if a painted pipe fitting is black steel or galvanized steel?

without touching it? no what you will have to do is sand or scrape the pipe then you will be able to tell the difference. if its a dull metal then its black iron but if it shines then it would be galvanized.


Is it required to have a dielectric fitting between brass valve and black steel pipe?

No


Is the gold or copper wire or the silver wire positive?

It doesn't really matter, as long as you connect them to the same polarity at both ends. Most people use the gold or reddish-copper wire as the positive, as it is the red terminal and the silver, or non-colored lead to the negative as it is black.