Can a200 amp breaker lug handle a?

Updated: 8/20/2019
User Avatar

Wiki User

12y ago

Best Answer

Handle a "What"?

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can a200 amp breaker lug handle a?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Which terminal on a 15 amp household breaker does the hot wire feed into and which one does it come out?

On a 15 amp household breaker there is no terminal on the in feed of the breaker. The breaker either plugs into the distribution panel's bus bar or it bolts to the distribution's bus bars. The feed conductor connects to the load side of the breaker at its terminal lug.


What equipment is needed to change a car tire?

Make sure you have a jack and a lug nut wrench. Lug nut sizes vary, so make sure you have the correct size! Also, make sure you have the strength to actually tighten or loosen the lug nuts; if you don't, get a "breaker bar" or a tool with a longer handle. This will greatly increase your leverage.


How do you loosen the serpentine belt tensioner?

Place a breaker bar on the lug/hole on the tensioner; then pry against the tensioner.


What size breaker and wire for barn lighing 10 x 60W bulbs and outlets which are 200 feet from main box?

For the lighting load the amperage is A = W/V = 600/120 = 5 amps. As for what will be plugged into the receptacles will be a guess for the calculations. I will give you a full 15 amps for receptacle loads at 120 volts. Total amperage is 20 amps. The breaker for this circuit will be a 20 amp breaker but there may be a problem getting the #6 wire under the breakers terminal connection points. If this is the case use a #6 lug to connect to the breaker and connect the wire into the lug. A #6 copper conductor will limit the voltage drop to 3% or less when supplying 20 amps for 200 feet on a 120 volt system.


How do you install lights on garage that now do not have any?

first run electric cable to garage,10-3 with ground is best,you will have to put at least a 30 amp box in garage more if running 220. if just lights and power tools on 110 then you will be fine!! in box connect red wire to proper lug in box and black wire to proper lug. run 14-2 to lghts!! you can use 12-2 also it is a heavier cable!! at house breaker box run the 10-3 cable to its own breaker in box,at least a 20amp breaker!! red and black wires go to breaker and white goes to neutral bar connect ground to ground bar or neutral bar also!! use a double pole breaker in main box.


Where is the amp in a 94 Ford Explorer?

The factory amp is mounted in the cargo compartment, inside the rear hatch on the immediate left. It is directly across from the jack and lug wrench compartment.


Where is jack handle Toyota Tacoma?

On a 2006 Tacoma the lug wrench has a hex shape appendage on it's side. The lug wrench is thus included in the assembly of extension poles and serves as the handle (moment arm) by which turning force (torque) is applied to the bottle jack.


I have a Transformer 480 primary 208 secondary feeding 1 200amp mb 42 space panel I need to feed a subpanel 6 ft away I'm thinkin feed through lug at top of bus or at feed through MB suggestions?

The sub-panel need to be fed from the main panel, by way of a circuit breaker connected to one of the breaker locations. Or if your sub-panel has a main breaker installed you can feed from the main panel with a sub-feed lug kit. This looks like a breaker, but is only a point where you can branch off the sub panel.


Two black wires attached to a single fuse or breaker lug is what?

Two wires under a common breaker screw is poor electrical workmanship. This usually happens when a "do it yourself" home owner doesn't understand the repercussions of their actions. This problem arises when there is a shortage of breakers to connect a newly installed circuit to. The down side of this installation is that the amount of current is split between two circuits and neither can be used to their full potential. e.g. Two #14 wires fed from one breaker. #14 wire rated at 15 amps. Load on one wire 8 amps, load on the other wire 8 amps, breaker trips. So you can see that you have reduced the maximum capacity of a 15 amp circuit down to 7 amp each. Manufactures recognised this problem and came out with device called a mini breaker. It fits in a standard breaker slot but has two 15 amp outputs. These should only be used when there are no more spare breaker slots left in the panel. Adding more mini breakers only brings the total panel current closer to the main breaker's trip point. If the thoughts of adding more circuits to the panel is in the future, thoughts should be along the line of a new panel change or a service upgrade.


Where is the jack handle and lug wrench on a 2001 Honda Passport?

look under the passenger side cushion on back seat.


How do you install 220 receptacle with white black and bare wires?

Assuming the wires are the correct gauge for application and breaker you use black and white wires as hot. Put red electrical tape on each end of white wire and connect red and black to the breaker output and bare wire to ground lug in panel. At receptacle connect black and red to hot contacts and bare wire to ground lug.


How do you tell the difference between square d 3 pole 50a breaker and square d 3pole 50a breaker with shunt trip?

the easiest way to tell, is the shunt trip breaker will actually take up 4 spaces in your panel. the 4th space will have a neutral wire coming out of it, along with a lug for power INPUT. when voltage is applied to the shunt trip, it will cause the other 3 poles to open by tripping the breaker.