It depends on what your definition of a normal relay is. If it is a small plug in relay to control the motor's contactor then there is no point. All pump motors need control to start and stop the pump. Whether it is done from a pressure switch or a float system it doesn't matter they both should control the motor's contactor and not the pump directly. Most small relays do not have the amp capacity in their contacts to handle inductive loads. Using a motor contactor also has the benefit to protect the motor with overload protection. Using the overload contacts in series with the control device allows the pump to go off line should an overload occur.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you use normal relay to start a single phase motor pump?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is a phase overload relay?

only the single phase monitored at which it installed


3 phase reverse relay can be utilized for motor control speed?

3 phase reverse relay can be utilized to control 480V motor 60HZ for controlling their speedspeed.


Does overload relay detect phase reversing of the 3 phase motor?

No, three phase motor overloads just monitor the motor's lines for an overload. Once detected the circuit holding the magnetic starter in will drop out and take the motor off line.


What is a split phase motor with relay and capacitor called?

A capacitor start motor is a split phase motor that uses a capacitor in series with the start winding to cause a greater phase shift, resulting in greater starting torque. It uses a centrifugal switch to switch out the start winding and capacitor once the motor is up to speed. I assume this switch is what you're referring to as a "relay".


What is phase failure relay?

These relay sense the Negative Sequence Voltage components of system supply & offers protection against Phase Failure, Phase Sequence Reversal with Under/Over Voltage conditions which are dangerous to motor winding and cause motor burnouts.


How star delta helping motor from overheat?

star delta motors start as a Y for 3 phase so the windings that normally see 480 volts see 277V a relay switches to delta then it runs as a normal delta motor the reduces the starting current by about 60% for 3 phase


Can you convert single phase electric motor to three phase connection?

Three-phase motors will run on single-phase power. What they WON'T do is start. There is no easy way to re-wire such a large motor to run on a single phase.Properly sized capacitors and a special relay is sometimes used on sewage lift stations (poopie stations is what we call them) to run the 3-phase pumps on single phase.I've seen 10 hp motors used. Sometimes a lift station is needed where 3-phase power is not available The motor will not develop it's full horsepower, only about 2 thirds. A push-button can be used in place of the relay, but you will have to push the button until the motor starts then let go. If the motor stops you will need to push the button again. Usually expect several hundred micro-farads to be needed.I have used old A/C motor-run capacitors in parallel to experimentally determine the actual size (capacitance) needed. Be sure to use correct working voltage capacitors. DANGER!!! Electricity can EASILY kill you and capacitors can blow up in your face!!!I've seen crazy people attempt to rope-start three-phase motors (it works), connect phase converters, all sorts of weird stuff. In reality, single-phase 5hp motors are available, so the a good recommendation is to trade-in the 3-phase motor for a 1-phase motor of the size you need.To run a three phase equipment from a single phase source, you will need something called a "phase converter".Before you go out and buy one, find out if a single phase motor is available to match your requirements. It will probably be an easier solution for you if you can do that.Depending on your application, another option with such a large motor is to get a "Variable Frequency Drive". These are somewhat expensive but will take in a single-phase input and output 3-phase.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


How can you include phase failure relay in your star delta motor starter circuit?

The star delta motor starter circuit has to have a control voltage to energize the motor magnetic contractors. A phase failure relay monitors all three phases of the incoming supply lines. The phase failure relay also has auxiliary contacts on it. There are usually two sets of "C" form contacts. The control voltage for the starter circuit must be connected across the normally open (N.O.) contacts of one of these two sets. When the phase monitor is energized these N.O. contacts close supplying the control voltage to the circuitry of the star delta starters. If there is a phase interruption, phase reversal or phase loss, the phase failure relay will de-energize and the N.O. contacts will go back to their de-energized state. If the star delta motor starter is in use at the time, its control circuitry voltage will be lost and the delta motor magnetic contactor will open. The opening of this contactor will disconnect the motor from the failed three phase supply.


How do you calculate 3 phase motor overload relay setting?

overload model no Ke-FKR4(D)


What is single phase preventer?

Anti-single phasing relays or single phasing preventer are sometimes required for critical loads and circuits.These are sometimes required because the normal overload protection doesn't trip on time. For large air conditioning compressors, these are sometimes, included.


What is the function of phase sensing relay?

A phase sensing relay monitors all three incoming phase legs at once. With the relay the operator has the ability to set the trip points in a percentage of incoming line voltage. If the voltage in any of the monitored legs falls below the operators set point the relay will trip and take the monitored device off line. If it is a motor being protected, the auxiliary contacts on the phase sensing relay will change state and its N.C. contact will open. The motor's contactor coil is in series with this auxiliary contact so with the stoppage of current flow to the magnetic contactor's holding coil, the contactor opens cutting off the supply to the motor.


How Negative phase sequence relay work?

How Negative phase sequence relay work