answersLogoWhite

0


Best Answer

The wording of this question assumes the low pressure is not associated with a tank problem, or a control box problem.

A few problems can cause low pressure from a submersible pump. The commonest that I've seen is a split in the pipe down the well, or a failed check valve immediately above the pump. ( all sub-pumps have a check valve to prevent 'run back' -these eventually corrode if cheaper types are used ) To fix this, it's necessary to pull up the pump and pipe and physically inspect the pipe, then cut out the split section or check valve and replace it with new parts. -The third, less common problem is the rotor vanes in the 'wet' side of the pump can simply become so eroded and worn that they will no longer pump at high pressure. The fourth, of course is motor failure and this can be determined with an ammeter at the surface. One other and very unusual problem is the sub-pump 'locking up' with silt. -I would rate this as less than 1 % of pump problems - this too can be detected from the surface with an ammeter.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Deep well submersible pump low pressure?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Is 250 considered a deep well or shallow well?

Anything over 80 feet is considered a deep well. A jet pump can pump up from 80 feet, more than that needs a submersible pump.


What is the pressure and gpm for a typical residential water well?

A typical deep submersible pump on a domestic well will be 5-10 gpm and will run up to 120 psi if not governed by a pressure switch at the holding tank. Most Home pressure switches are set to come on at 30-45 psi and shut off at 50-75 psi. This, coupled with the air pressure in the holding tank, means that home pressures of 50 -75 are normal.


How much does it cost to replace well pump?

There are many variables here, so I will answer as best as I can. The pump cost itself depends on whether it's a Shallow Well jet pump, a Deep jet pump or a Deep Well submersible. A shallow jet pump can be found as low as 350 for a reasonable 1/2 hp model that will suck from about 24 feet max. -A deep well jet can suck from 80 feet, and these are seldom less than 550 or so to buy.An average 3/4 hp submersible (which I believe to better in every case, even in shallow wells) will cost you around 750-800 for a good new one. These will pump (rather than suck) from anywhere down to 5-600 feet. I always prefer to use these type of pumps as they are far more reliable, easy to fit and long lasting. -More money to begin with, but a much better deal ! -Other necessities are the drop tube and wire, For tubing I always use 1" polypropylene thick wall tube - about 70 cents per foot. For a submersible also add 14/4 wire which runs about a dollar per foot (all the way down to the pump.) -Wire for a jet pump is negligible as the pump is on the surface.It takes about 5-6 hours labour to fit a deep well sub pump and about 4-5 to fit a jet pump. I don't know where you are, so can't price labour. Here in western Canada it runs 85-105 per hour.Some other tips- Definitely NOT a good idea to use old tubing for the pumpdrop. - If it's a deep well Submersible always change the control box.- If its a jet pump of any type, heat all tubing before connecting and doing up clamps. Most problems with jetpumps start with small air leaks at badly connected tubing. - Alwaysmount a shut off ball valve between jet pump and pressure tank. -You'll see why when you prime it !- Before starting either pump first time, make sure your pressure tank has an adequate air charge !


Why is there no water coming from the well?

Assuming that the pump and the pipes are O.K.then your water level has probably dropped.ANS 2 - It is possible, but unlikely for the well level to drop unless many new people or businesses are sucking from the aquifer you are on. Many things can go wrong with pumps and well pressure tanks. If you have a jet pump (motor and pump on surface) these are very susceptible to air leaks in the pipes to well. Check this. If you have a submersible pump the control box can develop problems. -If you have an old pressure tank it can get 'waterlogged'. If you are unfamiliar with any of this hire a well technician or a local well company to check it out.


What is causing low water pressure in house and pump to constantly buzz in a deep well?

I do not know your situation but a good guess is that your well pump is always on and is not getting enough pressure to shut off the pressure switch. So I would shut off the power to your well pump and see if the buzzing stops and if it does then I would replace your well pump. If the buzzing don't stop with pump shut off then it could still be your well pump check valve slowly leaking threw but I think its your pump because its not pumping enough to shut off with or with out a bad check valve.

Related questions

Where is the pressure switch in a well water supply?

The pressure switch is usually on the pump if it's a jet pump, or at the base of the pressure tank if a submersible pump.


Is 250 considered a deep well or shallow well?

Anything over 80 feet is considered a deep well. A jet pump can pump up from 80 feet, more than that needs a submersible pump.


What is a submersible well pump used for?

A submersible well pump is a pump that is used for pumping water from wells. There are websites that offer submersible well pumps for sale if you need one.


What stands for 150mm submersible pump?

150mm means the well diameter is 150mm, and the well of submersible pump is divided into several specifications. If you want to buy a submersible pump go to VIDO, VIDO's submersible pumps are of high quality and are the choice of most people.


What are the steps in converting deep well water pump to shallow well water pump?

A deep well submersible pump can be simply placed into a shallow well and it will work. These pumps actually pump water directly and do not rely on suction. Simply cut your tube to desired length and place the deep pump in the shallow well. -NOTE- this does NOT work the other way - a shallow or jet pump is just that and can never work in a deep well.


How can I stop a submersible well pump that is constantly running?

You can buy a timed switch mounted on the submersible pump. If you want to buy a submersible pump, you can choose VIDO's submersible pump, VIDO's submersible pump is of high quality and is the choice of most people.


How can you remove submersible pump which was struck in bore-well under 200 feet?

how lift submersible pump stuck 300ft


What are the basic components of residential water well system?

Well, pump, storage tank, pressure switch, pressure gauge, Cycle Stop Valve, tank tee, drop pipe, wire, (with a submersible pump) gate valve and possibly water filtration. bob...


In well water what does it mean if there is sand in your water?

Sand in well water means your pump is sucking it up and will wear out faster. If your pump is submersible, you or a driller can possibly pull it up a few feet. Another option is fitting a "Whirl-a-Way" style filter before the pressure tank.


How much would one expect to pay for a top of the range submersible pump?

Submersible pumps can be purchased at stores such as Home Depot, Canadian Tire as well as Lowe's. A top of the line submersible pump can cost approximately $400 at Home Depot.


What is a Myers Ejecto well pump?

It is what is commonly called a "Jet Pump". This is a motor connected to a pump chamber that has 2 pipes going down the well and sucks water through an 'ejector' that increases flow and brings water to the surface. This pump sits at or near the well head. - The other basic type of well pump is a "Submersible" pump. These sit down the well, deep in water and pump straight to the surface through a series of impellers.


How does a submersible pump work in a water well?

A submersible pump is normally fitted with a float switch. As the water rises, the float switch turns the pump on. When the pump empties the water from the level and the level falls again, the float switch turns the pump off again.