Every bathroom should have its own dedicated 20 amp electrical service breaker. The electrical service breaker should have a surge protector in the case that something electrical falls into water.
read the manufactures data plate on the back of the fridge it will tell you the amps and voltage of the fridge. But most likely will be a 20 amp circuit. code requires min size out lets for stand alone appliances in kitchen to be 20 amp.
A dedicated 20 Amp circuit wired with 12/2 wiring an a 20 amp breaker.
If you are referring to a cloths dryer, the answer depends on the requirements of the dryer. Most dryers require AWG#10 wire with a 30 amp fuse. If the wiring is AWG#12 then use a 20 amp breaker but never use it on AWG#10 which requires a 30 amp breaker. If you are referring to a hair dryer then yes a 20 amp breaker is fine.
No. The two appliances usually have dedicated circuits. The range will have a two pole 40 amp breaker and be fed with a 3-C #8 copper cable. The dryer will have a 30 amp two pole breaker and be fed with a 3-C # 10 copper cable. As you can see by powering a 40 amp device from a 30 amp breaker, full operation of the range will trip the 30 amp breaker.
No, it is not safe to put a 20 amp water pump and a 30 amp water heater on a 50 amp breaker. The total amperage exceeds the capacity of the breaker, which can lead to overheating, tripping, or even a fire hazard. It is recommended to have separate dedicated circuits for each appliance to ensure safety and proper functionality.
The breaker protects the wiring not the boiler. 12,000 watts at 240 volts will require 50 amps. So, you will need a 60 amp breaker using AWG# 6 wire on a dedicated circuit.
No, the whirlpool has a motor load connected to it and should be connected to a dedicated ground fault breaker.
read the manufactures data plate on the back of the fridge it will tell you the amps and voltage of the fridge. But most likely will be a 20 amp circuit. code requires min size out lets for stand alone appliances in kitchen to be 20 amp.
A dedicated 20 Amp circuit wired with 12/2 wiring an a 20 amp breaker.
No, it must be on a dedicated circuit of it's own. It must be on AWG 12/2 wire with 20 amp breaker. It also must be protected with a GFCI outlet.
For a standard size refrigerator, a dedicated 15 amp circuit is used.
A 15 amp dedicated circuit breaker should be used for the dishwasher. The disposal can be wired to the general kitchen 15 amp circuit.
Both a 45 amp and 50 amp breaker would require 6 AWG wire. So if you have 6 AWG wire and any devices like an outlet are rated at 50 amps or greater you are okay.
If you are referring to a cloths dryer, the answer depends on the requirements of the dryer. Most dryers require AWG#10 wire with a 30 amp fuse. If the wiring is AWG#12 then use a 20 amp breaker but never use it on AWG#10 which requires a 30 amp breaker. If you are referring to a hair dryer then yes a 20 amp breaker is fine.
In North America the standard sizes for breakers are 15, 20, 30, and 40 amps. The 15 amp size breaker is used in general circuit wiring. The 20 amp size breaker is used for dedicated appliance receptacles, hot water tank and baseboard heating. The 30 amp size breaker is used for a clothes dryer. The 40 amp size breaker is used for the electric range.
No. The two appliances usually have dedicated circuits. The range will have a two pole 40 amp breaker and be fed with a 3-C #8 copper cable. The dryer will have a 30 amp two pole breaker and be fed with a 3-C # 10 copper cable. As you can see by powering a 40 amp device from a 30 amp breaker, full operation of the range will trip the 30 amp breaker.
A 30 amp electric range typically requires a dedicated 240-volt circuit with a 30 amp breaker and 10-gauge wiring.