In a balanced draft boiler, you actually have both: forced draft (FD) fans supplying air to the furnace, and induced draft (ID) fans removing flue gas. Typically, the FD fans control airflow, while ID Fans control furnace pressure to slightly below atmospheric pressure.
In general though, the choice between forced draft and induced draft is based on how "tight" the system is - if you have leaks, it is better to use ID, as FD will cause product loss.
The procedure for starting draft plant (fans) in a boiler is to start the ID Fan first. Remember that the purpose of the ID Fan is so that the Furnace operates at a slight vacuum. (See Related Link: FD Fan vs ID Fan.) Any casing or furnace leaks then allow air to leak in, rather than allowing air with pulverised fuel and fly ask to leak out.