Best Answer

== == See the View Discussion page by clicking the button shown below this answer. Asking this type of question usually means you aren't ready to do this yourself. If you get any detailed "how to do it" answer here, you might attempt to do something you shouldn't be doing, and that may cost someone a shock, a home fire, or their life. <><><> (LIFE SAFETY WARNING! [disclaimer]

Electricity is dangerous!

You can be injured or killed!

Improper installations can cause fire, injury and death!

Should you be doing this yourself?)

This is one of those questions - if you know this little, you shouldn't be doing what you are planning...

No disrespect intended, but this is SO basic that it suggests you have not studied the subject at all!

THE ANSWERS GIVEN BELOW IGNORE THE MOST VITAL QUESTION THAT MUST BE ADDRESSED:

WHAT ABOUT THE CIRCUIT BREAKERS ON THE MAIN PANEL?

WILL THE EXISTING CIRCUIT BREAKERS PROTECTING THE 240 Volt CIRCUIT BE ABLE TO PROTECT THE NEW 120 Volt OUTLETS?

THAT is why you should not attempt to do this work unless you really know what you are doing.

Better for your own safety - and your family's safety - to give this job to a licensed electrician.

=== === <><><> You need a 4 prong (120/240V) plug to do this. Simply connect the neutral to the neutral bus, the ground to the ground bus, and the two hots to the hot bus bars. Do not tie ground to neutral as you don't have a dedicated ground. Fit your breakers into the panel normally. === === <><><> A 240 outlet doesn't have a neutral which is necessary for this to be done. === === <><><> True, a 220V only outlet does not have the necessary neutral. However, many 220V outlets are 110/220V outlets, such as for dryers or ovens. If it has 4 prongs it will work. If it has 3 it will not, as you need both hots, the neutral, and the ground. == == : IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS. : If you do this work yourself, always turn off the power

at the breaker box/fuse panel BEFORE you attempt to do any work AND

always use an electrician's test meter having metal-tipped probes

(not a simple proximity voltage indicator)

to insure the circuit is, in fact, de-energized.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

Extension cord construction

What comes into play here is the insulation rating of the extension cord. Most cords are rated for 300 volts even though they are only used on 120 volts. As long as the correct 240 volt cord ends are applied to the extension cord it can be used on 240 volts and still be within the limits of the 300 volt insulation factor of the cord.

To allow the cord to carry 30 amps the extension cord has to be constructed from #10 wire. The composition of the cord will have three wires, black, white and green.

To have two 240 volt receptacles on the end of the cord they must be installed in a two gang box. A two gang FS style box would be perfect as it has a hub incorporated into its construction. This hub is needed to take a strain relief connector to secure the cord to the box for safety reasons. This strain relief connector prevents any water from getting into the box through the hub.

If you are constructing an extension cord make sure that the ends go on the right end of the cable. Match the wire end when looking at it, to the proper pin configuration of the plug. A non locking plug will be a 6-30P or a locking plug will be a L6-30P. On a 6-30P plug, black wire to the left blade, white wire to the Y terminal and the green wire to the G terminal. On a L6-30P plug, black wire to the X terminal, white wire to the Y terminal and the ground wire to the G terminal.

Looking at the end of the cable it should be matched to this configuration. If it doesn't look at the other end of the cable. No wires should cross when connecting to the blades on the plug, if they do you have the wrong end of the cable.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you make a 240 volt or 30 amps extension cord with two receptacles?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

How do you make a 30 amp to 15 amp extension cord?

If your extension cord is truly a 30 amp cord then it is composed of #10 wire. #10 wire is rated at 30 amps. All you have to do is remove the 30 amp plug and receptacle ends from the cord and install 15 amp cord ends.


Can you plug a 2 prong extension cord into a 3 prong extension cord?

No, it is not recommended to plug a 2 prong extension cord into a 3 prong extension cord because it can pose a safety hazard. The third prong in a grounded plug provides an extra level of protection, and mismatching them can increase the risk of electrical shock or fire.


How do you use an extension cord to temporarily run the filter?

To temporarily run a filter using an extension cord, make sure the cord is rated for outdoor use and the appropriate length. Plug the extension cord into a nearby grounded outlet and then connect it to the filter. Avoid using indoor extension cords or daisy-chaining multiple cords together to prevent electrical hazards.


Describe three safety rules that deal with the use of extension cords?

Do not overload extension cords by plugging in multiple devices or appliances beyond the cord's capacity. Avoid using damaged extension cords or cords with exposed wires to prevent electric shock or fire hazards. Make sure extension cords are placed in areas where they won't be tripped over or come into contact with water to reduce the risk of accidents.


Why should you not plug a surge protector into an extension cord?

Plugging a surge protector into an extension cord can overload the circuit and increase the risk of a fire hazard due to the excessive energy draw from multiple devices. The extension cord may not be rated to handle the electrical load necessary for a surge protector, leading to overheating and potential damage to the devices connected.

Related questions

Is it acceptable by OSHA to plug an extension cord into another extension cord-?

You can plug an extension cord into another extension cord. A extension cord is to help make doing something easier.


How do you make a 30 amp to 15 amp extension cord?

If your extension cord is truly a 30 amp cord then it is composed of #10 wire. #10 wire is rated at 30 amps. All you have to do is remove the 30 amp plug and receptacle ends from the cord and install 15 amp cord ends.


Can you plug a 2 prong extension cord into a 3 prong extension cord?

No, it is not recommended to plug a 2 prong extension cord into a 3 prong extension cord because it can pose a safety hazard. The third prong in a grounded plug provides an extra level of protection, and mismatching them can increase the risk of electrical shock or fire.


Can you put an extension cord on a treadmill 20 amp?

No, it is not recommended to use an extension cord with a treadmill that requires a 20-amp outlet. Extension cords can overheat and pose a fire hazard when used with high-amperage appliances like treadmills. It's best to have a dedicated outlet installed by a qualified electrician to safely power your treadmill.


Why should you not plug a surge protector into an extension cord?

Plugging a surge protector into an extension cord can overload the circuit and increase the risk of a fire hazard due to the excessive energy draw from multiple devices. The extension cord may not be rated to handle the electrical load necessary for a surge protector, leading to overheating and potential damage to the devices connected.


If your electric lawn mower directions call for a 50 ft ext cord and you use a 100 ft cord what will happen?

Not true, If the motor runs fine on the power cord usually # 14 AWG, good for 15 amps, But a longer cord will usually starve the motor for power, which will make the motor heat up due to the low voltage at the motor, which will litterly burn up the motor, if using a longer cord make it a # 12 AWG, good for 20 amps.


Is there an extension cord wire size and amp rating table?

When purchasing an extension cord it is important to make sure you get one that is large enough to handle the voltage needed. There are some guide lines available through home improvement websites that can help in the buying process.


"Are smoking receptacles made just for outdoors, or do they make indoor ones as well"?

"As far as the stand up smoking receptacles, they are primarilly used outdoors, but they do make some indoor, wall-mounted receptacles as well." The smoking receptacles are normally made for outdoor use.


Will adding a hair dryer to a moped make it faster?

No and I think the extension cord will be a big limiting factor in the driveable range of it as well.


Is there any way such as an extension cord to make a PS3 wired controller cord longer?

There are USB to USB cables (male to female) that should work just fine, available in various lengths.


How do you wire single phase 240V extension cord with five wires to female-male plugs having four wiring points?

You can wire a single phase 240V extension cord with five wires to a female-male plug with four wiring points by connecting the two hot wires (usually black and red) together to the plug's gold or brass terminals for the hot connection, and connecting the neutral wire (usually white) to the silver terminal on the plug. The extra wire could be a ground wire (usually green or bare copper) which connects to the plug's green screw for grounding the extension cord. Make sure to follow safety precautions and guidelines for proper connections.


How do you create a male to male extension cord?

Dont make a male to male cord! The reason is you will have a energized male end when you plug into a socket. Call a electrican to help you with your project Dont make a male to male cord! The reason is you will have a energized male end when you plug into a socket. Call a electrican to help you with your project