zma da ghan mata sa raze
Even if I do not understand the language used above I still believe that the answe above is very irrelevant, to say the least.
Answer:
1. Resistance start single phase motor
2. Capacitor start single phase motor
3. Capacitor start and run single phase motor
4. Capacitor start capacitor run single phase motor
split phase induction motor,capacitor start induction motor
A balanced three phase system is composed of three single phase voltages having the same amplitude and frequency but displaced from one another by 120 degrees (1/3 cycle).We know that a single coil (winding) rotating in a magnetic field produces a single phase alternating voltage. Similarly, three phase voltage can be produced by a set of three coils separated from each other by 120 electrical degree. Three phase power is so popular because of following advantages.For a given size of frame, a three phase generator or motor has a bigger output than a single- phase machine.To transmit a given amount of power at a given voltage over a given distance, a three phase transmission line requires less copper than a single phase line.Three phase motors are self starting; single phase motors are not self startingParallel operation of three phase alternators is simpler than that of a single phase alternators.
Yes. This is often done in distribution boards.
If single phase - 2 wire service > two wires If single phase - 3 wire service > three wires If three phase - 3 wire service > three wires If three phase - 4 wire service > four wires US residential service is usually single phase 3 wire service: Two hots and neutral.
simply four but also aplying diversity they may be increased depending on situation
Yes, if the motor is rated 240 volts 3 phase.There is such a thing as 240 volt 3 phase power.However if you are asking if you can use 240 volts single phase on a three phase motor, then the answer is no.
480 Volt
A balanced three phase system is composed of three single phase voltages having the same amplitude and frequency but displaced from one another by 120 degrees (1/3 cycle).We know that a single coil (winding) rotating in a magnetic field produces a single phase alternating voltage. Similarly, three phase voltage can be produced by a set of three coils separated from each other by 120 electrical degree. Three phase power is so popular because of following advantages.For a given size of frame, a three phase generator or motor has a bigger output than a single- phase machine.To transmit a given amount of power at a given voltage over a given distance, a three phase transmission line requires less copper than a single phase line.Three phase motors are self starting; single phase motors are not self startingParallel operation of three phase alternators is simpler than that of a single phase alternators.
Most electrical equipment are either designed to work on Single phase (two wires) or Three Phase (three or four wires). Two phase equipment are non existent today. A single phase heater will require a single phase thermostat while a three phase heater will require a three phase thermostat.
Delta motors should have more starting current than Wye (Star) motors because Delta motors have two windings to take current per phase -- they are wired Phase to Phase. Star motors have only one winding per phase -- they are wired Phase to Neutral.
Yes. This is often done in distribution boards.
In a three phase four wire system - voltage between any one phase and the neutral is single phase. Hence the single phase equipment or load between any one phase and the neutral.Another AnswerA single-phase load can be connected either between any line conductor and the neutral conductor, or between any pair of line conductors. The choice is dependent on the voltage rating of the load, which must match either the phase voltage (line-to-neutral) or line voltage (line-to-line) -these values will be indicated on the machine's nameplate.
3600 rpm
It depends on where you live in the world. In North America there are two types of services, single phase and three phase. Single phase is usually used in homes and three phase is used for commercial and industrial installations. Single phase home services are 120/240 volts and can be identified by there being three wires coming to your home and into the service head drop. Three phase services are now usually a wye connection and are identified by there being four wires that go into the service head. These voltages could be 120/208, 277/480 and 347/600.
A two-phase a.c. system is an archaic system, in which two phase voltages are generated 90 electrical degrees apart. It has nothing whatsoever to do with the US 'split phase' system that supplies North American homes. A two-phase system can be a four-wire system, or a three-wire system, and was useful because, unlike a single-phase system, it could create naturally rotating magnetic fields in induction motors. It has long been superseded by the three-phase system.
Let's get the terminology correct. A 'phase voltage' is measured across a phase, whereas a line voltage is measured between two lines. So there is no such thing as a 'phase to phase' voltage -it's a line to line voltage (hence the term 'line voltage').
If single phase - 2 wire service > two wires If single phase - 3 wire service > three wires If three phase - 3 wire service > three wires If three phase - 4 wire service > four wires US residential service is usually single phase 3 wire service: Two hots and neutral.
Single phase 220 V AC(measured Across the line and Neutral) Three wire system having one Live(L),one Neutral(N),one ground's. Two wire system having one Live(L),one Neutral(N). Two phase 220 V AC (measured Across the two phases i.e across Phase RY or across Phase YB or across Phase BR) . Three wire system having tow live (L), one Ground (G). Two wire system having two Live(L). Ramesh P