Q: What if Suction side of condensing unit has ice on it?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Is there a reason why you would have ice build up around the pipes for your air conditioner?

Several things can cause this. A clogged filter, bad/dirty blower, dirty fins on outdoor condensing unit or the fan in the outdoor condensing unit not running or not running properly can all cause poor air flow and cause ice on the pipes. Low coolant level can also cause this. So, try the easy things like cleaning it and changing the filter first and see if that helps. If it doesn't, a tech will probably have to come out to recharge the unit and look for a leak.


Why would a suction line ice up?

Its due to the refrigerant dropping to a temperature that's below freezing(32 degrees at sea level) and the humidity(water) that forms on the suction line freezes caused by several things: shortage of freon, dirty evaporator coil, oversized unit, and dirty filter.


What causes refrigerant side of water cooled chiller to have excessive suction and discharge pressure though tubes are clean?

Goldfish. They get in at night, have underwater cocktail parties and leave the ice floating about.


What cause ice formation on suction lines of the compressor?

The system and the load have become imbalanced. It will need to be looked at as the possible causes are many.


How cold should be copper lines on ac unit?

There is no real set temp for the lines ,the bigger thing is the heat that the outside unit is producing when the unit is on. A normal functional AC unit will be around 105 to 110 degrees as for the copper lines they should feel pretty cold to the touch like an ice colds beer feels in your hand......

Related questions

If the suction side of the condensing unit has ice on it what does this mean?

Unit is not cooling properly due to loss of capacity... Usual causes: air flow restricton dirty filter or evaporator coil, loose or broken indoor fan belt, indoor fan on too low a speed setting, if it has always been present undersized ductwork should be investigated or the system is low on refrigerant.


Make a sentence with the word condensing?

Condensation was forming on the side of the ice cold glass of soda.


Is there a reason why you would have ice build up around the pipes for your air conditioner?

Several things can cause this. A clogged filter, bad/dirty blower, dirty fins on outdoor condensing unit or the fan in the outdoor condensing unit not running or not running properly can all cause poor air flow and cause ice on the pipes. Low coolant level can also cause this. So, try the easy things like cleaning it and changing the filter first and see if that helps. If it doesn't, a tech will probably have to come out to recharge the unit and look for a leak.


Why compressor suction line ice forming in a refrigeration system?

air contains moisture & suction line is very cold both in contact moisture turns into ice. just a joke


Can suction cups stick to ice?

I think so but I'm not sure


Why is water condensing a physical change?

Because it become solid. Example water become ice.


Why would a suction line ice up?

Its due to the refrigerant dropping to a temperature that's below freezing(32 degrees at sea level) and the humidity(water) that forms on the suction line freezes caused by several things: shortage of freon, dirty evaporator coil, oversized unit, and dirty filter.


What causes refrigerant side of water cooled chiller to have excessive suction and discharge pressure though tubes are clean?

Goldfish. They get in at night, have underwater cocktail parties and leave the ice floating about.


Is melting of ice a physical process?

Yes, changes of state (melting, boiling, freezing, condensing) are physical processes.


How does it called when water gas come to solid type of water?

Sublimation, (condensing dry to ice), hoar-frosting (climatologic)


What is water vapor deposition?

Water vapour depostion is water vapour transforming directly to ice without condensing first.


Why is your HVAC unit outside freezing in the winter?

Your unit is freezing up out side like a block of ice? if so then obviously you have a heat pump.. what is happenong is your defrost board or thermostat on the out side unit is no good and needs to be replaced.. if you cant afford service on it, to defrost the unit some what quickly, turn your air conditioner on for abour 5 minutes.. that should defrost the unit..