Q: Where can one find a neutral connection point?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Diagram of star-delta connection of motor?

Unfortunately, WikiAnswers does not support graphic images, so I will have to describe the connection in words. There are three windings, each with two wires. That is six connections. There are four connections in a star (wye) source, three hots and a neutral. The star connection has one end of all three windings connected (together) to neutral and the other ends connected to each hot. The delta connection has each winding connected end-to-end to each other in a ring, and each common point is connected to a hot. Neutral is not used in delta.


On a stup down transformer what does the xo symbol mean?

On a step down transformer XO symbol denotes the secondary split phase grounding point. This is also where the neutral of the three wire secondary is connected. The transformer connection is known as a single phase - three wire - with one secondary winding.


What is the difference between star delta and wye delta?

With a delta connection, picture a triangle. Each side of the triangle is a transformer or motor winding. Call the 3 corners of the triangle A, B, and C. There are only 3 wires except for a safety ground, which has no connection to, nor is any part of, the power transmission service lines.but for the star connection take our triangle above and use your wire cutters (literally) to cut the triangle apart at the corners. rearrange the three sides (transformer or motor windings) to form a Y. Where the three sides join in the centre, connect a fourth wire. Call this wire "neutral". Call the three ends A, B, and C. Connect the 3 supply service lines to A, B, and C.


Why cant take connection from phase line to neutral line?

A connection can be taken between phase lines, or between one phase and neutral. Both methods give a single-phase supply. Between phases the voltage is sqrt(3) times more than between one phase and neutral. In each case the load gives an unbalanced current on the 3-phase system but the idea is to average out the unbalances over a group of single-phase loads.


What is the difference between ground and floating neutral in your electric panel?

Neutral is vital to complete the cicuit. Ground is vital to carry the current to earth during a malfuntion of the appliance using power to drive it, should the current come in contact with the frame or outer covering of the appliance and endangering the users life.

Related questions

Why neutral is ground in the circuit?

In the transformer at the secondry side one end of the winding will make star connection means 0 point there will be no voltage at that end if any leake voltage appear at that point it have to ground that what all the neutral points to be grounded


How can you how can you detect wye from delta with neutral connections?

The star connection has three phase terminal leads and one neutral lead. In case of delta connection it has got three phase terminal leads. the star connection is generally represented by Mercedes symbol with neutral line drawn from the mid point. The delta is represented like a triangle symbol with noneutral line shown.


How is the neutral point in a star connection created?

In a distribution transformer's star-connected secondary, the common point of connection is called the 'star point' and is connected to earth. The star point then provides the neutral connection for the transformer secondary, providing a return path for any unbalanced currents due to an unbalanced three-phase load.This arrangement provides a four-wire distribution system, comprising three line conductors and one neutral conductor (in addition, there are various methods of providing an earth connection to consumers). The line-to-line voltage is called a line voltage (in the UK, 400 V), while a line-to-neutral voltage is called a phase voltage (in the UK, 230 V). The line voltage being 1.732 x phase voltage.


Which thoughts and feelings have you assume there's no point of living due to a bad life?

Life is valuable regardless. It can be lived to be bad, but overall one must find a connection, or the connection between themselves and God. There is only one connection.


It is defined as the common reference point in an electric circuit from which voltage is measured?

A Neutral, Common, or Ground.


How can you get wifi to work on a Pokemon game?

You'll need the Access Point first and then you can get WiFi Connection. Search for a Access Point in the WiFi Connection Settings and look for one around in the house. (Usually by windows.) Once you do find one (that is unlocked) you can connect to it and you can use the WiFi.


Diagram of star-delta connection of motor?

Unfortunately, WikiAnswers does not support graphic images, so I will have to describe the connection in words. There are three windings, each with two wires. That is six connections. There are four connections in a star (wye) source, three hots and a neutral. The star connection has one end of all three windings connected (together) to neutral and the other ends connected to each hot. The delta connection has each winding connected end-to-end to each other in a ring, and each common point is connected to a hot. Neutral is not used in delta.


Why are you getting 120 volts from hot wire and grounded rod?

On a North American electrical distribution system this is quite normal and natural. The neutral connection point in a distribution panel is connected to the ground rod via the ground wire. So in effect the ground rod and the neutral are one in the same.


On a stup down transformer what does the xo symbol mean?

On a step down transformer XO symbol denotes the secondary split phase grounding point. This is also where the neutral of the three wire secondary is connected. The transformer connection is known as a single phase - three wire - with one secondary winding.


Why does delta connection have no neutral connection?

Lets compare between a star and delta connection in 3-phase power types. In a star connection, there are 6 connections (A1, B1 and C1 being the outer arms of the 3 armed star and at the centre, A2, B2 and C2). The center is called the neutral or star point which carries out the any unbalanced current loads through its connection. That is why if you lose out the neutral point in a star connection, there will be an overflow of current through to the loads. The loads also take in more current, generating much more power and could damage the appliance you are using and the components the line current is connected to, since excess heat and overworking may result.In a delta connection, the connection has only 3 and on a piece of paper it is sketched as the connections being joined arm to arm. One side is A phase, B phase and C phase. Getting to the point, a Delta connection does not have a earth wire because the live voltage is always the same throughout the connection. Since phase and line voltage are the same and constants. It also means the line current will change without affecting other components within the circuit. Balanced Delta connected circuits or loads can only have their power supply sourced from a star connection and a balanced Star load can only have their voltage supply come from a delta connection.Another AnswerWith a delta connection, the phasor sum of the three line currents is zero, whether the load is balanced or unbalanced, so no neutral is necessary.


Is one-sided and therefore lacks a neutral point of view?

i do not know it is life


What is the difference between star delta and wye delta?

With a delta connection, picture a triangle. Each side of the triangle is a transformer or motor winding. Call the 3 corners of the triangle A, B, and C. There are only 3 wires except for a safety ground, which has no connection to, nor is any part of, the power transmission service lines.but for the star connection take our triangle above and use your wire cutters (literally) to cut the triangle apart at the corners. rearrange the three sides (transformer or motor windings) to form a Y. Where the three sides join in the centre, connect a fourth wire. Call this wire "neutral". Call the three ends A, B, and C. Connect the 3 supply service lines to A, B, and C.