answersLogoWhite

0

a pipette is more accurate than a graduated cylinder due to allowing a greater amount of control on how much fluid you want. With a graduated cylinder, you pour the fluid into it, and risk accidentally pouring in too much or not enough, causing you to have to pour some out or add still more.

With a pipette, the control mechanism (depends on type of pipette), allows far greater control over how much and how fast you want to add fluid. Any errors therefore, tend to be smaller and easier to remedy.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Chemistry

What is more precise a pipette or graduated cylinder?

A pipette is generally more precise than a graduated cylinder. This is because pipettes are designed to deliver specific volumes of liquid accurately, while graduated cylinders are typically used for measuring approximate volumes.


Why is a volumetric pipette more accurate than a graduated pipette?

Graduated pipettes are not as accurate as volumetric pipettes, because each graduation line is not individually calibrated, and any imperfection in the internal diameter will have a greater effect on the volume delivered. In volumetric pipettes, the diameter of the pipette where the graduation mark is located is significantly smaller because the majority of its volume is located in the bulb.


How to properly read a serological pipette for accurate measurements?

To properly read a serological pipette for accurate measurements, follow these steps: Hold the pipette vertically and at eye level. Check the calibration marks on the pipette to ensure it is the correct volume. Align the meniscus (the curved surface of the liquid) with the desired calibration mark. Read the volume at the bottom of the meniscus for an accurate measurement. Make sure to account for any liquid clinging to the walls of the pipette. By following these steps, you can ensure precise and accurate measurements when using a serological pipette.


Why is measuring pipette better than transfer pipette?

A measuring pipette is used to measure specific amounts of liquid. There are many different kinds but they help you accurately measure and transfer small amounts. A transfer pipette is essentially an eye-dropper, they typically do not have measurements on them.


Why can sulphuric acid be added with a measuring cylinder instead of a pipette?

Sulfuric acid is highly corrosive, so it can be added using a measuring cylinder because it is more resistant to the acid's corrosive properties compared to a pipette. Using a measuring cylinder allows for easier and more accurate measuring of larger volumes of sulfuric acid compared to a pipette.

Related Questions

Who among the following is the more accurate in measurement the pipette or the volumetric pipette?

Theoretically a graduated cylinder...but if the only graduate I've got holds five liters with graduations 100 ml apart and I'm trying to measure to the milliliter, the pipette would be more accurate.


Why pipette is more accurate when determine the density of water?

A pipette is more accurate for measuring the volume of water because it allows for precise and controlled dispensing of liquid in small, measurable increments. The accuracy of the pipette ensures that the volume measurement is consistent, leading to more accurate calculations of density. Additionally, using a pipette reduces the chances of human error when transferring and measuring the water sample.


What would you use to measure volume?

It depends on the amount you want to take. If it is microlitres, you can use a micropipette, millilitres, a pipette (a burette would be more accurate), and if greater than that, it is best to use a large graduated cylinder. A graduated cylinder is more inaccurate than a pipette, but at volumes of 500ml for example, it is impractical to use a pipette.


What is more precise a pipette or graduated cylinder?

A pipette is generally more precise than a graduated cylinder. This is because pipettes are designed to deliver specific volumes of liquid accurately, while graduated cylinders are typically used for measuring approximate volumes.


Why is a volumetric pipette more accurate than a graduated pipette?

Graduated pipettes are not as accurate as volumetric pipettes, because each graduation line is not individually calibrated, and any imperfection in the internal diameter will have a greater effect on the volume delivered. In volumetric pipettes, the diameter of the pipette where the graduation mark is located is significantly smaller because the majority of its volume is located in the bulb.


Why burrete more accurate than pipette?

Burette is more accurate than a pipette because burettes are designed with a high degree of precision and have graduations that allow for very accurate volume measurements. Burettes also allow for easy adjustment and control of the volume being dispensed. Additionally, burettes are typically used for larger volumes compared to pipettes, further enhancing accuracy.


What is a Mohr Pipette used for in chemistry?

A Mohr pipette is a type of pipette that measures the volume of dispensed liquids. It is less accurate compared to a volumetric pipette.


How to calibrate a pipet for accurate measurements?

To calibrate a pipette for accurate measurements, first ensure it is clean and dry. Then, use a calibrated balance to weigh the water dispensed by the pipette. Compare the measured weight to the expected weight based on the pipette's specifications. Adjust the pipette as needed to ensure accurate measurements.


How do you properly calibrate a pipette for accurate measurements in the laboratory?

To properly calibrate a pipette for accurate measurements in the laboratory, follow these steps: Check the pipette for any visible damage or contamination. Use a calibrated balance to weigh the water dispensed by the pipette. Compare the measured weight to the expected weight based on the pipette's specifications. Adjust the pipette if there is a discrepancy by following the manufacturer's instructions for calibration. Repeat the calibration process until the pipette consistently delivers accurate measurements.


Why should I calibrate my pipette and what are the benefits of doing so?

Calibrating your pipette ensures accurate and precise measurements, which is crucial in scientific experiments where even small errors can lead to inaccurate results. By calibrating your pipette, you can trust that your measurements are reliable, leading to more accurate data and better experimental outcomes.


How to calibrate a pipette for accurate measurements?

To calibrate a pipette for accurate measurements, follow these steps: Check the pipette for any visible damage or contamination. Set the pipette to the desired volume. Use a calibrated balance to weigh the water dispensed by the pipette. Compare the measured weight to the expected weight for the volume dispensed. Adjust the pipette as needed to ensure accurate measurements. Repeat the calibration process regularly to maintain accuracy.


How to properly read a serological pipette for accurate measurements?

To properly read a serological pipette for accurate measurements, follow these steps: Hold the pipette vertically and at eye level. Check the calibration marks on the pipette to ensure it is the correct volume. Align the meniscus (the curved surface of the liquid) with the desired calibration mark. Read the volume at the bottom of the meniscus for an accurate measurement. Make sure to account for any liquid clinging to the walls of the pipette. By following these steps, you can ensure precise and accurate measurements when using a serological pipette.