A circuit breaker is a device that opens its contacts in order to open the circuit in case of current overload. A differential circuit breaker is a device that opens the circuit in case of leakage (current measured on the phase line is differentthan the current returned to neutral line); therefore protects users from electric shocks.

To more understand how it operates, consider the following:

Say that your electrical wall outlet is connected to a differential breaker. When plugging let's say a hair dryer to it, the current traveling on the phase line (going into the hair dryer and out to the neutral line of the wall outlet) equals but in reverse direction of the current returned to the neutral line, thus the difference is zero. Now let's say this hair dryer got faulty and fraction of the current coming from the outlet phase line travels through your body and return to earth (considering that you are not electrically isolated from the ground). Thus the current in neutral line is less than the current on phase line; at this moment the difference is not zero and breaker opens to protect you from getting electrocuted.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

11y ago

A residual current device is a device whose purpose is to disconnect a circuit when it detects that the flowing electricity is not balanced between the conductor and the return neutral conductor

It combines the functions of overcurrent protection and leakage detection.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the difference between a differential circuit breaker and a circuit breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the difference between fuse and MCB?

what is the difference between miniature circuit breaker and fuse


What is the difference between rated short circuit duration 3 seconds and 1 second circuit breaker?

The energy dissipated.


What is difference between VCB and ACB?

VCB (vacuum circuit breaker) is used in HV (high voltage) applications. ACB (air circuit breaker) is used in LV (low votage) applications.


What is the difference between ITE and FPE circuit breaker?

The connection blades and how they connect into the distribution panel's bus.


What is the difference between a run and a circuit?

run in a electrical system means a wiring & conduit runs coming from Panel Board Circuit Breaker to its branch circuit loads in a circuit. while circuit is a designated number of branch breaker in a panel board where power load was individual connected.


What are the difference MCB and CB?

The main difference between MCB, RCCB, and Isolators Isolators are generally used in power system while on the other hand, MCB is the circuit breaker. Isolators are manually-operated device, and on the contrary, the circuit breaker is the automatically-operated device.


What is the difference between 16A TP and 16A TPN isolator?

The difference between 16A TP and 16A TPN isolator is the type of the circuit breaker that is used. The terminal design is the other difference.


What is the difference between thermal magnetic release circuit breaker microprocessor based release circuit beraker?

As far my knowledge goes the only difference i found in a thermal magnetic relase & microprocessor based was in a microprocessor based Circuit breaker we have a additional protection i.e. for Earth fault. Aparts that the range of fault setting in a microprocessor based circuit breaker is more than in a thermal magnetic trip unit.


How does a vacuum circuit breaker operate?

In a vacuum breaker the moving contact and fixed contact are sealed inside a vacuum chamber. Electrons cannot flow in a vacuum, therefore as soon as the moving contact seperates from the fixed contact the arc meets an infinite resistance and is immediately extinguished. Because of this, the gap between the fixed and moving contacts when the breaker is open need only be a tiny amount.


What is the difference between Draw-out and Fixed-air circuit breaker?

A drawout breaker has two parts (base and breaker). The base is wired to the load frame and bolted in. The breaker slides in and out of the base, and connects physically and electrically to the base (so it's easy to rack out for maintenance). A fixed mounted circuit breaker is bolted directly to the enclosure and wired to the load frame.


What is a Circuit breaker and explain type circuit breakers?

A circuit breaker is a switching device which can make,brake and carrying (or trip the circuit) that specified over currents for a small interval of time . There is a different types of Circuit Breaker's are there 1.According to their arc quenching media these are divided into 4 types a) Oil circuit breaker b) Air blast circuit breaker c) SF6 circuit breaker d) vacuum circuit breaker 2. According to their services the circuit breaker can be divided as a) Outdoor Circuit Breaker b) Indoor Breaker 3. According to the operating mechanism of circuit breaker they can be divided as a) Spring operated Circuit Breaker b) Pneumatic Circuit Breaker c) Hydrolic Circuit Breaker 4. According to the voltage level of installation these are divided into 3 types a) High Voltage Circuit Breaker b) Medium Voltage Circuit Breaker c) Low Voltage Circuit Breaker.


What is difference between the mcb and rcb?

MCB stands for miniature circuit breaker , which provides protection against over current. the setting is not adjustable. RCB stands for residual circuit breaker which provides protection against earth fault as well as over current. It monitors the current difference between phase and neutral and if the difference is more than rated value say 200 milli amps it will trip.