Want this question answered?
The Nyquist Therorem states that the lowest sampling rate has to be equil to or greather than 2 times the highest frequency. Therefore the sampling rate should be 400Hz or more.
It states that for satisfactory representation of the sampled signal the sampling frequency must be atleast equal to twice the highest input freq, which is called nyquist sampling. If its less than twice, undersamplin occurs resulting in distortion.
A 20Hz signal must be sampled at a minimum of 40Hz to have a chance of sampling both peaks and to get a reasonable representation it must be sampled at a minimum of 100Hz.For a sampling rate of 30Hz the Nyquist frequency is 15Hz and since 20Hz is above that it will generate the alias signal of 10Hz in the sampled data instead of the original signal of 20Hz. Therefore it is not possible to do what you ask.
>8000hz
Sampling rate or sampling frequency defines the number of samples per second (or per other unit) taken from a continuous signal to make a discrete or digital signal.
According to Niquest Theorem, it has to be more than twice the input frequency.
As we know that the sampling rate is two times of the highest frequency (Nyquist theorm) Sampling rate=2 Nyquist fs=8000hz/8khz
The Nyquist Therorem states that the lowest sampling rate has to be equil to or greather than 2 times the highest frequency. Therefore the sampling rate should be 400Hz or more.
It states that for satisfactory representation of the sampled signal the sampling frequency must be atleast equal to twice the highest input freq, which is called nyquist sampling. If its less than twice, undersamplin occurs resulting in distortion.
A: A sampling scope is not real time scope but rather a hi frequency rate of sampling which benefit the observer
A 20Hz signal must be sampled at a minimum of 40Hz to have a chance of sampling both peaks and to get a reasonable representation it must be sampled at a minimum of 100Hz.For a sampling rate of 30Hz the Nyquist frequency is 15Hz and since 20Hz is above that it will generate the alias signal of 10Hz in the sampled data instead of the original signal of 20Hz. Therefore it is not possible to do what you ask.
The Nyquist frequency should not be confused with the Nyquist rate, which is the minimum sampling rate that satisfies the Nyquist sampling criterionfor a given signal or family of signals. The Nyquist rate is twice the maximum component frequency of the function being sampled. For example, the Nyquist rate for the sinusoid at 0.6 fs is 1.2 fs, which means that at the fs rate, it is being undersampled. Thus, Nyquist rate is a property of a continuous-time signal, whereas Nyquist frequency is a property of a discrete-time system.When the function domain is time, sample rates are usually expressed in samples/second, and the unit of Nyquist frequency is cycles/second (hertz). When the function domain is distance, as in an image sampling system, the sample rate might be dots per inch and the corresponding Nyquist frequency would be in cycles/inch.
>8000hz
Sampling rate or sampling frequency defines the number of samples per second (or per other unit) taken from a continuous signal to make a discrete or digital signal.
The sampling rate must be at least double the highest frequency component of the modulating signal in order to avoid frequency aliasing.
frequency is simply the rate at which something is happening, ie the frequency of Christmas is once a year, the frequency of having breakfast is once a day etc. If frequency is expressed in Hertz, it's how many times something happens during a second. Sampling is, well, sampling. Usually means testing and measuring something changeable. If you're running a bath and occasionally stick your fingers in to check the temperature, then that's sampling, Sampling frequency simply describes at which rate you're making whatever test or measurement it is you're talking about.
not sure what your asking, but if you are asking what i think your asking, you have to sample at least at twice bandwidth of the frequency you are sampling. This is known as Nyquist Rate http://en.wikipedia.org/wiki/Nyquist_rate