answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What is the minimum sampling rate if the input frequency is 3 kHz?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering
Related questions

What is the highest sampling rate if the input frequency is 3 kHz?

According to Niquest Theorem, it has to be more than twice the input frequency.


What uis the sampling rate for PCM if the Frequency ranges from 1000 to 4000 Hz?

As we know that the sampling rate is two times of the highest frequency (Nyquist theorm) Sampling rate=2 Nyquist fs=8000hz/8khz


If the frequency spectrum of a signal has a bandwidth of 500 Hz with the highest frequency at 600 Hz what should be the sampling rate?

The Nyquist Therorem states that the lowest sampling rate has to be equil to or greather than 2 times the highest frequency. Therefore the sampling rate should be 400Hz or more.


What is sampling thearm cocerning the rate of sampling required for analog signal?

It states that for satisfactory representation of the sampled signal the sampling frequency must be atleast equal to twice the highest input freq, which is called nyquist sampling. If its less than twice, undersamplin occurs resulting in distortion.


How does the sampling oscilloscope increase the appearent frequency response of an osciloscope?

A: A sampling scope is not real time scope but rather a hi frequency rate of sampling which benefit the observer


How is it possible to represent a complex exponential signal with a frequency of 20Hz using a sampling frequency of 30Hz?

A 20Hz signal must be sampled at a minimum of 40Hz to have a chance of sampling both peaks and to get a reasonable representation it must be sampled at a minimum of 100Hz.For a sampling rate of 30Hz the Nyquist frequency is 15Hz and since 20Hz is above that it will generate the alias signal of 10Hz in the sampled data instead of the original signal of 20Hz. Therefore it is not possible to do what you ask.


How would you define nyquist rate?

The Nyquist frequency should not be confused with the Nyquist rate, which is the minimum sampling rate that satisfies the Nyquist sampling criterionfor a given signal or family of signals. The Nyquist rate is twice the maximum component frequency of the function being sampled. For example, the Nyquist rate for the sinusoid at 0.6 fs is 1.2 fs, which means that at the fs rate, it is being undersampled. Thus, Nyquist rate is a property of a continuous-time signal, whereas Nyquist frequency is a property of a discrete-time system.When the function domain is time, sample rates are usually expressed in samples/second, and the unit of Nyquist frequency is cycles/second (hertz). When the function domain is distance, as in an image sampling system, the sample rate might be dots per inch and the corresponding Nyquist frequency would be in cycles/inch.


What is the sampling rate for PCM if the Frequency ranges from 1000 to 4000 Hz?

>8000hz


What is sampling rate in audio digitization?

Sampling rate or sampling frequency defines the number of samples per second (or per other unit) taken from a continuous signal to make a discrete or digital signal.


What is the relationship between sampling rates and frequency of the modulating signal when using pulse modulation?

The sampling rate must be at least double the highest frequency component of the modulating signal in order to avoid frequency aliasing.


What is the difference between sampling frequency and frequency?

frequency is simply the rate at which something is happening, ie the frequency of Christmas is once a year, the frequency of having breakfast is once a day etc. If frequency is expressed in Hertz, it's how many times something happens during a second. Sampling is, well, sampling. Usually means testing and measuring something changeable. If you're running a bath and occasionally stick your fingers in to check the temperature, then that's sampling, Sampling frequency simply describes at which rate you're making whatever test or measurement it is you're talking about.


If sampling frequency doubles then?

not sure what your asking, but if you are asking what i think your asking, you have to sample at least at twice bandwidth of the frequency you are sampling. This is known as Nyquist Rate http://en.wikipedia.org/wiki/Nyquist_rate